Sign of eye irritation in female hospital workers and the indoor environment

被引:38
|
作者
Smedbold, HT [2 ]
Ahlen, C
Norbäck, D
Hilt, B
机构
[1] Norwegian Univ Sci & Technol, Inst Environm Med, N-7006 Trondheim, Norway
[2] Univ Trondheim Hosp, Dept Occupat Med, N-7006 Trondheim, Norway
[3] Sintef Unimed, Sect Extreme Work Environm, Trondheim, Norway
[4] Univ Uppsala Hosp, Dept Occupat & Environm Med, Uppsala, Sweden
[5] Uppsala Univ, Dept Med Sci, Uppsala, Sweden
关键词
tear-film break-up time; vital staining; microbial flora; traffic pollution; dust settlement;
D O I
10.1034/j.1600-0668.2001.110403.x
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
The relationships between indoor environment factors and signs of eye irritation were studied in a sample of female personnel with (n=112) and without (n=64) mucous membrane symptoms working in 36 nursing departments at geriatric hospitals in the municipality of Trondheim, Norway. The indoor climate was characterised by high room temperature (interquartile range 23.0-23.7 degreesC), low relative air humidity (interquartile range 17-26%) and high outdoor airflow rate, as indicated by low indoor levels of carbon dioxide (interquartile range 490-650 ppm). An altered microbial flora was observed in nine of the departments, and Aspergillus fumigatus was found in three of these. Five of the hospitals were situated in urban parts of the municipality near roads with heavy traffic. In the initial analyses decreased tear-film stability (BUT) was observed in subjects working in departments with increased dust settlement rate (P=0.03), in hospitals situated in urban areas with heavy traffic (P <0.001), and in subjects working in departments with presence of A. fumigatus (P=0.04). Increased conjunctival staining (CS) was related to alteration of the microbial flora. In the final multivariate analyses statistically significant relationships were observed between BUT and dust settlement rate and urban vicinity of workplace and between CS and alteration of the microbial flora.
引用
收藏
页码:223 / 231
页数:9
相关论文
共 50 条
  • [1] Eye irritation and cognition disorders in a hospital with aldehydes and glycol ethers as indoor contaminants
    Plieninger, P
    Höfer, T
    GEFAHRSTOFFE REINHALTUNG DER LUFT, 2001, 61 (11-12): : 521 - 527
  • [2] Eye irritation and cognition disorders in a hospital with aldehydes and glycol ethers as indoor contaminants
    Plleninger, P.
    Höfer, T.
    Gefahrstoffe Reinhaltung der Luft, 2001, 61 (11-12): : 521 - 527
  • [3] Complaints of indoor workers as reflection of inadequate indoor environment
    Soon, A
    Indermitte, E
    Kähkönen, E
    PROCEEDINGS OF THE SECOND NSF INTERNATIONAL CONFERENCE ON INDOOR AIR HEALTH: TRENDS AND ADVANCES IN RISK ASSESSMENT AND MANAGEMENT, 2001, : 55 - 62
  • [4] Burnout among female indoor sex workers
    Vanwesenbeeck, I
    ARCHIVES OF SEXUAL BEHAVIOR, 2005, 34 (06) : 627 - 639
  • [5] Burnout Among Female Indoor Sex Workers
    Ine Vanwesenbeeck
    Archives of Sexual Behavior, 2005, 34 : 627 - 639
  • [6] Occludin gene expression as an early in vitro sign for mild eye irritation assessment
    Meloni, Marisa
    Pauly, Aude
    De Servi, Barbara
    Le Varlet, Beatrice
    Baudouin, Christophe
    TOXICOLOGY IN VITRO, 2010, 24 (01) : 276 - 285
  • [7] Association of the Indoor Environment With Dry Eye Metrics
    Huang, Amy
    Janecki, Julia
    Galor, Anat
    Rock, Sarah
    Menendez, Dhariyat
    Hackam, Abigail S.
    Jeng, Bennie H.
    Kumar, Naresh
    JAMA OPHTHALMOLOGY, 2020, 138 (08) : 867 - 874
  • [8] Eye Irritation Caused by Formaldehyde as an Indoor Air Pollution——A Controlled Human Exposure Experiment
    YANG XU *
    +Department of Public Health
    BiomedicalandEnvironmentalSciences, 2001, (03) : 229 - 236
  • [9] Eye irritation caused by formaldehyde as an indoor air pollution - A controlled human exposure experiment
    Yang, X
    Zhang, YP
    Chen, D
    Chen, WG
    Wang, R
    BIOMEDICAL AND ENVIRONMENTAL SCIENCES, 2001, 14 (03) : 229 - 236
  • [10] NITROGEN DIOXIDE LEVELS IN THE INDOOR ENVIRONMENT OF A HOSPITAL
    Loizidou, M.
    Lagoudi, A.
    Petrakis, M.