RELIABILITY OF A SEMI-AUTOMATIC ALGORITHM IN THE DETECTION OF CORTICAL BREAKS IN FINGER JOINTS USING HIGH RESOLUTION PERIPHERAL QUANTITATIVE CT

被引:1
|
作者
Peters, M. [1 ]
Scharmga, A. [1 ]
De Jong, J. [1 ]
Van Tubergen, A. [1 ]
Weijers, R. [2 ]
Loeffen, D. [2 ]
van den Rietbergen, B. [3 ]
van den Bergh, J. [1 ]
Geusens, P. [1 ]
机构
[1] MUMC, Rheumatol, Maastricht, Netherlands
[2] MUMC, Radiol, Maastricht, Netherlands
[3] TUE, Biomed Engn, Eindhoven, Netherlands
关键词
D O I
10.1136/annrheumdis-2016-eular.1714
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
FRI0539
引用
收藏
页码:635 / 635
页数:1
相关论文
共 50 条
  • [1] VALIDATION OF A SEMI-AUTOMATIC ALGORITHM FOR DEFINING CORTICAL BREAKS IN FINGER JOINTS USING HIGH-RESOLUTION PERIPHERAL QUANTITATIVE CT BY MICROCT
    Peters, M.
    Scharmga, A.
    Van Tubergen, A.
    Van Rietbergen, B.
    Weyers, R.
    Loeffen, D.
    Van den Bergh, J.
    Geusens, P.
    ANNALS OF THE RHEUMATIC DISEASES, 2016, 75 : 634 - 635
  • [2] The Reliability of a Semi-automated Algorithm for Detection of Cortical Interruptions in Finger Joints on High Resolution CT Compared to MicroCT
    Peters, M.
    Scharmga, A.
    van Tubergen, A.
    Arts, J.
    Loeffen, D.
    Weijers, R.
    van Rietbergen, B.
    Geusens, P.
    van den Bergh, J. P.
    CALCIFIED TISSUE INTERNATIONAL, 2017, 101 (02) : 132 - 140
  • [3] The Reliability of a Semi-automated Algorithm for Detection of Cortical Interruptions in Finger Joints on High Resolution CT Compared to MicroCT
    M. Peters
    A. Scharmga
    A. van Tubergen
    J. Arts
    D. Loeffen
    R. Weijers
    B. van Rietbergen
    P. Geusens
    J. P. van den Bergh
    Calcified Tissue International, 2017, 101 : 132 - 140
  • [4] Visual detection of cortical breaks in hand joints: reliability and validity of high-resolution peripheral quantitative CT compared to microCT
    Scharmga, A.
    Peters, M.
    van Tubergen, A.
    van den Bergh, J.
    de Jong, J.
    Loeffen, D.
    van Rietbergen, B.
    Weijers, R.
    Geusens, P.
    BMC MUSCULOSKELETAL DISORDERS, 2016, 17
  • [5] Visual detection of cortical breaks in hand joints: reliability and validity of high-resolution peripheral quantitative CT compared to microCT
    A. Scharmga
    M. Peters
    A. van Tubergen
    J. van den Bergh
    J. de Jong
    D. Loeffen
    B. van Rietbergen
    R. Weijers
    P. Geusens
    BMC Musculoskeletal Disorders, 17
  • [6] An automated algorithm for the detection of cortical interruptions on high resolution peripheral quantitative computed tomography images of finger joints
    Peters, M.
    Scharmga, A.
    de Jong, J.
    van Tubergen, A.
    Geusens, P.
    Arts, J. J.
    Loeffen, D.
    Weijers, R.
    van Rietbergen, B.
    van den Bergh, J.
    PLOS ONE, 2017, 12 (04):
  • [7] A Semi-Automated Method for Defining Cortical Bone Breaks in Cadaveric Finger Joints using High-Resolution peripheral QCT and MicroCT.
    Peters, Michiel
    Scharmga, Andrea
    Van Tubergen, Astrid
    Van Den Bergh, Joop
    Arts, Chris
    Rietbergen, Bert
    Geusens, Piet
    JOURNAL OF BONE AND MINERAL RESEARCH, 2014, 29 : S214 - S214
  • [8] ASSESSMENT OF BONE DENSITY, STRUCTURE, AND CORTICAL INTERRUPTIONS OF FINGER JOINTS IN PATIENTS WITH RHEUMATOID ARTHRITIS USING HIGH-RESOLUTION PERIPHERAL QUANTITATIVE CT
    Peters, M.
    Scharmga, A.
    van Tubergen, A.
    Loeffen, D.
    Weijers, R.
    van Rietbergen, B.
    Geusens, P.
    van den Bergh, J.
    ANNALS OF THE RHEUMATIC DISEASES, 2017, 76 : 740 - 740
  • [9] An automated algorithm for the detection of cortical interruptions on high resolution peripheral quantitative computed tomography images of finger joints (vol 12, e0175829, 2017)
    Peters, M.
    Scharmga, A.
    de Jong, J.
    van, Tubergen A.
    Geusens, P.
    Arts, J. J.
    PLOS ONE, 2017, 12 (06):
  • [10] Semi-Automatic Road Detection in High-Resolution Satellite Images
    Karaomeroglu, Betul
    Baseski, Emre
    2014 22ND SIGNAL PROCESSING AND COMMUNICATIONS APPLICATIONS CONFERENCE (SIU), 2014, : 1869 - 1872