Is greater than 145° of deep knee flexion under weight-bearing conditions safe after total knee arthroplasty? A FLUOROSCOPIC ANALYSIS OF JAPANESE-STYLE DEEP KNEE FLEXION

被引:17
|
作者
Niki, Y. [1 ]
Takeda, Y. [1 ]
Udagawa, K. [1 ]
Enomoto, H. [1 ]
Toyama, Y. [1 ]
Suda, Y. [1 ]
机构
[1] Keio Univ, Sch Med, Dept Orthopaed Surg, Shinjuku Ku, Tokyo 1608582, Japan
来源
BONE & JOINT JOURNAL | 2013年 / 95B卷 / 06期
关键词
POLYETHYLENE TIBIAL POST; IN-VIVO; KINEMATICS; FRACTURE;
D O I
10.1302/0301-620X.95B6.30757
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We investigated the characteristics of patients who achieved Japanese-style deep flexion (seiza-sitting) after total knee replacement (TKR) and measured three-dimensional positioning and the contact positions of the femoral and tibial components. Seiza-sitting was achieved after surgery by 23 patients (29 knees) of a series of 463 TKRs in 341 patients. Pre-operatively most of these patients were capable of seiza-sitting, had a lower body mass index and a favourable attitude towards the Japanese lifestyle (27 of 29 knees). According to two-/three-dimensional image registration analysis in the seiza-sitting position, flexion, varus and internal rotation angles of the tibial component relative to the femoral component had means of 148 (sip 8.0), 1.9 degrees (6D 3.2) and 13.4 degrees (SD 5.9), respectively. Femoral surface contact positions tended to be close to the posterior edge of the tibial polyethylene insert, particularly in the lateral compartment, but only 8.3% (two of 24) of knees showed femoral subluxation over the posterior edge. The mean contact positions of the femoral cam on the tibial post were located 7.8 mm (SD 1.5) proximal to the lowest point of the polyethylene surface and 5.5 mm (6D 0.9) medial to the centre of the post, indicating that the post-cam contact position translated medially during seiza-sitting, but not proximally. Collectively, the seiza-sitting position seems safe against component dislocation, but the risks of posterior edge loading and breakage of the tibial polyethylene post remain.
引用
收藏
页码:782 / 787
页数:6
相关论文
共 50 条
  • [1] Fluoroscopic and Computed Tomographic Analysis of Knee Kinematics During Very Deep Flexion After Total Knee Arthroplasty
    Nakamura, Shinichiro
    Takagi, Haruki
    Asano, Taiyo
    Nakagawa, Yasuaki
    Kobayashi, Masahiko
    Nakamura, Takashi
    JOURNAL OF ARTHROPLASTY, 2010, 25 (03): : 486 - 491
  • [2] Factors affecting the achievement of Japanese-style deep knee flexion after total knee arthroplasty using posterior-stabilized prosthesis with high-flex knee design
    Niki, Yasuo
    Takeda, Yuki
    Harato, Kengo
    Suda, Yasunori
    JOURNAL OF ORTHOPAEDIC SCIENCE, 2015, 20 (06) : 1012 - 1018
  • [3] Fluoroscopic analysis of knee arthroplasty kinematics during deep flexion kneeling
    Kanekasu, K
    Banks, SA
    Honjo, S
    Nakata, O
    Kato, H
    JOURNAL OF ARTHROPLASTY, 2004, 19 (08): : 998 - 1003
  • [4] Achieving Deep Flexion After Primary Total Knee Arthroplasty
    Tarabichi, Samih
    Tarabichi, Yasir
    Hawari, Marwan
    JOURNAL OF ARTHROPLASTY, 2010, 25 (02): : 219 - 224
  • [5] In vivo kinematics of mobile-bearing total knee arthroplasty during deep knee bending under weight-bearing conditions
    Kazuma Futai
    Tetsuya Tomita
    Takaharu Yamazaki
    Masashi Tamaki
    Hideki Yoshikawa
    Kazuomi Sugamoto
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19 : 914 - 920
  • [6] In vivo kinematics of mobile-bearing total knee arthroplasty during deep knee bending under weight-bearing conditions
    Futai, Kazuma
    Tomita, Tetsuya
    Yamazaki, Takaharu
    Tamaki, Masashi
    Yoshikawa, Hideki
    Sugamoto, Kazuomi
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (06) : 914 - 920
  • [7] Fluoroscopic analysis of the kinematics of deep flexion in total knee arthroplasty - Influence of posterior condylar offset
    Bellemans, J
    Banks, S
    Victor, J
    Vandenneucker, H
    Moemans, A
    JOURNAL OF BONE AND JOINT SURGERY-BRITISH VOLUME, 2002, 84B : 50 - 53
  • [8] Evaluation of the Contact Area in Total Knee Arthroplasty Designed for Deep Knee Flexion
    Triwardono, Joko
    Supriadi, Sugeng
    Whulanza, Yudan
    Saragih, Agung Shamsuddin
    Novalianita, Deva Ariana
    Utomo, Muhammad Satrio
    Kartika, Ika
    INTERNATIONAL JOURNAL OF TECHNOLOGY, 2021, 12 (06) : 1312 - 1322
  • [9] In-vivo patellar tendon kinematics during weight-bearing deep knee flexion
    Kobayashi, Koichi
    Sakamoto, Makoto
    Hosseini, Ali
    Rubash, Harry E.
    Li, Guoan
    JOURNAL OF ORTHOPAEDIC RESEARCH, 2012, 30 (10) : 1596 - 1603
  • [10] Does Greater Knee Flexion Increase Patient Function and Satisfaction After Total Knee Arthroplasty?
    Devers, Brandon N.
    Conditt, Michael A.
    Jamieson, Miranda L.
    Driscoll, Matthew D.
    Noble, Philip C.
    Parsley, Brian S.
    JOURNAL OF ARTHROPLASTY, 2011, 26 (02): : 178 - 186