Study on post-blowdown of hot leg large break loss-of-coolant-accident in the view of mass and energy release analysis

被引:2
|
作者
Hong, SJ
Park, GC
机构
[1] Seoul Natl Univ, Future & Challenge Tech Inc, Kwanak Gu, Seoul 151742, South Korea
[2] Seoul Natl Univ, Dept Nucl Engn, Kwanak Gu, Seoul 151742, South Korea
关键词
D O I
10.1016/S0029-5493(01)00452-6
中图分类号
TL [原子能技术]; O571 [原子核物理学];
学科分类号
0827 ; 082701 ;
摘要
This study conducted mass and energy release experiment for the hot leg large break loss-of-coolant-accident (LBLOCA) during post-blowdown with an integral test facility, Seoul National University Facility (SNUF), and its RELAP5 simulation. This facility simulated the Young Kwang Nuclear Power Plant Units 3 and 4 (YGN3&4) with volume ratio of 1:1140 based on Ishii's three level scaling. The experiments showed that safety injection (SI) water refilled the cold leg first and later the core. The SI water was vaporized in the core, which resulted in the repressurization of the reactor. This increase in pressure drove the water in the cold leg to flow up to half the height of the U tubes. However, since the water was drained back not long after, the release through the SG side broken section by evaporation was negligible. The SNUF experiment was assessed by RELAP5 simulations. Overall, the analysis of the post-blowdown phase showed that the transient of the primary pressure can be properly simulated by RELAP5 when a sufficient heat source is modeled. Consequently, the releases from reactor side broken section and steam generator side broken section were properly predicted. The pressure rise by steam generation in the core was partially well predicted. The release from the steam generator side broken section was predicted to be small except when there exists a large pressure difference between the primary system and the break boundary. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:43 / 58
页数:16
相关论文
共 43 条
  • [1] UNCERTAINTY ANALYSIS OF THE LARGE BREAK LOSS-OF-COOLANT ACCIDENT
    STRITAR, A
    MAVKO, B
    PROSEK, A
    ZEITSCHRIFT FUR ANGEWANDTE MATHEMATIK UND MECHANIK, 1993, 73 (7-8): : T854 - T856
  • [2] HOT ROD STATISTICAL METHOD FOR LARGE BREAK LOSS OF COOLANT ACCIDENT WITH CATHARE
    Keldenich, Magali
    Barbier, Anthony
    Grouhel, Marie-Christine
    Pignoly, Celine
    ICONE16: PROCEEDING OF THE 16TH INTERNATIONAL CONFERENCE ON NUCLEAR ENGINEERING - 2008, VOL 3, 2008, : 615 - 622
  • [3] Fractional scaling analysis of cladding temperature in large break loss of coolant accident
    Yan, B. H.
    Long, B.
    Li, L. G.
    Xing, J.
    Lu, D. H.
    NUCLEAR ENGINEERING AND DESIGN, 2024, 423
  • [4] Study on severe accident induced by large break loss of coolant accident for pressurized water reactor
    Department of Nuclear Science and Engineering, Naval University of Engineering, Wuhan 430033, China
    Yuanzineng Kexue Jishu, 2007, 5 (560-564):
  • [5] Simulated AP600 response to small-break loss-of-coolant-accident and non-loss-of-coolant-accident events: Analysis of SPES-2 integral test results
    Friend, MT
    Wright, RF
    Hundal, R
    Hochreiter, LE
    Ogrins, M
    NUCLEAR TECHNOLOGY, 1998, 122 (01) : 19 - 42
  • [6] Experimental determination of the boron concentration distribution in the primary circuit of a PWR after a postulated cold leg small break loss-of-coolant-accident with cold leg safety injection
    Kliema, S.
    Prasser, H. -M.
    Suehnel, T.
    Weiss, F-P.
    Hansen, A.
    NUCLEAR ENGINEERING AND DESIGN, 2008, 238 (07) : 1788 - 1801
  • [7] Analysis of Kuosheng large-break loss-of-coolant accident with MELCOR 1.8.4
    Wang, TC
    Wang, SJ
    Chien, CS
    NUCLEAR TECHNOLOGY, 2000, 131 (03) : 319 - 331
  • [8] Fluid-structure interaction analysis of large-break loss of coolant accident
    Brandt, Tellervo
    Lestinen, Ville
    Toppila, Timo
    Kahkonen, Jukka
    Timperi, Antti
    Pattikangas, Timo
    Karppinen, Ismo
    NUCLEAR ENGINEERING AND DESIGN, 2010, 240 (09) : 2365 - 2374
  • [9] Safety Analysis of Large Break Loss of Coolant Accident of PWR Nuclear Power Plant
    Ma S.
    Yin H.
    He X.
    Li J.
    Meng Y.
    Yang X.
    Jiang S.
    Yuanzineng Kexue Jishu/Atomic Energy Science and Technology, 2019, 53 (06): : 1036 - 1043
  • [10] Integral test and engineering analysis of coolant depletion during a large-break loss-of-coolant accident
    Kim, YS
    Park, CH
    Bae, BU
    Park, GC
    Suh, KY
    Lee, UC
    NUCLEAR TECHNOLOGY, 2005, 149 (02) : 200 - 216