Autopsy of RO desalination membranes Part 1. Microbial characterization of foulants

被引:4
|
作者
Schaule, G. [1 ]
Rapenne, S. [2 ]
Strathmann, M. [1 ]
Grobe, S. [1 ]
Robert, C. [2 ]
Jacquemet, V. [2 ]
机构
[1] IWW Water Ctr, Dept Appl Microbiol, D-45476 Mulheim, Germany
[2] Anjou Rech Veolia Environm, F-78600 Maisons Laffitte, France
关键词
Desalination; Membrane fouling; Iron-oxidising bacteria; Manganese-oxidising bacteria;
D O I
10.5004/dwt.2009.780
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Comprehensive autopsies of RO membrane elements from a seawater desalination plant were performed before and after chemical cleaning. The RO membrane elements (FILMTEC, SW3014R LE-400 8 '') selected for the autopsy studies have been in service for nearly 2 years and were located in front position of a pressure vessel from the first pass of one of the RO units. Process performances have been quite stable for the whole period of operation. Before and after chemical cleaning both membrane elements showed a visible deposit on the membrane surfaces with wet matter of 27 g/m(2) (before) and 11 g/m(2) (after) cleaning. By ICP-OES analyses before cleaning, a high content of iron and manganese was found in the deposit. After chemical cleaning, most of the parameters remained stable except the manganese content which was not detected any more. The autopsies underlined the presence of a biofilm even if no obvious loss of membrane performances was observed. The high content of manganese and iron in combination with the microscopic image of the layer indicated the presence of manganese and iron-oxidising bacteria together with their metabolites. Chemical cleaning seems to have a limited impact on this type of biofouling despite the improvement observed on pressure drops.
引用
收藏
页码:66 / 72
页数:7
相关论文
共 50 条
  • [1] Characterization of foulants by autopsy of RO desalination membranes
    Butt, FH
    Rahman, F
    Baduruthamal, U
    DESALINATION, 1997, 114 (01) : 51 - 64
  • [2] Autopsy of RO desalination membranes Part 2. Chemical characterisation
    Mondamert, L.
    Labanowski, J.
    Berjeaud, J. M.
    Rapenne, S.
    Croue, J. P.
    DESALINATION AND WATER TREATMENT, 2009, 9 (1-3) : 73 - 81
  • [3] Characterization and analysis of inorganic foulants in RO membranes for groundwater treatment
    Agnihotri, Bhuvneshwar
    Sharma, Aditya
    Gupta, Akhilendra B.
    DESALINATION, 2020, 491
  • [4] Economics of seawater RO desalination in the Red Sea region, Egypt. Part 1. A case study
    Hafez, A
    El-Manharawy, S
    DESALINATION, 2003, 153 (1-3) : 335 - 347
  • [5] Hollow fine fiber vs. spiral wound RO desalination membranes Part 1: Pilot plant evaluation
    King Fahd Univ of Petroleum and, Minerals, Dhahran, Saudi Arabia
    Desalination, 1 (67-82):
  • [6] Characterization of marine organic matters and heavy metals with respect to desalination with RO and NF membranes
    Lee, Sungyun
    Lee, Eunkyung
    Ra, Jinsung
    Lee, Byungcheon
    Kim, Suhan
    Choi, Seok Ho
    Kim, Sang Don
    Cho, Jaeweon
    DESALINATION, 2008, 221 (1-3) : 244 - 252
  • [7] Gravity-driven microfiltration pretreatment for reverse osmosis (RO) seawater desalination: Microbial community characterization and RO performance
    Wu, Bing
    Suwarno, Stanislaus Raditya
    Tan, Hwee Sin
    Kim, Lan Hee
    Hochstrasser, Florian
    Chong, Tzyy Haur
    Burkhardt, Michael
    Pronk, Wouter
    Fane, Anthony G.
    DESALINATION, 2017, 418 : 1 - 8
  • [8] Hollow fine fiber vs. spiral-wound RO desalination membranes .1. Pilot plant evaluation
    Butt, FH
    Rahman, F
    Baduruthamal, U
    DESALINATION, 1997, 109 (01) : 67 - 82
  • [9] Polyamide-based composite membranes: Part 1. Preparation and characterization
    Al-Rawajfeh, AE
    DESALINATION, 2005, 179 (1-3) : 265 - 272
  • [10] Fouling characterization of RO membranes after 11 years of operation in a brackish water desalination plant
    Ruiz-Garcia, A.
    Melian-Martel, N.
    Mena, V.
    DESALINATION, 2018, 430 : 180 - 185