Performance evaluation for a novel optoelectronic device for noninvasive monitoring thrombosis

被引:1
|
作者
Zhao, Ke [1 ]
Pan, Boan [1 ]
Li, Zebing [1 ]
Zhong, Fulin [1 ]
Wang, Pengbo [1 ]
Li, Ting [2 ,3 ]
机构
[1] Univ Elect Sci & Technol China, State Key Lab Elect Thin Films & Integrated Devic, Chengdu, Sichuan, Peoples R China
[2] Chinese Acad Med Sci, Inst Biomed Engn, Tianjin 300192, Peoples R China
[3] Peking Union Med Coll, Tianjin 300192, Peoples R China
关键词
Deep vein thrombosis; Near infrared spectroscopy; Performance evaluation; NEAR-INFRARED SPECTROSCOPY; DEEP-VEIN THROMBOSIS; PULMONARY-EMBOLISM; VENOUS THROMBOSIS; PREVENTION; THERAPY;
D O I
10.1016/j.microrel.2018.03.021
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
Deep vein thrombosis (DVT) is the main type of venous thromboembolism, which is the most common thrombotic disease. In this study, we developed a set of non-invasive thrombosis diagnostic device. A series of experiments were employed to evaluate its performance including stability, robustness, sensitivity and test on human. The results showed that near infrared spectroscopy (NIBS) could reliably monitor thrombosis for DVT patients. With its noninvasive, rapid, continuous, and real-time features, NIBS can detect human hemodynamic parameters and show advantages in DVT diagnosis.
引用
收藏
页码:134 / 139
页数:6
相关论文
共 50 条
  • [1] Performance Evaluation of a Noninvasive Hemoglobin Monitoring Device
    Gayat, Etienne
    Bodin, Antoine
    Sportiello, Caroline
    Boisson, Mireille
    Dreyfus, Jean-Francois
    Mathieu, Emmanuel
    Fischler, Marc
    ANNALS OF EMERGENCY MEDICINE, 2011, 57 (04) : 330 - 333
  • [2] Evaluation of a noninvasive hemoglobin and hematocrit monitoring device
    D Dvir
    D Geva
    O Amir
    I Fine
    E Monashkin
    G Fostick
    E Segal
    Critical Care, 9 (Suppl 1):
  • [3] Evaluation of a novel noninvasive ICP monitoring device in patients undergoing invasive ICP monitoring: preliminary results
    Ganslandt, Oliver
    Mourtzoukos, Stylianos
    Stadlbauer, Andreas
    Sommer, Bjoern
    Rammensee, Rudolf
    JOURNAL OF NEUROSURGERY, 2018, 128 (06) : 1653 - 1660
  • [4] NONINVASIVE MONITORING OF RESPIRATORY VOLUME - EXPERIMENTAL EVALUATION OF A BREATH MONITORING DEVICE
    AMIN, HM
    CIGADA, M
    FORDYCE, WE
    CAMPORESI, EM
    ANAESTHESIA, 1993, 48 (07) : 608 - 610
  • [5] Noninvasive optoelectronic monitoring of the living tissues vitality
    Cysewska-Sobusiak, A
    ROMOCO'02: PROCEEDINGS OF THE THIRD INTERNATIONAL WORKSHOP ON ROBOT MOTION AND CONTROL, 2002, : 13 - 19
  • [6] Evaluation of a noninvasive blood glucose monitoring device for critically ill patients
    O Amir
    D Dvir
    B Grunberg
    J Cohen
    E Gabis
    P Singer
    Critical Care, 12 (Suppl 2):
  • [7] EVALUATION OF A NEW NONINVASIVE SEMIAUTOMATIC BLOOD-PRESSURE MONITORING DEVICE
    FUKUOKA, M
    YAMORI, Y
    UENO, T
    KODAMA, S
    PARATI, G
    POMIDOSSI, G
    MANCIA, G
    ZANCHETTI, A
    CLINICAL AND EXPERIMENTAL HYPERTENSION PART A-THEORY AND PRACTICE, 1987, 9 (01) : 141 - 152
  • [8] Evaluation of a noninvasive blood glucose monitoring device for critically ill patients
    A Kononenko
    D Dvir
    B Grunberg
    J Cohen
    E Gabis
    P Singer
    Critical Care, 10 (Suppl 1):
  • [9] Performance evaluation of optoelectronic processing systems based on device area resources
    Tanida, J
    OPTICS COMMUNICATIONS, 1999, 171 (1-3) : 45 - 51
  • [10] GlucoScan: Noninvasive Glucose Monitoring Device
    Kendell, Claire
    Watson, Amanda
    Lee, Insup
    Weimer, James
    2022 IEEE/ACM CONFERENCE ON CONNECTED HEALTH: APPLICATIONS, SYSTEMS AND ENGINEERING TECHNOLOGIES (CHASE 2022), 2022, : 158 - 159