Modeling the failures of power-aware data centers by leveraging heat recirculation

被引:0
|
作者
Feng, Hao [1 ]
Deng, Yuhui [1 ,2 ]
Yu, Liang [1 ]
机构
[1] Jinan Univ, Dept Comp Sci, 601 West Huangpu Ave, Guangzhou 510632, Peoples R China
[2] Chinese Acad Sci, Inst Comp Technol, Key Lab Comp Architecture, Beijing, Peoples R China
来源
关键词
data center; energy efficiency; heat recirculation; node failure; task schedule;
D O I
10.1002/cpe.5244
中图分类号
TP31 [计算机软件];
学科分类号
081202 ; 0835 ;
摘要
With the explosive growth of data, hundreds of thousands of servers may be contained in a single data center. Hence, node failures are unavoidable and generally negatively effects the performance of the whole data center. Additionally, data centers with a large number of nodes will cause plenty of energy consumption. Many existing task scheduling techniques can effectively reduce the power consumption in data centers by considering heat recirculation. However, the traditional techniques do not take the situation of node failures into account. This paper proposes an airflow-based failure model for data centers by leveraging heat recirculation. In this model, the spatial distribution and time distribution of failures are considered. Furthermore, a genetic algorithm (GA) and a simulated annealing algorithm (SA) are implemented to evaluate the proposed failure model. Because the positions of node failures have a significant impact on the heat recirculation and the energy consumption of data centers, failures with different positions are analyzed and evaluated. The experimental results demonstrate that the energy consumption of data centers can be significantly reduced by using the GA and SA algorithms for task scheduling based on the proposed failure model.
引用
收藏
页数:15
相关论文
共 50 条
  • [1] Power-Aware Management in Cloud Data Centers
    Milenkovic, Milan
    Castro-Leon, Enrique
    Blakley, James R.
    [J]. CLOUD COMPUTING, PROCEEDINGS, 2009, 5931 : 668 - 673
  • [2] Power-aware workload allocation for green data centers
    Chaddad, Louma Ahmad
    Chehab, Ali
    Elhajj, Imad
    Kayssi, Ayman
    [J]. MANAGEMENT OF ENVIRONMENTAL QUALITY, 2018, 29 (04) : 678 - 703
  • [3] Power-Aware Design of the Optical Interconnect for Future Data Centers
    Naas, Nabil
    Mouftah, Hussein
    [J]. 2016 IEEE SYMPOSIUM ON COMPUTERS AND COMMUNICATION (ISCC), 2016, : 675 - 682
  • [4] Enabling Autonomic Power-Aware Management of Instrumented Data Centers
    Jiang, Nanyan
    Parashar, Manish
    [J]. 2009 IEEE INTERNATIONAL SYMPOSIUM ON PARALLEL & DISTRIBUTED PROCESSING, VOLS 1-5, 2009, : 1952 - 1959
  • [5] A Heat-Recirculation-Aware Data Placement Strategy towards Data Centers
    Zhong, Zijie
    Deng, Yuhui
    Li, Jie
    [J]. 2022 IEEE 28TH INTERNATIONAL CONFERENCE ON PARALLEL AND DISTRIBUTED SYSTEMS, ICPADS, 2022, : 578 - 585
  • [6] A Heat-Recirculation-Aware VM Placement Strategy for Data Centers
    Feng, Hao
    Deng, Yuhui
    Zhou, Yi
    [J]. PROCEEDINGS OF THE 2020 DESIGN, AUTOMATION & TEST IN EUROPE CONFERENCE & EXHIBITION (DATE 2020), 2020, : 626 - 629
  • [7] Towards Heat-Recirculation-Aware Virtual Machine Placement in Data Centers
    Feng, Hao
    Deng, Yuhui
    Zhou, Yi
    Min, Geyong
    [J]. IEEE TRANSACTIONS ON NETWORK AND SERVICE MANAGEMENT, 2022, 19 (01): : 256 - 270
  • [8] Modeling and analysis of power-aware systems
    Sokolsky, O
    Philippou, A
    Lee, I
    Christou, K
    [J]. TOOLS AND ALGORITHMS FOR THE CONSTRUCTION AND ANALYSIS OF SYSTEMS, PROCEEDINGS, 2003, 2619 : 409 - 424
  • [9] Power-Aware Partitioning of Data Converters
    Bonanno, Alberto
    Bocca, Alberto
    Macii, Alberto
    Macii, Enrico
    [J]. PROCEEDINGS OF THE 2010 18TH IEEE/IFIP INTERNATIONAL CONFERENCE ON VLSI AND SYSTEM-ON-CHIP, 2010, : 358 - 363
  • [10] Thermal-Aware Task Scheduling for Data centers through Minimizing Heat Recirculation
    Tang, Qinghui
    Gupta, Sandeep K. S.
    Varsamopoulos, Georgios
    [J]. 2007 IEEE INTERNATIONAL CONFERENCE ON CLUSTER COMPUTING, 2007, : 129 - 138