Comparison of conventional and hybrid modulus press-fit proximal femoral prostheses

被引:0
|
作者
Simoes, JAO
Taylor, M
机构
来源
SIMULATION MODELLING IN BIOENGINEERING | 1996年
关键词
hybrid modulus prosthesis; cancellous bone stress; strain energy;
D O I
暂无
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
The aim of the this study was to compare the load transfer mechanisms of a standard press-fit proximal femoral prosthesis fabricated from three conventional implant materials, cobalt-chrome, titanium and an 'isoelastic' material with that produced by a hybrid modulus prosthesis using the finite element method. In particular, both the periosteal and the endosteal bone stresses were examined. Comparison of the results from the three conventional implant materials were similar to those reported in the literature, with the isoelastic prosthesis producing the least stress shielding of the proximal medial femur and the stiffer implant materials producing low proximal medial interface pressures and cancellous bone stress distributions. The hybrid prosthesis combined these features to produce, overall, the most favourable periosteal and endosteal stress distributions. However, all of the prostheses produced stresses which approach or exceeded the fatigue strength of the supporting cancellous bone suggesting that all would have high migration rates and correspondingly high rates of late aseptic loosening.
引用
收藏
页码:127 / 139
页数:13
相关论文
共 50 条
  • [1] STRAINS AND MICROMOTIONS OF PRESS-FIT FEMORAL STEM PROSTHESES
    WALKER, PS
    SCHNEEWEIS, D
    MURPHY, S
    NELSON, P
    JOURNAL OF BIOMECHANICS, 1987, 20 (07) : 693 - 702
  • [2] A COMPARISON OF CORTICAL STRAIN AFTER CEMENTED AND PRESS-FIT PROXIMAL AND DISTAL FEMORAL REPLACEMENT
    HUA, J
    WALKER, PS
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1992, 10 (05) : 739 - 744
  • [3] A HISTOLOGIC COMPARISON OF ASEPTIC LOOSENING OF CEMENTED, PRESS-FIT, AND BIOLOGIC INGROWTH PROSTHESES
    LENNOX, DW
    SCHOFIELD, BH
    MCDONALD, DF
    RILEY, LH
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1987, (225) : 171 - 191
  • [4] Effect of proximal femoral bone support on the fixation of a press-fit noncemented total hip replacement femoral component
    Sangiorgio, Sophia N.
    Ebramzadeh, Edward
    Borkowski, Sean L.
    Oakes, Daniel A.
    Reid, Jeremy J.
    Bengs, Benjamin C.
    JOURNAL OF APPLIED BIOMATERIALS & FUNCTIONAL MATERIALS, 2013, 11 (01): : 26 - 34
  • [5] Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses
    Bühler, D.W.
    Oxland, T.R.
    Nolte, L.-P.
    Medical Engineering and Physics, 1997, 19 (02): : 187 - 199
  • [6] Design and evaluation of a device for measuring three-dimensional micromotions of press-fit femoral stem prostheses
    Buhler, DW
    Oxland, TR
    Nolte, LP
    MEDICAL ENGINEERING & PHYSICS, 1997, 19 (02) : 187 - 199
  • [7] CEMENTLESS TITANIUM PRESS-FIT FEMORAL PROSTHESIS IN THE DOG
    ANDERSON, GI
    SUMNERSMITH, G
    COCKSHUTT, J
    VETERINARY SURGERY, 1988, 17 (01) : 27 - 27
  • [8] The use of hydroxyapatite on press-fit tapered femoral stems
    Maheshwari, Aditya V.
    Ranawat, Amar S.
    Ranawat, Chitranjan S.
    ORTHOPEDICS, 2008, 31 (09) : 882 - 884
  • [9] Cemented and Press-fit Femoral Stems for the Management of Oncologic Femoral Tumors
    Su, Marie W.
    Groot, Oliver Q.
    Werenski, Joseph O.
    Sodhi, Alisha
    Merchan, Nelson
    Anderson, Megan E.
    Heincelman, Carrie
    Chang, Connie Y.
    Lozano-Calderon, Santiago A.
    JOURNAL OF THE AMERICAN ACADEMY OF ORTHOPAEDIC SURGEONS, 2024, 32 (14) : e695 - e705
  • [10] Press-Fit Hemihamate Arthroplasty for the Proximal Interphalangeal Joint
    Takeya, Hiroaki
    Iwamoto, Takuji
    Kimura, Hiroo
    Suzuki, Taku
    Matsumura, Noboru
    Hosozawa, Tetsuji
    Iwabu, Shohei
    JOURNAL OF WRIST SURGERY, 2023, 12 (04) : 371 - 376