Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?

被引:3
|
作者
Froeling, Vera [1 ]
Heimann, Uwe [2 ]
Huebner, Ralf-Harto [3 ]
Kroencke, Thomas J. [4 ]
Maurer, Martin H. [5 ]
Doellinger, Felix [1 ]
Geisel, Dominik [1 ]
Hamm, Bernd [1 ]
Brenner, Winfried [2 ]
Schreiter, Nils F. [2 ]
机构
[1] Univ Med Berlin, Dept Radiol, Charite, Campus Virchow Klinikum, D-13353 Berlin, Germany
[2] Univ Med Berlin, Dept Nucl Med, Charite, Campus Virchow Klinikum, D-13353 Berlin, Germany
[3] Univ Med Berlin, Dept Internal Med Infect Dis & Resp Med, Charite, Campus Virchow Klinikum, D-13353 Berlin, Germany
[4] Klinikum Augsburg, Dept Diagnost Radiol & Neuroradiol, D-86156 Augsburg, Germany
[5] Univ Spital Bern, Inselspital, Dept Radiol Neuroradiol & Nucl Med DIPR, INO B, CH-3010 Bern, Switzerland
关键词
Attenuation correction; V/P SPECT/CT; Pulmonary emphysema; COLLATERAL VENTILATION; DISEASE; SCINTIGRAPHY; IMAGES; CT; TOMOGRAPHY;
D O I
10.1007/s12149-015-0976-4
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
To evaluate the utility of attenuation correction (AC) of V/P SPECT images for patients with pulmonary emphysema. Twenty-one patients (mean age 67.6 years) with pulmonary emphysema who underwent V/P SPECT/CT were included. AC/non-AC V/P SPECT images were compared visually and semiquantitatively. Visual comparison of AC/non-AC images was based on a 5-point likert scale. Semiquantitative comparison assessed absolute counts per lung (aCpLu) and lung lobe (aCpLo) for AC/non-AC images using software-based analysis; percentage counts (PC = (aCpLo/aCpLu) x 100) were calculated. Correlation between AC/non-AC V/P SPECT images was analyzed using Spearman's rho correlation coefficient; differences were tested for significance with the Wilcoxon rank sum test. Visual analysis revealed high conformity for AC and non-AC V/P SPECT images. Semiquantitative analysis of PC in AC/non-AC images had an excellent correlation and showed no significant differences in perfusion (rho = 0.986) or ventilation (rho = 0.979, p = 0.809) SPECT/CT images. AC of V/P SPECT images for lung lobe-based function imaging in patients with pulmonary emphysema do not improve visual or semiquantitative image analysis.
引用
收藏
页码:528 / 534
页数:7
相关论文
共 50 条
  • [1] Ventilation/perfusion SPECT or SPECT/CT for lung function imaging in patients with pulmonary emphysema?
    Vera Froeling
    Uwe Heimann
    Ralf-Harto Huebner
    Thomas J. Kroencke
    Martin H. Maurer
    Felix Doellinger
    Dominik Geisel
    Bernd Hamm
    Winfried Brenner
    Nils F. Schreiter
    [J]. Annals of Nuclear Medicine, 2015, 29 : 528 - 534
  • [2] Ventilation/perfusion SPECT/CT in patients with pulmonary emphysema - Evaluation of software based analyzing
    Froeling, Vera
    Doellinger, Felix
    Bredow, Jan
    Steffen, Ingo
    Poellinger, Alexander
    Huebner, Ralf-Harto
    Brenner, Winfried
    Schreiter, Nils
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [3] Ventilation/perfusion SPECT/CT in patients with pulmonary emphysema - Evaluation of software based analyzing
    Froeling, Vera
    Doellinger, Felix
    Bredow, Jan
    Steffen, Ingo
    Poellinger, Alexander
    Huebner, Ralf-Harto
    Brenner, Winfried
    Schreiter, Nils
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [4] Ventilation/perfusion SPECT/CT in patients with pulmonary emphysema Evaluation of software-based analysing
    Schreiter, V.
    Steffen, I.
    Huebner, H.
    Bredow, J.
    Heimann, U.
    Kroencke, T. J.
    Poellinger, A.
    Doellinger, F.
    Buchert, R.
    Hamm, B.
    Brenner, W.
    Schreiter, N. F.
    [J]. NUKLEARMEDIZIN-NUCLEAR MEDICINE, 2015, 54 (01): : 31 - 35
  • [5] Patients with pulmonary emphysema before endobronchial valve placement - Comparing ventilation/perfusion SPECT/CT and functional CT
    Froeling, Vera
    Doellinger, Felix
    Bredow, Jan
    Steffen, Ingo
    Pllinger, Alexander
    Huebner, Ralf-Harto
    Brenner, Winfried
    Schreiter, Nils
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2014, 55
  • [6] SPECT/CT imaging of lung perfusion in the diagnosis of pulmonary embolism: Comparison with planar ventilation-perfusion lung scintigraphy
    Revel, C.
    Poisson, T.
    Revel, A.
    Daragon, N.
    Grandpierre, S.
    Netter, F.
    Scigliano, S.
    Djaballah, W.
    Olivier, P.
    Karcher, G.
    Marie, P. -Y.
    [J]. MEDECINE NUCLEAIRE-IMAGERIE FONCTIONNELLE ET METABOLIQUE, 2008, 32 (06): : 313 - 322
  • [7] Lung SPECT Perfusion Scintigraphy: Can CT substitute for Ventilation imaging?
    Gradinscak, D.
    Roach, P. J.
    Schembri, G.
    Bailey, D.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2009, 36 : S300 - S300
  • [8] Diagnostic Performance of Perfusion-Only SPECT/CT for Chronic Thromboembolic Pulmonary Hypertension in Comparison With Ventilation-Perfusion Planar, SPECT, and SPECT/CT Imaging
    Sung, Changhwan
    Han, Sangwon
    Yoon, Soyoon
    Han, Shin Ae
    Kang, Do-Yoon
    Kim, Dae-Hee
    Park, Duk-Woo
    Song, Jong-Min
    Lee, Jae Seung
    Ryu, Jin-Sook
    Moon, Dae Hyuk
    [J]. CLINICAL NUCLEAR MEDICINE, 2024, 49 (05) : 427 - 433
  • [9] Diagnostic impact of pulmonary ventilation and perfusion SPECT/CT for differentiating lung diseases
    Tsukagoshi, T.
    Fukushima, Y.
    Hamana, T.
    Andou, T.
    Sugihara, Y.
    Kumita, S.
    [J]. EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2018, 45 : S385 - S386
  • [10] Diagnostic impact of pulmonary ventilation and perfusion SPECT/CT for differentiating lung diseases
    Tsukagoshi, Tomohiro
    Fukushima, Yoshimitsu
    Hamana, Teruhiko
    Ando, Takahiro
    Sugihara, Yasuro
    Kumita, Shin-ichiro
    [J]. JOURNAL OF NUCLEAR MEDICINE, 2018, 59