Seismic structure-soil-structure interaction between pairs of adjacent building structures

被引:59
|
作者
Knappett, J. A. [1 ]
Madden, P. [1 ]
Caucis, K. [1 ,2 ]
机构
[1] Univ Dundee, Dundee, Scotland
[2] Arup, Edinburgh, Midlothian, Scotland
来源
GEOTECHNIQUE | 2015年 / 65卷 / 05期
基金
英国工程与自然科学研究理事会;
关键词
centrifuge modelling; earthquakes; numerical modelling; sands;
D O I
10.1680/geot.SIP.14.P.059
中图分类号
P5 [地质学];
学科分类号
0709 ; 081803 ;
摘要
Structure-soil-structure interaction between adjacent structures, which may occur in densely populated urban areas, has received little attention compared to the soil-structure interaction of single isolated structures. Additionally, recent earthquakes in/near such areas (e.g. the Christchurch series, 2010-2011) have shown that large motions can be followed by strong aftershocks. In this paper, the seismic behaviour of isolated structures and pairs of adjacent structures under a sequence of strong ground motions has been investigated using a combination of centrifuge and finite-element modelling. The latter utilised an advanced constitutive model that can be parameterised from routine test data, making it suitable for use in routine design. The finite-element models were shown to accurately simulate the centrifuge-measured response (in terms of surface ground motion and structural sway, settlement and rotation) even after multiple strong aftershocks, so long as the buildings' initial conditions were reproduced accurately. For the case of a building structure with a close neighbour, structural drift and co-seismic settlement could be reduced or increased as a result of structure-soil-structure interaction, depending chiefly on the properties of the adjacent structure. This suggests that careful arrangement of adjacent structures and specification of their properties could be used to control the effects of structure-soil-structure interaction. In all cases where adjacent structures were present, permanent rotation (structural tilt) was observed to increase significantly, demonstrating the importance of considering structure-soil-structure interaction in assessing the seismic performance of structures.
引用
收藏
页码:429 / 441
页数:13
相关论文
共 50 条
  • [1] Effects of seismic pounding between adjacent structures considering structure-soil-structure interaction
    Kermani, M.
    Saadatpour, M.M.
    Behnamfar, F.
    Ghandil, M.
    [J]. Scientia Iranica, 2020, 27 (05) : 2230 - 2246
  • [2] Effects of seismic pounding between adjacent structures considering structure-soil-structure interaction
    Kermani, M.
    Saadatpour, M. M.
    Behnamfar, F.
    Ghandil, M.
    [J]. SCIENTIA IRANICA, 2020, 27 (06) : 2230 - 2246
  • [3] Higher mode seismic structure-soil-structure interaction between adjacent building during earthquakes
    Vicencio, Felipe
    Alexander, Nicholas A.
    [J]. ENGINEERING STRUCTURES, 2018, 174 : 322 - 337
  • [4] Seismic Structure-Soil-Structure Interaction between inelastic structures
    Vicencio, Felipe
    Alexander, Nicholas A.
    Malaga-Chuquitaype, Christian
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2024, 53 (04): : 1446 - 1464
  • [5] Influence of structure-soil-structure interaction on seismic response and seismic migration performance of building structures
    Wu, Yangzhou
    Gao, Zhidong
    Zhao, Mi
    Du, Xiuli
    [J]. Journal of Building Engineering, 2024, 98
  • [6] Structure-soil-structure interaction of adjacent buildings subjected to seismic loading
    Bybordiani, Milad
    Arici, Yalin
    [J]. EARTHQUAKE ENGINEERING & STRUCTURAL DYNAMICS, 2019, 48 (07): : 731 - 748
  • [7] Seismic structure-soil-structure interaction between two different adjacent piled bridges founded in nonlinear soil
    Alfach, Mohanad Talal
    [J]. GEOMECHANICS AND GEOENGINEERING-AN INTERNATIONAL JOURNAL, 2022, 17 (04): : 1200 - 1229
  • [8] Numerical investigations of structure-soil-structure interaction on footing forces due to adjacent building
    Chandrawanshi, Shrish
    Garg, Vivek
    [J]. EARTHQUAKES AND STRUCTURES, 2024, 26 (06) : 477 - 487
  • [9] Study on Dynamic Structure-Soil-Structure Interaction of Three Adjacent Tall Buildings Subjected to Seismic Loading
    Gan, Jinsong
    Li, Peizhen
    Liu, Qiang
    [J]. SUSTAINABILITY, 2020, 12 (01)
  • [10] Investigation of the structure-soil-structure interaction between two structures in centrifuge test
    Chonam National University, Yeosu, Korea, Republic of
    [J]. Lect. Notes Civ. Eng., 2366, (1151-1157):