Titanium full crown casting: thermal expansion of investments and crown accuracy

被引:14
|
作者
Low, D [1 ]
Mori, T [1 ]
机构
[1] Univ Sydney, Natl Innovat Ctr, Fac Dent, Biomat Sci Res Unit, Amritsar 143005, Punjab, India
关键词
titanium castings; wax pattern and castings; thermal expansion; crown accuracy assessment;
D O I
10.1016/S0109-5641(99)00031-7
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Objectives: The aim of the present study was to establish a statistical model between thermal expansion values of investments and dimensional accuracy of cast titanium full crowns. Methods: Thermal expansion (TE) measurements were made on cylindrical specimens (5 empty set x 20 mm) dried to constant mass and full crown wax patterns were prepared from metal dies having the same design. Castings were made using a one-chamber high-pressure casting machine. Dimensional accuracy of the cast crowns was expressed by the discrepancy (mu m) between the wax pattern and a casting prepared from the same die. A simple least squares linear regression analysis was made on data accumulated over the last five years. Results: A high correlation coefficient (R = 0.87) was found between dimensional accuracy (Y) and thermal expansion value (X), and the accuracy was predicted by a formula Y = 1040.50X - 1004.45 mu m For zero discrepancy, a thermal expansion of 0.97% was required. Significance: The dimensional accuracy expressed as the discrepancy between wax pattern and casting is easy to understand and less confusing than the traditional percentage value. The crown accuracy was highly predictable (R = 0.87) from the thermal expansion value of investments determined under controlled laboratory measuring conditions. New investments being released for titanium casting can be under constant modification. For this, regular monitoring of their TE behaviour is essential and use of the same batch is preferable for expansion measurement and crown accuracy assessment. (C) 1999 Academy of Dental Materials. Published by Elsevier Science Ltd. All rights reserved.
引用
收藏
页码:185 / 190
页数:6
相关论文
共 50 条
  • [1] Thermal expansion and crown accuracy in titanium casting.
    Low, D
    Mori, T
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 : 345 - 345
  • [2] Setting expansion and dimensional accuracy of titanium full crown casting.
    Low, D
    Mori, T
    [J]. JOURNAL OF DENTAL RESEARCH, 1998, 77 (05) : 1132 - 1132
  • [3] Selection of thermal expansion values for titanium crown casting.
    Low, D
    Chung, HG
    Mori, T
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 : 367 - 367
  • [4] Thermal expansion typed investments for casting titanium
    Kitahara, K
    Kubo, F
    Takahashi, N
    [J]. DENTAL MATERIALS JOURNAL, 2004, 23 (01) : 1 - 7
  • [5] Modeling the investment casting of a titanium crown
    Atwood, R. C.
    Lee, P. D.
    Curtis, R. V.
    Maijer, D. M.
    [J]. DENTAL MATERIALS, 2007, 23 (01) : 60 - 70
  • [6] Influence of investment type and sprue number on the casting accuracy of titanium crown margins
    Leal, MB
    Paulino, SM
    Pagnano, VO
    Bezzon, OL
    [J]. JOURNAL OF PROSTHETIC DENTISTRY, 2006, 95 (01): : 42 - 49
  • [7] Titanium crown margin accuracy comparisons between different casting systems.
    Blackman, RB
    Baez, RJ
    Lopez, M
    Naffah, DM
    [J]. JOURNAL OF DENTAL RESEARCH, 1996, 75 : 1187 - 1187
  • [8] Comparison of titanium casting from full crown and metal-ceramic dies.
    Low, D
    Sumii, T
    [J]. JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 937 - 937
  • [9] Thermal expansion and crown evaluations in rolling processes
    Tseng, AA
    Tong, SX
    Chen, TC
    [J]. MATERIALS & DESIGN, 1996, 17 (04): : 193 - 204
  • [10] Thermal expansion coefficient of titanium casting
    Low, D
    Sumii, T
    Swain, M
    [J]. JOURNAL OF ORAL REHABILITATION, 2001, 28 (03) : 239 - 242