EUS-guided fine needle biopsy sampling using a novel fork-tip needle: a case-control study

被引:104
|
作者
Kandel, Pujan [1 ]
Tranesh, Ghassan [2 ]
Nassar, Aziza [2 ]
Bingham, Russell [1 ]
Raimondo, Massimo [1 ]
Woodward, Timothy A. [1 ]
Gomez, Victoria [1 ]
Wallace, Michael B. [1 ]
机构
[1] Mayo Clin, Dept Gastroenterol & Hepatol, Jacksonville, FL 32224 USA
[2] Mayo Clin, Dept Pathol, Jacksonville, FL 32224 USA
关键词
SOLID PANCREATIC MASSES; TRUCUT NEEDLE; ENDOSCOPIC ULTRASONOGRAPHY; TISSUE ACQUISITION; ASPIRATION; FNA; DIAGNOSIS; LESIONS; LYMPHADENOPATHY; METAANALYSIS;
D O I
10.1016/j.gie.2016.03.1405
中图分类号
R57 [消化系及腹部疾病];
学科分类号
摘要
Background and Aims: EUS-guided fine needle biopsy (FNB) sampling and FNA are important methods for obtaining core tissues and cytologic aspirates. To improve the specimen quality for pathologic evaluation, a novel EUS-FNB Shark Core (SC) needle has been designed to acquire core tissue during EUS procedures. We compared the histology yield of EUS-FNB sampling using the SC needle (EUS-FNB-SC) to EUS-FNA in patients who had solid pancreatic and nonpancreatic lesions. Methods: This was a retrospective case-control study design. Between July 2012 and July 2015 all patients who had EUS-FNB-SC and EUS-FNA were reviewed through a hospital EUS database. Consecutive samples from EUS-FNB-SCs were matched in a 1:3 ratio by lesion site (eg, pancreatic head) and needle gauge (ie, 19 gauge, 22 gauge, 25 gauge) to recent random samples of EUS-FNA. The procedures were performed with rapid onsite evaluation. For study purposes specimen slides were evaluated by 2 cytopathologists for histologic yield using a standard scoring system (0 = no material, 1-2 = cytologic, 3-5 = histologic). The main objectives were to assess the histologic yield of the samples and compare the median number of passes required to obtain core tissue by using EUS-FNB-SC and EUS-FNA needles. Results: Of the 156 patients included in study, 25% patients (n = 39) were in the EUS-FNB-SC group and 75% (n = 117) in the EUS-FNA group. According to standard scoring criteria for histology, the median histology score for EUS-FNA was 2 (sufficient for cytology but not histology) and for EUS-FNB-SC was 4 (sufficient for adequate histology). Ninety-five percent of the specimens obtained from the EUS-FNB-SC group were of sufficient size for histologic screening, compared with 59% from the EUS-FNA group (P = .01). The median number of passes required to achieve a sample was significantly lower in the EUS-FNB-SC group compared with the EUS-FNA group (2 passes vs 4 passes, P = .001). There was significant difference in the median number of passes to all lesion sites and needle gauges. Conclusions: The histology yield was significantly higher using the EUS-FNB-SC needle compared with the EUS-FNA needle. Additionally, fewer passes were required to obtain histology cores when using EUS-FNB-SC.
引用
收藏
页码:1034 / 1039
页数:6
相关论文
共 50 条
  • [1] Endoscopic Ultrasound Guided Fine Needle Biopsy (EUS-FNB-SC) Using a Novel Fork-Tip Needle: A Case Control Study
    Kandel, Pujan
    Tranesh, Ghassan
    Nassar, Aziza
    Raimondo, Massimo
    Woodward, Timothy A.
    Gomez, Victoria
    Bingham, Russell
    Wallace, Michael B.
    GASTROINTESTINAL ENDOSCOPY, 2016, 83 (05) : AB354 - AB355
  • [2] Randomized controlled trial comparing the Franseen needle with the Fork-tip needle for EUS-guided fine-needle biopsy
    Ashat, Munish
    Klair, Jagpal S.
    Rooney, Sydney L.
