Percutaneous Radiofrequency Ablation with Internally Cooled versus Internally Cooled Wet Electrodes for Small Subphrenic Hepatocellular Carcinomas

被引:12
|
作者
Kim, Jin Hyoung
Kim, Pyo Nyun [1 ]
Won, Hyung Jin
Shin, Yong Moon
机构
[1] Univ Ulsan, Coll Med, Dept Radiol, Seoul 138736, South Korea
关键词
HEPATIC-TUMORS; LOCAL RECURRENCE; THERMAL ABLATION; TISSUE ABLATION; SINGLE SESSION; RISK-FACTORS; DIAPHRAGM; CHEMOEMBOLIZATION; EXPERIENCE; FREQUENCY;
D O I
10.1016/j.jvir.2012.11.025
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
Purpose: To compare retrospectively technical effectiveness and complications after radiofrequency (RF) ablation with internally; cooled wet (ICW) electrodes versus conventional internally cooled (IC) electrodes in patients with Small (<= 3 cm) subphrenic hepatocellular carcinomas (HCCs). Materials and Methods: From March 2008 to January 2012, 165 patients, each with a single small subphrenic HCC, were treated with RF ablation using IC (n = 81) or ICW (n = 84) electrodes. Results: After initial RV ablation, technical success was achieved in 88% of patients treated with IC electrodes and 91% of patients treated with ICW electrodes (P = .623). At 1 month, technical effectiveness was achieved in 93% and 99% (P = .061). Mean ablation volume was significantly greater in patients treated with ICW electrodes compared with patients treated with IC electrodes, using 2-cm (14.5 cm(3) vs 6.2 cm(3); P = .001) and 3-cm (32.7 cm(3) vs 15.2 cm(3); P < .001) exposed tips. The 6-month and 1-, 2-, and 4-year local tumor progression rates were significantly lower after RF ablation with;ICW electrodes (5%, 13%, 15%, and 26%) compared with IC electrodes (11%, 24%, 32%, and 35%; P = .044). Major complications occurred in 6% of patient treated with IC electrodes and 2% of patients treated with ICW electrodes. Conclusions: In the treatment of small subphrenic HCCs, percutaneous RF ablation using ICW electrodes results in larger ablation zones and lower rates of local tumor progression than RF ablation using conventional IC electrodes.
引用
收藏
页码:351 / 356
页数:6
相关论文
共 50 条
  • [1] Percutaneous Radiofrequency Ablation Using Internally Cooled Wet Electrodes for the Treatment of Hepatocellular Carcinoma
    Kim, Jin Hyoung
    Kim, Pyo Nyun
    Won, Hyung Jin
    Shin, Yong Moon
    [J]. AMERICAN JOURNAL OF ROENTGENOLOGY, 2012, 198 (02) : 471 - 476
  • [2] Percutaneous Radiofrequency Ablation of Hepatocellular Carcinomas Adjacent to the Gallbladder with Internally Cooled Electrodes: Assessment of Safety and Therapeutic Efficacy
    Kim, Sang Won
    Rhim, Hyunchul
    Park, Mihyun
    Kim, Heejung
    Kim, Young-sun
    Choi, Dongil
    Lim, Hyo K.
    [J]. KOREAN JOURNAL OF RADIOLOGY, 2009, 10 (04) : 366 - 376
  • [3] Radiofrequency ablation with internally cooled versus perfused electrodes for the treatment of small hepatocellular carcinoma in patients with cirrhosis
    Seror, Olivier
    N'Kontchou, Gisele
    Tin-Tin-Htar, Myint
    Barrucand, Corinne
    Ganne, Nathalie
    Coderc, Emmanuelle
    Trinchet, Jean Claude
    Sellier, Nicolas
    Beaugrand, Michel
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2008, 19 (05) : 718 - 724
  • [4] Percutaneous radiofrequency ablation using internally cooled wet electrodes for the treatment of patients with lung tumors
    Iezzi, R.
    Larici, A. R.
    Posa, A.
    Carchesio, F.
    Congedo, M. T.
    Tagliaferri, L.
    Cassano, A.
    D'argento, E.
    Mantini, G.
    Rodolfino, E.
    Margaritora, S.
    Bria, E.
    Tortora, G.
    Valentini, V.
    Manfredi, R.
    [J]. EUROPEAN REVIEW FOR MEDICAL AND PHARMACOLOGICAL SCIENCES, 2019, 23 (15) : 6554 - 6561
  • [5] Percutaneous radiofrequency ablation using internally cooled wet electrodes for treatment of colorectal liver metastases
    Yoon, H. M.
    Kim, J. H.
    Shin, Y. M.
    Won, H. J.
    Kim, P. N.
    [J]. CLINICAL RADIOLOGY, 2012, 67 (02) : 122 - 127
  • [6] Radiofrequency Ablation Zones in Ex Vivo Bovine and In Vivo Porcine Livers: Comparison of the Use of Internally Cooled Electrodes and Internally Cooled Wet Electrodes
    Cha, Jihoon
    Choi, Dongil
    Lee, Min Woo
    Rhim, Hyunchul
    Kim, Young-sun
    Lim, Hyo K.
    Yoon, Jung Hwan
    Park, Cheol Keun
    [J]. CARDIOVASCULAR AND INTERVENTIONAL RADIOLOGY, 2009, 32 (06) : 1235 - 1240
  • [7] Radiofrequency Ablation Zones in Ex Vivo Bovine and In Vivo Porcine Livers: Comparison of the Use of Internally Cooled Electrodes and Internally Cooled Wet Electrodes
    Jihoon Cha
    Dongil Choi
    Min Woo Lee
    Hyunchul Rhim
    Young-sun Kim
    Hyo K. Lim
    Jung Hwan Yoon
    Cheol Keun Park
    [J]. CardioVascular and Interventional Radiology, 2009, 32 : 1235 - 1240
  • [8] Radiofrequency renal ablation: In vivo comparison of internally cooled, multitined expandable and internally cooled perfusion electrodes
    Lee, JM
    Han, JK
    Chang, JM
    Chung, SY
    Son, KR
    Kim, SH
    Lee, JY
    Choi, BI
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2006, 17 (03) : 549 - 556
  • [9] Computational modeling of radiofrequency ablation with an internally cooled wet electrode
    Ewertowska, E.
    Quesada-Diez, R.
    Radosevic, A.
    Andaluz, A.
    Moll, X.
    Berjano, E.
    Burdio, F.
    Trujillo, M.
    [J]. EMBEC & NBC 2017, 2018, 65 : 1069 - 1072
  • [10] CT findings after radiofrequency ablation in rabbit livers: Comparison of internally cooled electrodes, perfusion electrodes, and internally cooled perfusion electrodes
    Kim, Seung Kwon
    Gu, Myung Seo
    Hong, Hyun Pyo
    Choi, Dongil
    Chae, Seoung Wan
    [J]. JOURNAL OF VASCULAR AND INTERVENTIONAL RADIOLOGY, 2007, 18 (11) : 1417 - 1427