Microtensile bond strength of resin composite bonded to caries-affected dentin with three adhesives

被引:30
|
作者
Omar, H.
El-Badrawy, W.
El-Mowafy, O.
Atta, O.
Saleem, B.
机构
[1] Suez Canal Univ, Fac Dent, Dept Fixed Prosthodont, Ismailia, Egypt
[2] Univ Toronto, Fac Dent, Dept Clin Sci, Toronto, ON, Canada
关键词
D O I
10.2341/06-2
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
This study evaluated the ability of two self-etching adhesives (a two-step and a one-step) and a conventional 3-step adhesive to bond composite to both intact and caries-affected dentin with and without thermocycling. Thirty extracted human teeth with occlusal caries were randomly assigned to three groups according to the adhesive used: Scotchbond Multi-purpose (3M) (SBMP), ClearfilSE Bond (Kuraray) (SE) and Xeno IV (Dentsply) (XEIV). The occlusal surfaces of the teeth were sectioned to expose dentin. The adhesives were applied according to manufacturers' instructions, and a composite material (Herculite XRV, Kerr) was applied and cured in increments to form a core 3 mm high. The teeth were stored in distilled water for 24 hours, then sectioned using a micro-slicing machine to obtain sections 1 nun thick. The sections were further cut to obtain rods 6 nun long and 1 x 1 mm in thickness, with dentin/composite interface located at the center. The specimens were examined microscopically to separate the caries-affected (AD) and sound dentin (SD) into two groups. Half the specimens from each group were subjected to 3,000 thermocycles (5 degrees C to 55 degrees C) prior to testing. All the specimens were then subjected to microtensile bond strength (mu TBS) testing in a special apparatus. Mean mu TBS was determined for each group, and data were statistically analyzed with ANOVA and Tukey's tests. Mean mu TBS and standard deviation values in MPa were: SBMP-SD = 22.19 (4.6), SBMP-SD-thermocycled = 15.7 (5.55), SBMP-AD = 18.6 (2.89), SBMPAD-thermocycled = 16.62 (6.23), SE-SD = 24.25 (5.7), SE-SD-thermocycled = 22.3 (6.7), SE-AD = 20.7 (5.55), SE-AD-thermocycled = 20.23 (6.1), XEIV-SD = 21.43 (7.6), XEIV-SD-thermocycled = 18.3 (7.11), XEIV-AD = 15.45 (6.62), XEIV-AD-thermocycled = 14.8 (3.89). ANOVA revealed a significant difference among the groups (p<0001). The two-step self-etch adhesive resulted in highest mean mu TBS values under all test conditions. However, these mean values were significantly higher than the mean values obtained with the other two adhesives under some, but not all test conditions.
引用
收藏
页码:24 / 30
页数:7
相关论文
共 50 条
  • [1] MICROTENSILE BOND STRENGTH OF RESIN CEMENTS TO CARIES-AFFECTED DENTIN
    Suzuki, Thais Y. U.
    Godas, Andre G. L.
    Guedes, Ana P. A.
    Catelan, Anderson
    Pavan, Sabrina
    Briso, Andre L. F.
    dos Santos, Paulo H.
    JOURNAL OF PROSTHETIC DENTISTRY, 2013, 110 (01): : 47 - 55
  • [2] Microtensile Bond Strength of Three Simplified Adhesive Systems to Caries-affected Dentin
    Scholtanusa, J. D.
    Purwanta, Kenny
    Dogan, Nilgun
    Kleverlaan, Cees J.
    Feilzer, Albert J.
    JOURNAL OF ADHESIVE DENTISTRY, 2010, 12 (04): : 273 - 278
  • [3] Evaluation of microtensile bond strength of self-etching adhesives on normal and caries-affected dentin
    Shibata, Shizuma
    Cardoso Vieira, Luiz Clovis
    Baratieri, Luiz Narciso
    Fu, Jiale
    Hoshika, Shuhei
    Matsuda, Yasuhiro
    Sano, Hidehiko
    DENTAL MATERIALS JOURNAL, 2016, 35 (02) : 166 - 173
  • [4] Bond strength of five current adhesives to caries-affected dentin
    Sengün, A
    Ünlü, N
    Özer, F
    Öztürk, B
    JOURNAL OF ORAL REHABILITATION, 2002, 29 (08) : 777 - 781
  • [5] Microtensile bond strength of different bonding systems to caries-affected dentin.
    Camejo, D
    Ceballos, L
    Osorio, R
    Toledano, M
    Carvalho, RM
    Pashley, DH
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 575 - 575
  • [6] Effect of Method of Removing Caries-Affected Dentin on the Bond Strength of Composite Resin to Root Canal Dentin
    Otake, Shiho
    Oishi, Shinya
    Ozaki, Taisuke
    Ikeda, Masaomi
    Komada, Wataru
    HEALTHCARE, 2022, 10 (11)
  • [7] Tensile bond strength and SEM evaluation of caries-affected dentin using dentin adhesives
    Nakajima, M
    Sano, H
    Burrow, MF
    Tagami, J
    Yoshiyama, M
    Ebisu, S
    Ciucchi, B
    Russell, CM
    Pashley, DH
    JOURNAL OF DENTAL RESEARCH, 1995, 74 (10) : 1679 - 1688
  • [8] Elemental distributions and microtensile bond strength of the adhesive interface to normal and caries-affected dentin
    Nakajima, M
    Kitasako, Y
    Okuda, M
    Foxton, RM
    Tagami, J
    JOURNAL OF BIOMEDICAL MATERIALS RESEARCH PART B-APPLIED BIOMATERIALS, 2005, 72B (02) : 268 - 275
  • [9] Effect of Different Application Techniques of All-in-One Adhesives on Microtensile Bond Strength to Sound and Caries-Affected Dentin
    Tekce, Neslihan
    Demirci, Mustafa
    Tuncer, Safa
    Uysal, Omer
    JOURNAL OF ADHESION, 2015, 91 (04): : 245 - 261
  • [10] Effect of Er,Cr:YSGG Laser on the Microtensile Bond Strength of Two Different Adhesives to the Sound and Caries-affected Dentin
    Ergucu, Z.
    Celik, E. U.
    Unlu, N.
    Turkun, M.
    Ozer, F.
    OPERATIVE DENTISTRY, 2009, 34 (04) : 460 - 466