Angioscopic findings of the neointimal coverage over the sirolimus-eluting stent: Nine-months follow-up study

被引:0
|
作者
Awata, M [1 ]
Kotani, J [1 ]
Nanto, S [1 ]
Uematsu, M [1 ]
Morozumi, T [1 ]
Onishi, T [1 ]
Iida, O [1 ]
Oshima, F [1 ]
Minamiguchi, H [1 ]
Akahori, H [1 ]
Nagata, S [1 ]
机构
[1] Kansai Rosai Hosp, Amagasaki, Hyogo, Japan
关键词
D O I
暂无
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
引用
收藏
页码:27B / 27B
页数:1
相关论文
共 50 条
  • [1] Angioscopic findings of neointimal coverage over sirolimus-eluting stents: One year follow-up study
    Awata, Masaki
    Kotani, Jun-ichi
    Nanto, Shinsuke
    Uematsu, Masaaki
    Morozumi, Takakazu
    Onishi, Toshinari
    Iida, Osamu
    Sera, Fusako
    Minamiguchi, Hitoshi
    Akahori, Hirokuni
    Yano, Masamichi
    Yasui, Hiroki
    Nagata, Seiki
    CIRCULATION, 2006, 114 (18) : 453 - 453
  • [2] Incomplete neointimal coverage two years after sirolimus-eluting stent implantation: A serial angioscopic follow-up study
    Awata, Masaki
    Kotani, Jun-ichi
    Uematsu, Masaaki
    Morozumi, Takakazu
    Watanabe, Tetsuya
    Onishi, Toshinari
    Iida, Osamu
    Sera, Fusako
    Alkahon, Hirokuni
    Yano, Masamichi
    Tanaka, Nobuaki
    Yasui, Haruyo
    Ikeoka, Kuniyasu
    Okamoto, Shin
    Nanto, Shinsuke
    Nagata, Saild
    CIRCULATION, 2007, 116 (16) : 617 - 617
  • [3] Incomplete neointimal coverage of sirolimus-eluting stents - Angioscopic findings
    Kotani, Jun-ichi
    Awata, Masaki
    Nanto, Shinsuke
    Uematsu, Masaaki
    Oshima, Fusako
    Minamiguchi, Hitoshi
    Mintz, Gary S.
    Nagata, Seiki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2006, 47 (10) : 2108 - 2111
  • [4] Incomplete Neointimal Coverage Persists Beyond 4 Years After Sirolimus-Eluting Stent Implantation: Angioscopic Follow-up Study in Patients
    Awata, Masaki
    Nanto, Shinsuke
    Uematsu, Masaaki
    Morozumi, Takakazu
    Watanabe, Tetsuya
    Fujita, Masashi
    Onishi, Toshinari
    Iida, Osamu
    Sera, Fusako
    Okamoto, Shin
    Yasui, Haruyo
    Ikeoka, Kuniyasu
    Tanaka, Nobuaki
    Ishihara, Takayuki
    Dohi, Tomoharu
    Mishima, Tuyoshi
    Nagata, Seiki
    CIRCULATION, 2009, 120 (18) : S979 - S980
  • [5] Difference of Heterogeneity of Neointimal Coverage between Sirolimus-Eluting Stent and Paclitaxel-Eluting Stent: An Angioscopic Study
    Hara, Masahiko
    Nishino, Masami
    Yoshimura, Takahiro
    Lee, Yasuharu
    Nakamura, Daisuke
    Nakatani, Shinpei
    Hashimoto, Akihito
    Yamagami, Kiyoshi
    Taniike, Masayuki
    Kato, Hiroyasu
    Egami, Yasuyuki
    Shutta, Ryu
    Yamaguchi, Hitoshi
    Tanaka, Kenjiro
    Tanouchi, Jun
    Yamada, Yoshio
    CIRCULATION, 2008, 118 (18) : S735 - S735
  • [6] Angioscopic findings of sirolimus-eluting stent for acute myocardial infarction: An intermediate-term follow-up study
    Dai, Kazuolki
    Ishihara, Masaharu
    Inoue, Ichiro
    Kawagoe, Takul
    Shimatani, Yuji
    Kurisu, Satoshi
    Nakama, Yasuharu
    Maruhashi, Tatsuya
    Kagawa, Eisuke
    Aokage, Toshiyuki
    Ikenaga, Hiroki
    CIRCULATION, 2007, 116 (16) : 710 - 710
  • [7] Serial angioscopic evidence of incomplete neointimal coverage after sirolimus-eluting stent implantation
    Awata, Masaki
    Kotani, Jun-ichi
    Uematsu, Masaaki
    Morozumi, Takakazu
    Watanabe, Tetsuya
    Onishi, Toshinari
    Iida, Osamu
    Sera, Fusako
    Nanto, Shinsuke
    Hori, Masatsugu
    Nagata, Seiki
    CIRCULATION, 2007, 116 (08) : 910 - 916
  • [8] Time course of neointimal coverage following sirolimus-eluting stent implantation: Up to 2 years serial angioscopic study
    Awata, Masaki
    Kotani, Jun-Ichi
    Uematsu, Mosaaki
    Morozumi, Tokakazu
    Watanabe, Tetsuya
    Onishi, Toshinari
    Iida, Osamu
    Sera, Fusako
    Minamiguchi, Hitoshi
    Akahori, Hirokuni
    Yano, Masamichi
    Nanto, Shinsuke
    Nagata, Seiki
    AMERICAN JOURNAL OF CARDIOLOGY, 2007, 100 (8A): : 33L - 33L
  • [9] Angioscopic comparison of neointimal coverage between zotarolimus- and sirolimus-eluting stents
    Awata, Masaki
    Nanto, Shinsuke
    Uematsu, Masaaki
    Morozumi, Takakazu
    Watanabe, Tetsuya
    Onishi, Toshinari
    Iida, Osamu
    Sera, Fusako
    Kotani, Jun-ichi
    Hori, Masatsugu
    Nagata, Seiki
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2008, 52 (09) : 789 - 790
  • [10] Evaluation of long-term follow-up with neointimal coverage and stent apposition after sirolimus-eluting stent implantation by optical coherence tomography
    Li, Shan
    Gai, Luyue
    Yang, Tingshu
    Zhang, Li
    Xu, Xiuli
    Bai, Qicai
    Xu, Hang
    Wang, Yutang
    CATHETERIZATION AND CARDIOVASCULAR INTERVENTIONS, 2013, 81 (05) : 768 - 775