Acoustic radiation force impulse under clinical conditions with single infusion of ultrasound contrast agent evoking arrhythmias in rabbit heart

被引:4
|
作者
Rifu, Kazuma [1 ]
Sasanuma, Hideki [1 ]
Takayama, Noriya [2 ]
Nitta, Naotaka [3 ]
Ogata, Yukiyo [4 ]
Akiyama, Iwaki [5 ]
Taniguchi, Nobuyuki [2 ]
机构
[1] Jichi Med Univ, Dept Surg, Div Gastroenterol Gen & Transplant Surg, 3311-1 Yakushiji, Shimotsuke, Tochigi 3290498, Japan
[2] Jichi Med Univ, Dept Clin Lab Med, 3311-1 Yakushiji, Shimotsuke, Tochigi 3290498, Japan
[3] Natl Inst Adv Ind Sci & Technol, Hlth & Med Res Inst, 1-2-1 Namiki, Tsukuba, Ibaraki 3058564, Japan
[4] Jichi Med Univ, Dept Cardiol, 3311-1 Yakushiji, Shimotsuke, Tochigi 3290498, Japan
[5] Doshisha Univ, Med Ultrasound Res Ctr, 1-3 Tatara Miyakodani, Kyoto 6100321, Japan
基金
日本学术振兴会;
关键词
Acoustic radiation force impulse; Ultrasound contrast agent; Heart; Elastography; Arrhythmia;
D O I
10.1007/s10396-021-01085-3
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose We previously reported that acoustic radiation force impulse (ARFI) with concomitant administration of perfluorobutane as an ultrasound contrast agent (UCA)-induced arrhythmias at a mechanical index (MI) of 1.8 or 4.0 in a rabbit model. The present study identified the location of arrhythmias with a MI < 1.8 using a new system that can transmit ARFI with B-mode imaging. Methods Under general anesthesia, six male Japanese white rabbits were placed in a supine position. Using this system, we targeted ARFI to the exact site of the heart. ARFI exposure with MI 0.9-1.2 was performed to the right or left ventricle of the heart 2 min after UCA injection. Results ARFI with a MI lower than previously reported to rabbit heart evoked extrasystolic waves with single UCA infusion. Arrhythmias were not observed using ARFI without UCA. Extrasystolic waves were observed significantly more frequently in the right ventricle group than in the left ventricle group, with arrhythmias showing reversed shapes. No fatal arrhythmias were observed. Conclusion ARFI applied to simulate clinical conditions in rabbit heart evoked extrasystolic waves with single UCA infusion. The right ventricle group was significantly more sensitive to ARFI exposure, resulting in arrhythmias, than the left ventricle group. The shapes of PVCs that occurred in the right ventricle group and the left ventricle group were reversed. Ultrasound practitioners who use ARFI should be aware of this adverse reaction, even if the MI is below the previously determined value of 1.9.
