Simultaneous measurement for temperature and strain by use of Sagnac interferometer with controlled sensitivity

被引:0
|
作者
Sun, Guoyong [1 ]
Moon, Dae Seung [1 ]
Lin, Aoxiang [1 ]
Han, Won-Taek [1 ]
Chung, Youngjoo [1 ]
机构
[1] Gwangju Inst Sci & Technol, Dept Informat & Commun, Kwangju 500712, South Korea
关键词
Sagnac interferometer; high birefringence fiber; fiber sensors; temperature and strain discrimination;
D O I
10.1117/12.785896
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
We propose a novel approach for resolving temperature and strain variations by use of Sagnac interferometer incorporating two types of high birefringence fibers (HBFs) and a polarization controller. The two types of HBFs are spliced together to act as the sensing head for temperature and strain discrimination. The detected parameters are two wavelength dips over a broad wavelength range in the transmission spectrum of the Sagnac interferometer, whose sensitivity responses to temperature and strain both depend on those of the two HBFs. As a result, the sensitivity responses can be controlled by adjusting the polarization controller adjacent to the sensing head to shift the wavelength dips and then change their degrees of dependence on the two HBFs.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Ultrahigh Sensitivity Sensor for Temperature and Strain Measurement Based on Solc-Sagnac Interferometer
    Liu, Qiang
    Xu, Tian-Shuai
    Zhang, Yu
    Li, Yang
    Wu, Qiang
    Fu, Yongqing
    Wang, Qiao-Yun
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2024, 73 : 1 - 8
  • [2] Simultaneous measurement of strain and temperature with a long-period fiber grating inscribed Sagnac interferometer
    Kang, Juan
    Dong, Xinyong
    Zhao, Chunliu
    Qian, Wenwen
    Li, Mengchao
    OPTICS COMMUNICATIONS, 2011, 284 (08) : 2145 - 2148
  • [3] Sagnac Interferometer Based Digital Shearography for Simultaneous Dual Sensitivity Measurement
    Zhang, Boyang
    Zheng, Xiaowan
    Guo, Bicheng
    Fang, Siyuan
    Sia, Bernard
    Yang, Lianxiang
    OPTICS AND LASERS IN ENGINEERING, 2022, 152
  • [4] A Sagnac Loop Sensor for Simultaneous Strain and Temperature Measurement
    Kang, Juan
    Dong, Xinyong
    Zhao, Chunliu
    Zhao, Youwei
    Li, Mengchao
    21ST INTERNATIONAL CONFERENCE ON OPTICAL FIBER SENSORS, 2011, 7753
  • [5] Simultaneous Measurement of Temperature and Strain Based on Long-Period Fiber Grating and Sagnac Interferometer Spectrum
    Shao Min
    Qiao Xue-guang
    Zhao Xue
    Fu Hai-wei
    Jia Zhen-an
    Feng De-quan
    SPECTROSCOPY AND SPECTRAL ANALYSIS, 2012, 32 (09) : 2318 - 2321
  • [6] Hybrid Sagnac interferometer with high measurement resolution for simultaneous measurement of ambient index and temperature
    Kwon, Oh-Jang
    Han, Young-Geun
    23RD INTERNATIONAL CONFERENCE ON OPTICAL FIBRE SENSORS, 2014, 9157
  • [7] Inner cladding fiber interferometer for the simultaneous measurement of temperature and strain
    Kim, Myoung Jin
    Kim, Young Ho
    Mm, Seok Han
    Mudhana, Gopinath
    Lee, Byeong Ha
    2008 CONFERENCE ON OPTICAL FIBER COMMUNICATION/NATIONAL FIBER OPTIC ENGINEERS CONFERENCE, VOLS 1-8, 2008, : 31 - 33
  • [9] PMF based Sagnac interferometric sensor for simultaneous measurement of strain, temperature, and torsion
    Fu, Jiahui
    Guan, Junneng
    Ding, Shujia
    Chen, Yongjin
    Huang, Peng
    Wei, Zhongchao
    Tan, Chunhua
    Wang, Faqiang
    Meng, Hongyun
    OPTICS COMMUNICATIONS, 2024, 573
  • [10] Fiber-optic simultaneous measurement of strain and temperature using a PM-PCF-based Sagnac interferometer incorporating a pumped EDF
    Kwon, Oh-Jang
    Kim, Hyun-Joo
    Cuh, Suho
    Yoon, Min-Seok
    Park, Sangoh
    Shim, Youngbo
    Jeong, Myung Yung
    Kim, Chang-Seok
    Han, Young-Geun
    FOURTH EUROPEAN WORKSHOP ON OPTICAL FIBRE SENSORS, 2010, 7653