On-orbit calibration and inter-comparison of Terra and Aqua MODIS surface temperature spectral bands

被引:26
|
作者
Xiong, X. [1 ]
Wu, A. [2 ]
Cao, C. [3 ]
机构
[1] NASA, Goddard Space Flight Ctr, Biospher Sci Branch, Greenbelt, MD 20771 USA
[2] Sci Syst & Applicat Inc, Lanham, MD 20706 USA
[3] NOAA, NESDIS, Ctr Satellite Applicat & Res, Camp Springs, MD 20746 USA
关键词
D O I
10.1080/01431160802036300
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Two moderate resolution imaging spectroradiometer (MODIS) instruments have been operating on board the NASA EOS Terra and Aqua spacecraft for 7 and 4.5 years, respectively. The MODIS is a cross-track scanning radiometer that collects data in 36 spectral bands with wavelengths from visible (VIS) to long-wave infrared (LWIR). MODIS thermal emissive bands (TEB) on-orbit calibration is performed using an on-board blackbody (BB). Bands 31 and 32, with centre wavelengths at 11 and 12 mu m, are primarily used for surface temperature (ST) retrieval. This paper provides a brief description of MODIS TEB calibration methodology and presents bands 31 and 32 on-orbit performance in terms of their calibration stability and detector noise characterization. It also describes an approach to examine the ST spectral band calibration consistency between two MODIS instruments using similar spectral channels of an advanced very high resolution radiometer (AVHRR) instrument currently operated on board NOAA-16 and NOAA-17. Inter-comparison data sets are carefully selected from near-simultaneous and near-nadir observations made by each pair of MODIS and AVHRR instruments. Results show that ST spectral bands 31 and 32 in both the Terra and Aqua MODIS are performing better than their design requirements, with excellent calibration stability and satisfactory cross-sensor calibration consistency. The on-orbit noise equivalent temperature differences (NEdTs) of all detectors have been continuously below the design specifications of 0.05 K. The calibration coefficients are extremely stable with scan-by-scan variations of less than 0.10%. In addition, calibration differences between two MODIS instruments are less than 0.10 K for both bands 31 and 32.
引用
收藏
页码:5347 / 5359
页数:13
相关论文
共 50 条
  • [1] Terra and Aqua MODIS Thermal Emissive Bands On-Orbit Calibration and Performance
    Xiong, Xiaoxiong
    Wu, Aisheng
    Wenny, Brian N.
    Madhavan, Sriharsha
    Wang, Zhipeng
    Li, Yonghong
    Chen, Na
    Barnes, William L.
    Salomonson, Vincent V.
    [J]. IEEE TRANSACTIONS ON GEOSCIENCE AND REMOTE SENSING, 2015, 53 (10): : 5709 - 5721
  • [2] An overview of inter-comparison methodologies for Terra and Aqua MODIS calibration
    Xiong, X.
    Wu, A.
    Sun, J.
    Wenny, B.
    [J]. EARTH OBSERVING SYSTEMS XI, 2006, 6296
  • [3] Terra and Aqua MODIS On-orbit Spectral Characterization for Reflective Solar Bands
    Choi, Taeyoung
    Xiong, Xiaxiong
    Wang, Zhipeng
    Link, Daniel
    [J]. OCEAN SENSING AND MONITORING V, 2013, 8724
  • [4] Inter-comparison of radiometric calibration of Terra and Aqua MODIS 11μm and 12 μm Bands
    Wu, AS
    Xiong, J
    Cao, CY
    Wu, F
    Barnes, B
    [J]. EARTH OBSERVING SYSTEMS IX, 2004, 5542 : 248 - 258
  • [5] On-orbit Performance and Calibration Improvements for the Reflective Solar Bands of Terra and Aqua MODIS
    Angal, Amit
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chen, Hongda
    Geng, Xu
    Link, Daniel
    Li, Yonghong
    Wald, Andrew
    Brinkmann, Jake
    [J]. EARTH OBSERVING MISSIONS AND SENSORS: DEVELOPMENT, IMPLEMENTATION, AND CHARACTERIZATION IV, 2016, 9881
  • [6] On-orbit calibration and performance assessments of Terra and Aqua MODIS thermal emissive bands
    Xiong, Xiaoxiong
    Wu, Aisheng
    Chang, Tiejun
    Wilson, Truman
    Li, Yonghong
    Chen, Na
    Shrestha, Ashish
    Diaz, Carlos Perez
    [J]. JOURNAL OF APPLIED REMOTE SENSING, 2021, 15 (01)
  • [7] Summary of Terra and Aqua MODIS on-orbit calibration and characterization results
    Xiong, Xiaoxiong
    Salomonson, Vince
    Wenny, B.
    Xie, X.
    Che, N.
    Wu, A.
    Barnes, William
    [J]. IGARSS: 2007 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-12: SENSING AND UNDERSTANDING OUR PLANET, 2007, : 4128 - +
  • [8] Assessments and Applications of Terra and Aqua MODIS On-orbit Electronic Calibration
    Xiong, Xiaoxiong
    Chen, Na
    Li, Yonghong
    Wilson, Truman
    [J]. EARTH OBSERVING SYSTEMS XXI, 2016, 9972
  • [9] Summary of Terra MODIS Thermal Emissive Bands On-orbit Calibration
    Xiong, X.
    Salomonson, V. V.
    Chiang, K.
    Chen, N.
    Xiong, S.
    Barnes, W. L.
    Guenther, Bruce
    [J]. 2006 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-8, 2006, : 3228 - +
  • [10] An Overview of Terra MODIS Reflective Solar Bands On-orbit Calibration
    Xiong, X.
    Salomonson, V. V.
    Barnes, W. L.
    Guenther, B.
    Xie, X.
    Sun, J.
    [J]. 2006 IEEE INTERNATIONAL GEOSCIENCE AND REMOTE SENSING SYMPOSIUM, VOLS 1-8, 2006, : 1111 - +