引用
收藏
页码:137 / 144
页数:8
相关论文
共 26 条
  • [1] Acoustic radiation force impulse under clinical conditions with single infusion of ultrasound contrast agent evoking arrhythmias in rabbit heart
    Kazuma Rifu
    Hideki Sasanuma
    Noriya Takayama
    Naotaka Nitta
    Yukiyo Ogata
    Iwaki Akiyama
    Nobuyuki Taniguchi
    Journal of Medical Ultrasonics, 2021, 48 : 137 - 144
  • [2] The arrhythmogenic effect of ultrasonic exposure with acoustic radiation force (ARF) impulse on the rabbit heart with ultrasound contrast agent perfluorobutane
    Yasunao Ishiguro
    Hideki Sasanuma
    Naotaka Nitta
    Nobuyuki Taniguchi
    Yukiyo Ogata
    Yoshikazu Yasuda
    Iwaki Akiyama
    Journal of Medical Ultrasonics, 2015, 42 : 47 - 50
  • [3] The arrhythmogenic effect of ultrasonic exposure with acoustic radiation force (ARF) impulse on the rabbit heart with ultrasound contrast agent perfluorobutane
    Ishiguro, Yasunao
    Sasanuma, Hideki
    Nitta, Naotaka
    Taniguchi, Nobuyuki
    Ogata, Yukiyo
    Yasuda, Yoshikazu
    Akiyama, Iwaki
    JOURNAL OF MEDICAL ULTRASONICS, 2015, 42 (01) : 47 - 50
  • [4] Ultrasound exposure (mechanical index 1.8) with acoustic radiation force impulse evokes extrasystolic waves in rabbit heart under concomitant administration of an ultrasound contrast agent
    Yasunao Ishiguro
    Naotaka Nitta
    Nobuyuki Taniguchi
    Kazuki Akai
    Noriya Takakayama
    Hideki Sasanuma
    Yukiyo Ogata
    Yoshikazu Yasuda
    Iwaki Akiyama
    Journal of Medical Ultrasonics, 2016, 43 : 3 - 7
  • [5] Erratum to: Ultrasound exposure (mechanical index 1.8) with acoustic radiation force impulse evokes extrasystolic waves in rabbit heart under concomitant administration of an ultrasound contrast agent
    Yasunao Ishiguro
    Naotaka Nitta
    Nobuyuki Taniguchi
    Kazuki Akai
    Noriya Takayama
    Hideki Sasanuma
    Yukiyo Ogata
    Yoshikazu Yasuda
    Iwaki Akiyama
    Journal of Medical Ultrasonics, 2016, 43 : 9 - 9
  • [6] Ultrasound exposure (mechanical index 1.8) with acoustic radiation force impulse evokes extrasystolic waves in rabbit heart under concomitant administration of an ultrasound contrast agent (vol 43, pg 3, 2016)
    Ishiguro, Yasunao
    Nitta, Naotaka
    Taniguchi, Nobuyuki
    Akai, Kazuki
    Takayama, Noriya
    Sasanuma, Hideki
    Ogata, Yukiyo
    Yasuda, Yoshikazu
    Akiyama, Iwaki
    JOURNAL OF MEDICAL ULTRASONICS, 2016, 43 (01) : 9 - 9
  • [7] Acoustic radiation force impulse (push pulse)-induced lung hemorrhage: investigating the effect of ultrasound contrast agent in rabbits
    Takayama, Noriya
    Sasanuma, Hideki
    Rifu, Kazuma
    Nitta, Naotaka
    Akiyama, Iwaki
    Taniguchi, Nobuyuki
    JOURNAL OF MEDICAL ULTRASONICS, 2025, 52 (01) : 17 - 25
  • [8] Acoustic radiation force enhances ultrasound contrast agent retention to P-selectin in vivo
    Rychak, JJ
    Ley, K
    Klibanov, A
    Hossack, J
    2005 IEEE ULTRASONICS SYMPOSIUM, VOLS 1-4, 2005, : 1703 - 1707
  • [9] ROLE OF CONTRAST-ENHANCED ULTRASOUND IN DIAGNOSIS OF THYROID NODULES IN ACOUSTIC RADIATION FORCE IMPULSE "GRAY ZONE''
    Zhan, Jia
    Diao, Xue-Hong
    Chen, Lin
    Jin, Jia-Mei
    Chen, Yue
    ULTRASOUND IN MEDICINE AND BIOLOGY, 2017, 43 (06): : 1179 - 1186
  • [10] Combination of acoustic radiation force impulse imaging, serological indexes and contrast-enhanced ultrasound for diagnosis of liver lesions
    Xiao-Lan Sun
    Hui Yao
    Qiong Men
    Ke-Zhu Hou
    Zhen Chen
    Chang-Qing Xu
    Li-Wei Liang
    World Journal of Gastroenterology, 2017, (30) : 5602 - 5609