Near infra-red fluorescence-guidance for percutaneous sclerotherapy of thoracic duct leak

被引:1
|
作者
Brito, Catarina [1 ,2 ]
Vilela, Pedro [3 ,4 ,5 ,6 ,7 ,8 ]
机构
[1] Hosp Beatriz Angelo, Neuroradiol Dept, Ave Carlos Teixeira 3, P-2674514 Lisbon, Portugal
[2] UCL, London, England
[3] Hosp Beatriz Angelo, Lisbon, Portugal
[4] Hosp Garcia Orta, Lisbon, Portugal
[5] Hosp Luz, Lisbon, Portugal
[6] Inst Council European Soc Neuroradiol ESNR, Tarragona, Spain
[7] Portuguese Neuroradiol Soc SPNR, Lisbon, Portugal
[8] Spanish Neuroradiol Soc SENR, Badajoz, Spain
关键词
Thoracic duct (TD) leak; Chyle leak; Near infra-red fluorescence (NIR); Percutaneous sclerotherapy; Doxycycline; CERVICAL CHYLOUS LYMPHOCELE; INTERVENTION;
D O I
10.1016/j.amjoto.2020.102463
中图分类号
R76 [耳鼻咽喉科学];
学科分类号
100213 ;
摘要
Treatment of thoracic duct leaks can be very challenging. Intractable chlye leaks may require image-guided methods to increase the likelihood of treatment success. Near infra-red fluorescence is an easy-to-use non-ionizing imaging method that has been described to detect thoracic duct leaks in open surgery or thoracoscopic interventions, yet no application to percutaneous sclerotherapy has been described. The authors suggest near infra-red fluorescence as a feasible and useful tool to guide percutaneous sclerotherapy.
引用
收藏
页数:4
相关论文
共 50 条
  • [1] Near infra-red fluorescence identification of the thoracic duct to prevent chyle leaks during oesophagectomy
    Thomas G. Barnes
    Thomas MacGregor
    Bruno Sgromo
    Nicholas D. Maynard
    Richard S. Gillies
    [J]. Surgical Endoscopy, 2022, 36 : 5319 - 5325
  • [2] Near infra-red fluorescence identification of the thoracic duct to prevent chyle leaks during oesophagectomy
    Barnes, Thomas G.
    MacGregor, Thomas
    Sgromo, Bruno
    Maynard, Nicholas D.
    Gillies, Richard S.
    [J]. SURGICAL ENDOSCOPY AND OTHER INTERVENTIONAL TECHNIQUES, 2022, 36 (07): : 5319 - 5325
  • [3] Near infra-red spectroscopy
    Fearn, SJ
    Mead, GE
    Picton, AJ
    Mortimer, AJ
    McCollum, CN
    [J]. ANAESTHESIA, 1996, 51 (08) : 800 - 800
  • [4] NEAR INFRA-RED ONLINE ANALYSIS
    SCOTT, M
    [J]. CONTROL AND INSTRUMENTATION, 1991, 23 (03): : 40 - 43
  • [5] A REVIEW OF NEAR INFRA-RED SPECTROSCOPY
    Donnelly, Peter
    Fine-Goulden, Miriam
    [J]. ARCHIVES OF DISEASE IN CHILDHOOD, 2019, 104 : A180 - A181
  • [6] Applications of near infra-red spectrophotometry
    Stearns, E
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1943, 33 (01) : 27 - 30
  • [7] NEAR INFRA-RED TRANSMITTING FILTERS
    BLOUT, ER
    LAND, EH
    AMON, WF
    THOMAS, A
    SHEPHERD, RG
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1946, 36 (06) : 361 - 361
  • [8] NEAR INFRA-RED TRANSMITTING FILTERS
    BLOUT, ER
    AMON, WF
    SHEPHERD, RG
    THOMAS, A
    WEST, CD
    LAND, EH
    [J]. JOURNAL OF THE OPTICAL SOCIETY OF AMERICA, 1946, 36 (08) : 460 - 464
  • [9] ROTATABLE POLARIZERS FOR NEAR INFRA-RED
    LAMBERT, RM
    ENOCH, RD
    [J]. JOURNAL OF PHYSICS E-SCIENTIFIC INSTRUMENTS, 1969, 2 (09): : 799 - &
  • [10] DIFFERENCE SPECTROSCOPY IN THE NEAR INFRA-RED
    WILLIS, HA
    MILLER, RGJ
    [J]. SPECTROCHIMICA ACTA, 1959, 14 (JAN): : 119 - 126