Increased healthcare utilization associated with complete atrioventricular block in pacemaker patients

被引:1
|
作者
Mittal, Suneet [1 ]
Musat, Dan L. [1 ]
Hoskins, Michael H. [2 ]
Prillinger, Julie B. [3 ]
Roberts, Gregory J. [3 ]
Nabutovsky, Yelena [3 ]
Merchant, Faisal M. [2 ]
机构
[1] Valley Hlth Syst, Snyder Ctr Comprehens Atrial Fibrillat, Ridgewood, NJ 07450 USA
[2] Emory Univ, Sch Med, Atlanta, GA USA
[3] Abbott, Sylmar, CA USA
关键词
Pacemakers; Heart failure; Atrioventricular block; Right ventricular pacing; Healthcare utilization; PACING-INDUCED CARDIOMYOPATHY; VENTRICULAR-FUNCTION; PREDICTORS; ICD-9-CM; THERAPY;
D O I
10.1007/s10840-018-0336-0
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
The purpose of the current study is to characterize and quantify the impact of complete atrioventricular block (cAVB) on heart failure hospitalization (HFH) and healthcare utilization in pacemaker (PM) patients. Patients 18 years implanted with a dual-chamber PM from April 2008 to March 2014 were selected from the MarketScanA (R) Commercial and Medicare Supplemental claims databases. Patients with 1-year continuous MarketScan enrollment prior to and post-implant, and those with prior HF diagnosis were excluded. Patients were dichotomized into those with cAVB, defined as a 3rd degree AVB diagnosis or AV node ablation in the year prior to PM implant, versus those without any AVB (noAVB). Post-implant HFH and associated costs were compared based on inpatient claims. The study cohort included 21,202 patients, of which 14,208 had no AVB and 6994 had cAVB, followed for 2.39 and 2.27 years, respectively. Patients with cAVB were associated with a significantly increased risk of cumulative HFH (HR 1.59 [95% CI 1.35-1.86] p < 0.001) and significantly higher costs ($636 [609-697] vs $369 [353-405] per pt-year, p < 0.001) compared to those with no AVB. Among dual-chamber PM patients without prior HF, cAVB is associated with a significantly increased risk of HFH and greater HF-related healthcare utilization. Identifying patients at high risk for HF in the setting of RV pacing, and potentially earlier use of biventricular or selective conduction system pacing, may reduce HF-related healthcare utilization.
引用
收藏
页码:221 / 228
页数:8
相关论文
共 50 条
  • [1] Increased healthcare utilization associated with complete atrioventricular block in pacemaker patients
    Suneet Mittal
    Dan L. Musat
    Michael H. Hoskins
    Julie B. Prillinger
    Gregory J. Roberts
    Yelena Nabutovsky
    Faisal M. Merchant
    [J]. Journal of Interventional Cardiac Electrophysiology, 2018, 51 : 221 - 228
  • [2] Leadless Pacemaker Implantation in Patients With Paroxysmal Complete Atrioventricular Block
    Mendoza, Ivan
    Penalver, Jorge
    Aranguibel, Ninoska N.
    Jose, Chamorro
    Zambrano, Juan P.
    Mendoza, Ivan
    [J]. CIRCULATION, 2020, 142
  • [3] Pacemaker therapy in isolated congenital complete atrioventricular block
    Breur, JMPJ
    Ten Cate, FEAU
    Kapusta, L
    Cohen, MI
    Crosson, JE
    Boramanand, N
    Lubbers, LJ
    Friedman, AH
    Brenner, JI
    Vetter, VL
    Sreeram, N
    Meijboom, EJ
    [J]. PACE-PACING AND CLINICAL ELECTROPHYSIOLOGY, 2002, 25 (12): : 1685 - 1691
  • [4] Pacemaker therapy in isolated congenital complete atrioventricular block
    Breur, JMPJ
    Ten Cate, FEAU
    Kapusta, L
    Cohen, MI
    Crosson, JE
    Bidlingmaier, N
    Lubbers, LJ
    Friedman, AH
    Brenner, JI
    Vetter, VL
    Sreeram, N
    Meijboom, EJ
    [J]. CIRCULATION, 2000, 102 (18) : 821 - 821
  • [5] IMPLANTATION OF A PROGRAMMABLE ATRIOVENTRICULAR PACEMAKER IN A DONKEY WITH COMPLETE ATRIOVENTRICULAR-BLOCK AND SYNCOPE
    PIBAROT, P
    VRINS, A
    SALMON, Y
    DIFRUSCIA, R
    [J]. EQUINE VETERINARY JOURNAL, 1993, 25 (03) : 248 - 251
  • [6] Tachycardia after pacemaker implantation in a patient with complete atrioventricular block
    Duray, Gabor Z.
    Israel, Carsten W.
    Wegener, Florian T.
    Hohnloser, Stefan H.
    [J]. EUROPACE, 2007, 9 (10): : 900 - 903
  • [7] COMPLETE ATRIOVENTRICULAR-BLOCK IN PATIENTS WITH ATRIOVENTRICULAR DISCORDANCE
    HUHTA, JC
    MALONEY, JD
    RITTER, DG
    ILSTRUP, DM
    FELDT, RH
    [J]. CIRCULATION, 1983, 67 (06) : 1374 - 1377
  • [8] EFFECT OF INTRACARDIAL PACEMAKER THERAPY ON CEREBRAL BLOOD FLOW AND ELECTROENCEPHALOGRAM IN PATIENTS WITH COMPLETE ATRIOVENTRICULAR BLOCK
    SULG, IA
    CRONQVIST, S
    SCHULLER, H
    INGVAR, DH
    [J]. CIRCULATION, 1969, 39 (04) : 487 - +
  • [9] Intermittently audible the "third heart sound" as a sign of complete atrioventricular block in patients with a VVI pacemaker
    Iga, K
    Konishi, T
    [J]. INTERNATIONAL JOURNAL OF CARDIOLOGY, 1999, 71 (02) : 135 - 139
  • [10] Myocardial scintigraphy after pacemaker implantation for congenital complete atrioventricular block
    Hisashi Takasugi
    Ken Watanabe
    Yasuo Ono
    Heima Sakaguchi
    Noriko Motoki
    Yoko Yoshida
    Shigeyuki Echigo
    Kazuki Fukuchi
    Yoshio Ishida
    [J]. European Journal of Pediatrics, 2008, 167 : 183 - 188