Impact of urban heat island on the variation of heating loads in residential and office buildings in Tianjin

被引:26
|
作者
Meng, Fanchao [1 ]
Guo, Jun [1 ]
Ren, Guoyu [2 ,3 ]
Zhang, Lei [4 ]
Zhang, Ruixue [5 ]
机构
[1] Tianjin Climate Ctr, 100 Qixiangtai Rd, Tianjin 300074, Peoples R China
[2] China Meteorol Adm, Lab Climate Studies, Natl Climate Ctr, Beijing 10081, Peoples R China
[3] China Univ Geosci, Sch Environm Studies, Dept Atmospher Sci, Wuhan 430074, Peoples R China
[4] China Meteorol Adm, Natl Meteorol Informat Ctr, Beijing 100081, Peoples R China
[5] China Acad Bldg Res, Beijing 100013, Peoples R China
关键词
Urban heat island; Rural weather station; Heating load; Office buildings; Residential buildings; COOLING ENERGY-CONSUMPTION; CLIMATE-CHANGE; THERMAL COMFORT; PERFORMANCE; VARIABILITY; SIMULATION; DEMAND; DESIGN; TRENDS; ROME;
D O I
10.1016/j.enbuild.2020.110357
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Urban heat island (UHI) significantly affects the energy demand of buildings. Therefore, it is important to consider UHI effect when evaluating the real energy demand of buildings in urban and rural areas. Based on hourly data observed over the past ten years from automatic weather stations and four representative rural weather stations selected by remote sensing method, the impact of the UHI intensity (UHII) on the building loads at fine time scales (i.e. day and hour) were evaluated by simulating the hourly loads during whole year of the typical residential and office buildings in urban and rural areas. UHII was found to be the main climatic factor affecting the variations in heating load in both residential and office buildings. With a heating-period mean UHII of 2.1 degrees C in the ten years, the daily heating load in urban areas is significantly lower than that in rural areas, which is 10.1 and 7.5% less for residential and office buildings, respectively. For residential and office buildings, the daily heating load has decreased by 34.2 x 10(-3) and 27.7 x 10(-3) kWh/m(2), respectively, for every 1 degrees C increase in UHII. For both types of buildings, the period of high energy consumption in both urban and rural areas was from late December to late January of the following year. The hourly load in residential buildings was high at night and low during the daytime, and the opposite was founded in office buildings. For residential buildings, the period from 18:00 one day to 07:00 the next day was the high load period in both urban and rural areas, whereas the high load period in office buildings was from 07:00 to 19:00. The peak load in residential and office buildings was founded from 05:00 to 07:00 and from 07:00 to 11:00, respectively. Overall, the daily and hourly heating load variations in residential and office buildings response to UHI should be fully considered to improve the fine-level of heating operation regulations, especially in urban areas, to reduce the energy consumption of buildings. (C) 2020 Elsevier B.V. All rights reserved.
引用
收藏
页数:10
相关论文
共 50 条
  • [1] Impact of Urban Heat Island under the Hanoi Master Plan 2030 on Cooling Loads in Residential Buildings
    Tran Hoang Hai Nam
    Kubota, Tetsu
    Trihamdani, Andhang Rakhmat
    [J]. INTERNATIONAL JOURNAL OF BUILT ENVIRONMENT AND SUSTAINABILITY, 2015, 2 (01): : 48 - 61
  • [2] Impact of urban heat island effect on building heating intensity in Tianjin, China
    Meng, Fanchao
    Li, Mingcai
    Guo, Jun
    Zhang, Lei
    Cao, Jingfu
    Chen, Yuehao
    [J]. INTERNATIONAL JOURNAL OF GLOBAL WARMING, 2020, 21 (01) : 20 - 34
  • [3] London's urban heat island: Impact on current and future energy consumption in office buildings
    Kolokotroni, M.
    Ren, X.
    Davies, M.
    Mavrogianni, A.
    [J]. ENERGY AND BUILDINGS, 2012, 47 : 302 - 311
  • [4] Cooling and heating loads in residential buildings in Jordan
    Shariah, A
    Tashtoush, B
    Rousan, A
    [J]. ENERGY AND BUILDINGS, 1997, 26 (02) : 137 - 143
  • [5] RESIDENTIAL COOLING LOADS AND THE URBAN HEAT-ISLAND - THE EFFECTS OF ALBEDO
    TAHA, H
    AKBARI, H
    ROSENFELD, A
    HUANG, J
    [J]. BUILDING AND ENVIRONMENT, 1988, 23 (04) : 271 - 283
  • [6] Urban heat island effect on energy application studies of office buildings
    Sun, Yuming
    Augenbroe, Godfried
    [J]. ENERGY AND BUILDINGS, 2014, 77 : 171 - 179
  • [7] Heating modes analysis of low energy residential buildings in Tianjin
    Lu, Yan
    Wang, Yanan
    Lu, You
    [J]. CUE 2015 - APPLIED ENERGY SYMPOSIUM AND SUMMIT 2015: LOW CARBON CITIES AND URBAN ENERGY SYSTEMS, 2016, 88 : 800 - 806
  • [8] The impact of the phoenix urban heat island on residential water use
    Guhathakurta, Subhrajit
    Gober, Patricia
    [J]. JOURNAL OF THE AMERICAN PLANNING ASSOCIATION, 2007, 73 (03) : 317 - 329
  • [9] Thermal behaviour of buildings: Modelling the impact of urban heat island
    Bozonnet, Emmanuel
    Belarbi, Rafik
    Allard, Francis
    [J]. Journal of Harbin Institute of Technology (New Series), 2007, 14 (SUPPL.) : 19 - 22
  • [10] IMPACT OF URBAN HEAT ISLAND DEVELOPMENT ON BUILDINGS' ENERGY CONSUMPTION
    Papanastasiou, Dimitris K.
    Fidaros, Dimitris
    Bartzanas, Thomas
    Kittas, Constantinos
    [J]. FRESENIUS ENVIRONMENTAL BULLETIN, 2013, 22 (7A): : 2087 - 2092