Measurement of activity distribution in an Am-241 disc source using peeled-off Gafchromic EBT3 films

被引:8
|
作者
Lee, Kwang-Ho [1 ]
Shin, Ji-Yong [1 ]
Kim, Eun-Hee [1 ]
机构
[1] Seoul Natl Univ, Dept Nucl Engn, 1 Gwanak Ro, Seoul 08826, South Korea
关键词
RI disc source; EBT film dosimetry; Alpha particle irradiator; Activity distribution; Dose distribution; ALPHA-PARTICLE IRRADIATOR; DOSIMETRY; CELLS; EXPOSURE; PROTON; CALIBRATION; DESIGN; BEAM; RAYS;
D O I
10.1016/j.apradiso.2018.01.037
中图分类号
O61 [无机化学];
学科分类号
070301 ; 081704 ;
摘要
Commercial alpha-emitting sources are fabricated mainly in a disc type. An alpha particle irradiator in Radiation Bioengineering Laboratory at Seoul National University was installed with an Am-241 disc source. Commercial Am-241 disc sources are fabricated by incorporating the radioactive element into a thin substrate layer. Those disc sources are utilized assuming that the radioactive element is uniformly distributed in the active layer of disc sources. In this study, we employed peeled-off Gafchromic EBT3 films to investigate the uniformity of areal radioactivity density over the disc source and to measure the effect of non-uniform activity distribution on dose distribution at the bottom of the cell culture dish positioned in a varying distance from the source. The measurements with the peeled-off EBT3 films informed that the areal activity density in the disc source differed by up to approximately 45% from the average. However, the inhomogeneous Am-241 distribution in a disc source did not affect the radial distribution of fluence rate at the inner bottom of cell dish when the dish is apart from the source sufficiently. The dose distribution measured with an EBT3 film nearly accorded with that obtained by Monte Carlo simulation assuming the uniform Am-241 activity distribution in the active layer of the disc source. Finally, the dose to a single-cell layer of 5 pm in a nominal thickness was obtained by Monte Carlo simulation assuming a uniform Am-241 activity distribution in the disc source at distances of 20 and 30 mm from the source. The cellular dose estimates were higher than the film dose estimates at all radial distances. The cellular dose decreased with an increasing radial distance from the center to a smaller extent than the EBT3 film dose did.
引用
下载
收藏
页码:192 / 200
页数:9
相关论文
共 43 条
  • [1] Quality assurance of alpha-particle dosimetry using peeled-off Gafchromic EBT3® film
    Ng, C. Y. P.
    Chun, S. L.
    Yu, K. N.
    RADIATION PHYSICS AND CHEMISTRY, 2016, 125 : 176 - 179
  • [2] Measurement of low energy beta radiation from Ni-63 by using peeled-off Gafchromic EBT3 film
    Ji, Wanook
    Kim, Jong-Bum
    Kim, Jin-Joo
    NUCLEAR ENGINEERING AND TECHNOLOGY, 2022, 54 (10) : 3811 - 3815
  • [3] Alpha particle exposure using EBT3 GafChromic film: film splitting radiation dosimetry for Am-241
    Morrison, Hali
    Danforth, John M.
    Stanley, Fintan K. T.
    Berger, N. Daniel
    Pearson, Dustin D.
    Pierce, Greg
    Goodarzi, Aaron A.
    Ploquin, Nicolas
    MEDICAL PHYSICS, 2019, 46 (11) : 5390 - 5390
  • [4] Submillimeter Dose Measurement with Gafchromic EBT2 and EBT3 Films
    Corradini, N.
    Presilla, S.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [5] Study On the Effective Depth of Measurement for Gafchromic EBT2 and EBT3 Films
    Corradini, N.
    Presilla, S.
    Sterpin, E.
    MEDICAL PHYSICS, 2013, 40 (06)
  • [6] Measuring diffuse ultraviolet exposures using Gafchromic EBT3 films
    Tsang, P. Y.
    Chan, P. M.
    Yu, K. N.
    RESULTS IN PHYSICS, 2017, 7 : 1492 - 1493
  • [7] Evaluation of the accuracy of Cyberknife tumor tracking using gafchromic EBT3 films
    Mastella, E.
    Vigorito, S.
    Rondi, E.
    Cattani, F.
    Piperno, G.
    Ferrari, A. M.
    Rozza, D.
    Strata, E.
    Orecchia, R.
    RADIOTHERAPY AND ONCOLOGY, 2015, 115 : S415 - S415
  • [8] GafChromic® EBT3 films for patient specific IMRT QA using amultichannel approach
    Marrazzo, Livia
    Zani, Margherita
    Pallotta, Stefania
    Arilli, Chiara
    Casati, Marta
    Compagnucci, Antonella
    Talamonti, Cinzia
    Bucciolini, Marta
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (08): : 1035 - 1042
  • [9] In Vivo Peripheral Dose Measurements in IMRT and CyberKnife Treatments Using Gafchromic EBT3 Films
    Ganapathy, K.
    Murali, V
    Muthukumaran, M.
    Velmurugan, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 2899 - 2899
  • [10] Assessment of clinically relevant dose distributions in pelvic IOERT using Gafchromic EBT3 films
    Costa, Filipa
    Sarmento, Sandra
    Sousa, Olga
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2015, 31 (07): : 692 - 701