Voltage Regulation of a Stand-Alone Three-Phase SEIG feeding Single-Phase Loads

被引:0
|
作者
Kumari, Stuty [1 ]
Bhuvaneswari, G. [1 ]
机构
[1] IIT Delhi, Dept Elect Engn, New Delhi, India
关键词
self-excited induction generator; voltage regulation; switched capacitor;
D O I
暂无
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
This paper presents a voltage regulation scheme for a Three-phase self-excited induction generator (SEIG) feeding a single-phase load in stand-alone configuration. The proposed scheme uses switching of three-phase capacitor banks using triacs. The switching signals for the triacs at appropriate instants are generated by comparing the actual load voltage with a reference voltage. The simulation study for this scheme has been done in Simulink environment. Both simulation and experimental results have been presented in the paper for an induction machine of 2 hp rating.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] STATCOM-Based Controller for a Three-Phase SEIG Feeding Single-Phase Loads
    Singh, Bhim
    Murthy, S. S.
    Chilipi, Raja Sekhara Reddy
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2014, 29 (02) : 320 - 331
  • [2] A novel excitation scheme for a stand-alone three-phase induction generator supplying single-phase loads
    Chan, TF
    Lai, LL
    IEEE TRANSACTIONS ON ENERGY CONVERSION, 2004, 19 (01) : 136 - 143
  • [3] Stand-Alone Single-Phase Power Generation Employing a Three-Phase Isolated Asynchronous Generator
    Singh, Bhim
    Sharma, Shailendra
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2012, 48 (06) : 2414 - 2423
  • [4] Control of three-phase stand-alone photovoltaic systems with unbalanced loads
    Sanchis, P
    Ursúa, A
    Gubía, E
    López, J
    Marroyo, L
    ISIE 2005: PROCEEDINGS OF THE IEEE INTERNATIONAL SYMPOSIUM ON INDUSTRIAL ELECTRONICS 2005, VOLS 1- 4, 2005, : 633 - 638
  • [5] General steady-state analysis of three-phase selfexcited induction generator feeding three-phase unbalanced load/single-phase load for stand-alone applications
    Murthy, SS
    Singh, B
    Gupta, S
    Gulati, BM
    IEE PROCEEDINGS-GENERATION TRANSMISSION AND DISTRIBUTION, 2003, 150 (01) : 49 - 55
  • [6] A Balancing Method for Three-Phase SEIG Feeding a Single-Phase Load by using Switched Capacitors
    Zine-Eddine, Benhacine Tarek
    Ali, Nesba
    Said, Mekhtoub
    Rachid, Ibtiouen
    PROCEEDINGS 2018 3RD INTERNATIONAL CONFERENCE ON ELECTRICAL SCIENCES AND TECHNOLOGIES IN MAGHREB (CISTEM), 2018, : 822 - 827
  • [7] A new approach for steady state analysis of three-phase SEIG feeding single-phase load
    Benhacine, Tarek Zine Eddine
    Nesba, Ali
    Mekhtoub, Said
    Ibtiouen, Rachid
    COMPEL-THE INTERNATIONAL JOURNAL FOR COMPUTATION AND MATHEMATICS IN ELECTRICAL AND ELECTRONIC ENGINEERING, 2019, 38 (01) : 46 - 67
  • [8] Single-Phase Power Generation Employing VFC for Stand-Alone Three-Phase Doubly Wound Asynchronous Generator
    Sharma, Shailendra Kumar
    Singh, Bhim
    Chandra, Ambrish
    Al-Haddad, Kamal
    IEEE TRANSACTIONS ON INDUSTRY APPLICATIONS, 2015, 51 (06) : 4785 - 4796
  • [9] Hardware Investigation of a New Phase Balancing Topology for Supplying Single-Phase Loads using Three-Phase SEIG
    Chakraborty, Samrat
    Pudur, Rajen
    2022 IEEE SUSTAINABLE POWER AND ENERGY CONFERENCE (ISPEC), 2022,
  • [10] THREE-PHASE STATCOM CONTROLLER USING D-Q FRAME THEORY FOR A THREE-PHASE SEIG FEEDING SINGLE PHASE LOADS
    Ponananthi, V.
    Kumar, B. Rajesh
    2015 2ND INTERNATIONAL CONFERENCE ON ELECTRONICS AND COMMUNICATION SYSTEMS (ICECS), 2015, : 926 - 931