Using minimum deviation of a secondary rainbow and its application to water analysis in a high-precision, refractive-index comparator for liquids

被引:21
|
作者
Hattori, H
Yamanaka, H
Kurniawan, H
Yokoi, S
Kagawa, K
机构
[1] UNIV INDONESIA,SPECT & LASER APPLICAT LAB,JAKARTA 10430,INDONESIA
[2] OTEMON GAKUIN HIGH SCH,OSAKA 540,JAPAN
来源
APPLIED OPTICS | 1997年 / 36卷 / 22期
关键词
D O I
10.1364/AO.36.005552
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
A new method for measuring the refractive-index difference of a liquid has been developed, The liquid to be measured is contained in a 60-mm-diameter, cylindrical glass cell, and a He-hie laser light is passed into the cell so that the laser light incidence fulfills the condition of minimum deviation. In this condition, the beam emerging from the cell has a fine interference Fringe. The position of the interference fringe is read out as st marker to measure the deflection of the laser light. Directly reading the peak shift of the interference fringe makes it easy to obtain the refractive index difference of the liquid with a fairly high precision of at least 6 x 10(-6). Further high precision is potentially expected to be realized by use of an improved data analysis treatment of the overall interference fringe pattern. (C) 1997 Optical Society of America.
引用
收藏
页码:5552 / 5556
页数:5
相关论文
共 35 条
  • [1] A SIMPLE, ACCURATE ALTERNATIVE TO THE MINIMUM DEVIATION METHOD OF DETERMINING THE REFRACTIVE-INDEX OF LIQUIDS
    CHANDRA, BP
    BHAIYA, SC
    [J]. AMERICAN JOURNAL OF PHYSICS, 1983, 51 (02) : 160 - 161
  • [2] HIGH-PRECISION REFRACTIVE-INDEX DISTRIBUTION MEASUREMENT OF OPTICAL WAVE-GUIDES
    TIAN, XK
    LAI, G
    YATAGAI, T
    SEKI, M
    [J]. OPTICS COMMUNICATIONS, 1988, 69 (01) : 11 - 14
  • [3] HIGH-PRECISION MEASUREMENT FOR REFRACTIVE-INDEX DISTRIBUTION AND DISPERSION USING AN IMPROVED SCANNING TOTAL REFLECTION METHOD
    HASHIMOTO, T
    MATSUZAKI, H
    TSUCHIDA, H
    YAMAMOTO, K
    [J]. JAPANESE JOURNAL OF APPLIED PHYSICS PART 1-REGULAR PAPERS SHORT NOTES & REVIEW PAPERS, 1992, 31 (5B): : 1602 - 1605
  • [4] Precision test technology of liquid refractive index using the method of minimum deviation angle
    Sun Yi-shu
    Chen Yi
    Han Bing
    Yuan Li
    [J]. CHINESE OPTICS, 2019, 12 (04): : 826 - 832
  • [5] Zygo interferometer for measuring refractive index of liquids and its application for heavy water analysis
    Shukla, RP
    Udupa, DV
    [J]. OPTICS AND LASER TECHNOLOGY, 2000, 32 (05): : 355 - 360
  • [6] HIGH-PRECISION REFRACTIVE-INDEX MEASUREMENTS REVEALING ORDER PARAMETER FLUCTUATIONS IN KMNF3 AND NIO
    SCHAFER, FJ
    KLEEMANN, W
    [J]. JOURNAL OF APPLIED PHYSICS, 1985, 57 (07) : 2606 - 2612
  • [7] High-precision frequency attenuation analysis and its application
    Xiao-Jun Xiong
    Xi-Lei He
    Yong Pu
    Zhen-Hua He
    Kai Lin
    [J]. Applied Geophysics, 2011, 8 : 337 - 343
  • [8] High-precision frequency attenuation analysis and its application
    Xiong Xiao-Jun
    He Xi-Lei
    Pu Yong
    He Zhen-Hua
    Lin Kai
    [J]. APPLIED GEOPHYSICS, 2011, 8 (04) : 337 - 343
  • [9] Temperature insensitive high-precision refractive-index sensor using two concatenated dual-resonance long-period gratings
    Tripathi, Saurabh Mani
    Bock, Wojtek J.
    Kumar, Arun
    Mikulic, Predrag
    [J]. OPTICS LETTERS, 2013, 38 (10) : 1666 - 1668
  • [10] Optimization design and test of a high-precision measuring deviceof liquid refractive index based on the method ofminimum deviation angle
    Fu Xing-li
    Feng Jie
    Fan Xiao-hui
    Pan Meng-yun
    Wei Qiu-ye
    [J]. CHINESE OPTICS, 2022, 15 (04) : 789 - 796