Air, inflammation and biocompatibility of the extracorporeal circuits

被引:8
|
作者
Condello, Ignazio [1 ]
Santarpino, Giuseppe [1 ,2 ,3 ]
Nasso, Giuseppe [1 ]
Fiore, Flavio [1 ]
Moscarelli, Marco [1 ]
Mastroroberto, Pasquale [3 ]
Speziale, Giuseppe [1 ]
机构
[1] GVM Care & Res, Anthea Hosp, Dept Cardiac Surg, Bari, Italy
[2] Paracelsus Med Univ, Nurnberg, Germany
[3] Magna Graecia Univ Catanzaro, Dept Expt & Clin Med, Cardiac Surg Unit, Catanzaro, Italy
来源
PERFUSION-UK | 2021年 / 36卷 / 08期
关键词
air; inflammation; biocompatibility; extracorporeal circulation; coating; ALBUMIN;
D O I
10.1177/0267659120968364
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The inflammatory response in cardiac surgery using extracorporeal circulation (ECC) has been widely discussed in the literature with analysis on cytokines released in humans; demonstrating manifold trigger causes. To mitigate this response-mainly linked to the contact and recognition by the blood of a "non-self" surface-many efforts have been made to make the circuits of the extra-corporeal circulation "biomimetics"; trying to emulate the cardio-vascular system. In other words, biomedical companies have developed many biocompatible products in order to reduce the invasiveness of the ECC. One of the techniques used to reduce the contact of blood with "nonself" surfaces is the "coating" of the internal surfaces of the ECC. This can be done with phospholipidic, electrically neutral, and heparin derivates with anticoagulant activity. The coating can be divided into two categories: the "passive coating" with Phosphorylcholine by biomedical companies and the administration of albumin added to the "priming" during the filling of the circuit by the perfusionist. Alternatively, we have the "active" coating: treatment of the internal surfaces in contact with the blood with neutral proteins and heparin. The latter are different according to the production company, but the aim is always to maintain high levels of systemic and local anticoagulation, inactivating the "contact" coagulation between the blood and the surfaces. A recent study demonstrates that the use of an "active coating" is associated with better preservation of the endothelial glycocalyx compared with "passive coating" circuits.
引用
收藏
页码:781 / 785
页数:5
相关论文
共 50 条
  • [1] SMARxT and blood air interface -: a new concept to improve biocompatibility of extracorporeal circuits
    Isgro, F
    Kiessling, AH
    Saggau, W
    CURRENT PERSPECTIVES OF THE EXTRACORPOREAL CIRCULATION, 2000, : 77 - 82
  • [2] Biocompatibility in heparin-coated extracorporeal circuits
    Hsu, Li-Chien
    PERFUSION-UK, 1996, 11 (03): : 256 - 263
  • [3] BIOCOMPATIBILITY OF EXTRACORPOREAL CIRCUITS IN HEART-SURGERY
    VANOEVEREN, W
    WILDEVUUR, CRH
    KAZATCHKINE, MD
    TRANSFUSION SCIENCE, 1990, 11 (01): : 5 - 33
  • [4] Clinical performance and biocompatibility of poly(2-methoxyethylacrylate)-coated extracorporeal circuits
    Gunaydin, S
    Farsak, B
    Kocakulak, M
    Sari, T
    Yorgancioglu, C
    Zorlutuna, Y
    ANNALS OF THORACIC SURGERY, 2002, 74 (03): : 819 - 824
  • [5] INDUCTION OF INTERLEUKIN-1 SYNTHESIS - A NEW CRITERION OF BIOCOMPATIBILITY OF EXTRACORPOREAL CIRCUITS
    HAEFFNERCAVAILLON, N
    KAZATCHKINE, MD
    PRESSE MEDICALE, 1991, 20 (17): : 797 - 801
  • [6] Effects of new polymer-coated extracorporeal circuits on biocompatibility during cardiopulmonary bypass
    Saito, N
    Motoyama, S
    Sawamoto, J
    ARTIFICIAL ORGANS, 2000, 24 (07) : 547 - 554
  • [7] Biocompatibility of heparin-coated extracorporeal bypass circuits: A randomized, masked clinical trial
    Muehrcke, DD
    McCarthy, PM
    KottkeMarchant, K
    Harasaki, H
    PierreYared, J
    Borsh, JA
    Ogella, DA
    Cosgrove, DM
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1996, 112 (02): : 472 - 483
  • [8] PREVENTION OF AIR EMBOLISM DUE TO TRAPPED AIR IN FILTERS USED IN EXTRACORPOREAL CIRCUITS
    WELLONS, HA
    NOLAN, SP
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1973, 65 (03): : 476 - 478
  • [9] Nitric oxide gas infusion to the oxygenator enhances the biocompatibility of heparin coated extracorporeal bypass circuits
    Hayashi, Y
    Sawa, Y
    Nishimura, M
    Chang, JC
    Amemiya, A
    Kagisaki, K
    Taketani, S
    Yamaguchi, T
    Hirata, N
    Ohtake, S
    Matsuda, H
    ASAIO JOURNAL, 1998, 44 (05) : M456 - M461
  • [10] BIOCOMPATIBILITY OF EXTRACORPOREAL-CIRCULATION - INVITRO COMPARISON OF HEPARIN-COATED AND UNCOATED OXYGENATOR CIRCUITS
    VIDEM, V
    MOLLNES, TE
    GARRED, P
    SVENNEVIG, JL
    JOURNAL OF THORACIC AND CARDIOVASCULAR SURGERY, 1991, 101 (04): : 654 - 660