Racial variation in optic nerve head parameters quantified in healthy newborns by handheld spectral domain optical coherence tomography

被引:20
|
作者
Allingham, Michael J. [1 ]
Cabrera, Michelle T. [2 ]
O'Connell, Rachelle V. [1 ]
Maldonado, Ramiro S. [1 ]
Du Tran-Viet [1 ]
Toth, Cynthia A. [1 ,3 ]
Freedman, Sharon F. [1 ,4 ]
El-Dairi, Mays A. [1 ]
机构
[1] Duke Eye Ctr, Dept Ophthalmol, Durham, NC 27710 USA
[2] Kittner Eye Ctr, Dept Ophthalmol, Chapel Hill, NC USA
[3] Pratt Sch Engn, Dept Biomed Engn, Durham, NC USA
[4] Duke Univ, Dept Pediat, Sch Med, Durham, NC 27706 USA
来源
JOURNAL OF AAPOS | 2013年 / 17卷 / 05期
基金
美国国家卫生研究院;
关键词
DISK SIZE; BIRTH-WEIGHT; POSTNATAL-GROWTH; CHILDREN BORN; HUMAN FOVEA; AGE; MORPHOLOGY; THICKNESS; PRETERM; INFANT;
D O I
10.1016/j.jaapos.2013.06.014
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
PURPOSE To characterize optic nerve head (ONH) morphology and parameters, including vertical disk diameter, vertical cup diameter, and vertical cup/disk ratio in healthy, full-term newborns using a handheld spectral domain optical coherence tomography (SD-OCT) device. METHODS In this prospective observational case series, healthy white, black, and Hispanic full-term newborns delivered at the Duke Birthing Center between August 2010 and May 2011 underwent dilated fundus examination and SD-OCT imaging of the optic nerve in each eye. OCT parameters were calculated and compared for each group of infants. RESULTS A total of 58 consecutive newborns of white (n = 22), black (n = 15) and Hispanic (n = 21) ethnicity were included. Mean vertical disk diameter in white, black, and Hispanic newborns was 1.29 +/- 0.15 mm (standard deviation), 1.38 +/- 0.14 mm, and 1.38 +/- 0.14 mm, respectively (white versus Hispanic, P = 0.02; white versus black, P = 0.07). Mean vertical cup diameter in white, black, and Hispanic newborns was 0.44 +/- 0.15 mm, 0.56 +/- 0.23 nun, and 0.46 +/- 0.30 mm, respectively (white versus black, P = 0.03). Mean vertical cup/disk ratio was 0.34 +/- 0.10 for white, 0.40 +/- 0.17 for black, and 0.33 +/- 0.20 for Hispanic newborns (P = 0.07 for white versus black). CONCLUSIONS Handheld SD-OCT is an effective means of imaging the ONH in newborns. Racial differences in cup/disk ratio are present at birth. These data may serve as the beginning of a normative dataset for characterizing development of the ONH as well as for comparison to the neonatal ONH in disease states.
引用
收藏
页码:501 / 506
页数:6
相关论文
共 50 条
  • [1] Optic Nerve Head Development in Healthy Infants and Children Using Handheld Spectral-Domain Optical Coherence Tomography
    Patel, Aarti
    Purohit, Ravi
    Lee, Helena
    Sheth, Viral
    Maconachie, Gail
    Papageorgiou, Eleni
    McLean, Rebecca J.
    Gottlob, Irene
    Proudlock, Frank A.
    OPHTHALMOLOGY, 2016, 123 (10) : 2147 - 2157
  • [2] Optic Nerve Head Parameters of Healthy Children as Measured by Optical Coherence Tomography
    Lee, Jung Min
    Hwang, Young Hoon
    JOURNAL OF THE KOREAN OPHTHALMOLOGICAL SOCIETY, 2020, 61 (04): : 376 - 384
  • [3] HEMORRHAGIC COMPLICATIONS OF OPTIC NERVE HEAD DRUSEN ON SPECTRAL DOMAIN OPTICAL COHERENCE TOMOGRAPHY
    Lee, Kyoung Min
    Hwang, Jeong-Min
    Woo, Se Joon
    RETINA-THE JOURNAL OF RETINAL AND VITREOUS DISEASES, 2014, 34 (06): : 1142 - 1148
  • [4] Imaging of Optic Nerve Head Drusen Improvements With Spectral Domain Optical Coherence Tomography
    Yi, Kayoung
    Mujat, Mircea
    Sun, Wei
    Burnes, Daina
    Latina, Mark A.
    Lin, Derrick T.
    Deschler, Daniel G.
    Rubin, Peter A. D.
    Park, Boris Hyle
    de Boer, Johannes F.
    Chen, Teresa C.
    JOURNAL OF GLAUCOMA, 2009, 18 (05) : 373 - 378
  • [5] Do biometric parameters improve the quality of optic nerve head measurements with spectral domain optical coherence tomography?
    Elksne, E.
    Stingl, J., V
    Schuster, A. K.
    Wagner, F. M.
    Hoffmann, E. M.
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [6] Correlating morphometric parameters of the porcine optic nerve head in spectral domain optical coherence tomography with histological sections
    Fatehee, Naeem
    Yu, Paula K.
    Morgan, William H.
    Cringle, Stephen J.
    Yu, Dao-Yi
    BRITISH JOURNAL OF OPHTHALMOLOGY, 2011, 95 (04) : 585 - 589
  • [7] Do biometric parameters improve the quality of optic nerve head measurements with spectral domain optical coherence tomography?
    E. Elksne
    J. V. Stingl
    A. K. Schuster
    F. M. Wagner
    E. M. Hoffmann
    BMC Ophthalmology, 22
  • [8] Optic Nerve Parameters in Obese Children as Measured by Spectral Domain Optical Coherence Tomography
    Koca, Semra
    Keskin, Meliksah
    Saricaoglu, M. Sinan
    Koca, Serkan Bilge
    Duru, Necati
    Hamurcu, Mualla Sahin
    Muratoglu, Nursel Sahin
    Aycan, Zehra
    SEMINARS IN OPHTHALMOLOGY, 2017, 32 (06) : 743 - 747
  • [9] Effect of head tilt on repeatability of optic nerve head parameters using Cirrus spectral-domain optical coherence tomography
    Lilian Hui Li Koh
    Muhammad Amir Ismail
    Sae Cheong Yap
    Elizabeth Poh Ying Wong
    Leonard Wei Leon Yip
    International Journal of Ophthalmology, 2016, (08) : 1170 - 1175
  • [10] Effect of head tilt on repeatability of optic nerve head parameters using Cirrus spectral-domain optical coherence tomography
    Koh, Lilian Hui Li
    Ismail, Muhammad Amir
    Yap, Sae Cheong
    Wong, Elizabeth Poh Ying
    Yip, Leonard Wei Leon
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2016, 9 (08) : 1170 - 1175