    Vishal, Sagar J.
    Jensen, Chris
    Sahar, Nadav
    Murali, Arvind R.
    El-Abiad, Rami
    Gerke, Henning
    GASTROINTESTINAL ENDOSCOPY, 2021, 93 (01) : 140 - +
  • [3] Randomized trial comparing the Franseen and Fork-tip needles for EUS-guided fine-needle biopsy sampling of solid pancreatic mass lesions
    Bang, Ji Young
    Hebert-Magee, Shantel
    Navaneethan, Udayakumar
    Hasan, Muhammad K.
    Hawes, Robert
    Varadarajulu, Shyam
    GASTROINTESTINAL ENDOSCOPY, 2018, 87 (06) : 1432 - 1438
  • [4] Performance of a Fork Tipped Needle versus Reverse Bevel Needle in EUS-Guided Fine Needle Biopsy
    Jeffrey, Hubers
    Nelsen, Eric M.
    Holobyn, Thomas J.
    Gopal, Deepak V.
    Pfau, Patrick R.
    Benson, Mark E.
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2017, 112 : S461 - S462
  • [5] EUS-guided fine needle biopsy sampling in autoimmune pancreatitis: Is needle tip design more important than needle size?
    Hedenstrom, Per
    Lindkvist, Bjorn
    ENDOSCOPY INTERNATIONAL OPEN, 2020, 08 (12) : E1862 - E1864
  • [6] EUS-guided core biopsies of pancreatic solid masses using a new fork-tip needle: A multicenter prospective study
    Di Leo, Milena
    Crino, Stefano Francesco
    Bernardoni, Laura
    Rahal, Daoud
    Auriemma, Francesco
    Correale, Loredana
    Donato, Giulio
    Massidda, Marco
    Anderloni, Andrea
    Manfrin, Erminia
    Armellini, Elia
    Poliani, Laura
    Fugazza, Alessandro
    Semeraro, Rossella
    Occhipinti, Pietro
    Repici, Alessandro
    Carrara, Silvia
    DIGESTIVE AND LIVER DISEASE, 2019, 51 (09) : 1275 - 1280
  • [7] EUS TISSUE SAMPLING WITH FORK-TIP BIOPSY NEEDLE IN THE DIAGNOSIS OF TYPE 1 AUTOIMMUNE PANCREATITIS
    Oppong, Kofi
    Maheshwari, Pardeep
    Haugk, Beate
    Leeds, John
    Huggettt, Matthew
    Paranandi, Bharat
    Darne, Antony
    Nayar, Manu
    GUT, 2019, 68 : A5 - A5
  • [8] Randomized trial comparing fork-tip and side-fenestrated needles for EUS-guided fine-needle biopsy of solid pancreatic lesions
    Crino, Stefano Francesco
    Le Grazie, Marco
    Manfrin, Erminia
    Bellocchi, Maria Cristina Conti
    Bernardoni, Laura
    Granato, Anna
    Locatelli, Francesca
    Parisi, Alice
    Di Stefano, Serena
    Frulloni, Luca
    Larghi, Alberto
    Gabbrielli, Armando
    GASTROINTESTINAL ENDOSCOPY, 2020, 92 (03) : 648 - +
  • [9] Comparison of Franseen and fork-tip needles for EUS-guided fine-needle biopsy of solid mass lesions: A systematic review and meta-analysis
    Mohan, Babu P.
    Shakhatreh, Mohammed
    Garg, Rajat
    Asokkumar, Ravishankar
    Jayaraj, Mahendran
    Ponnada, Suresh
    Navaneethan, Udayakumar
    Adler, Douglas G.
    ENDOSCOPIC ULTRASOUND, 2019, 8 (06) : 382 - +
  • [10] Autoimmune Pancreatitis Diagnosed by a Core Biopsy Obtained from a Novel Fork-Tip EUS Needle
    Kerdsirichairat, Tossapol
    Saini, Sameer D.
    Gupta, Samardeep
    Prabhu, Anoop
    AMERICAN JOURNAL OF GASTROENTEROLOGY, 2016, 111 : S513 - S513