Speech dynamic range and its effect on cochlear implant performance

被引:121
|
作者
Zeng, FG
Grant, G
Niparko, J
Galvin, J
Shannon, R
Opie, J
Segel, P
机构
[1] Univ Calif Irvine, Dept Otolaryngol, Irvine, CA 92697 USA
[2] Univ Calif Irvine, Dept Biomed Engn, Irvine, CA 92697 USA
[3] Univ Calif Irvine, Dept Cognit Sci, Irvine, CA 92697 USA
[4] Johns Hopkins Univ, Dept Otolaryngol, Baltimore, MD 21287 USA
[5] House Ear Res Inst, Los Angeles, CA 90057 USA
[6] Adv Bion Corp, Sylmar, CA 91342 USA
来源
关键词
D O I
10.1121/1.1423926
中图分类号
O42 [声学];
学科分类号
070206 ; 082403 ;
摘要
This study examines optimal conversions of speech sounds to audible electric currents in cochlear-implant listeners. The speech dynamic range was measured for 20 consonants and 12 vowels spoken by five female and five male talkers. Even when the maximal root-mean-square (rms) level was normalized for all phoneme tokens, both broadband and narrow-band acoustic analyses showed an approximately 50-dB distribution of speech envelope levels. Phoneme recognition was also obtained in ten CLARION implant users as a function of the input dynamic range from 10 to 80 dB in 10-dB steps. Acoustic amplitudes within a specified input dynamic range were, logarithmically mapped into the 10-20-dB range of electric stimulation typically found in cochlear-implant users. Consistent with acoustic data, the perceptual data showed that a 50-60-dB input dynamic range produced optimal speech recognition in these implant users. The present results indicate that speech dynamic range is much greater than the commonly assumed 30-dB range. A new amplitude mapping strategy, based on envelope distribution differences between consonants and vowels, is proposed to optimize acoustic-to-electric mapping of speech sounds. This new strategy will use a logarithmic map for low-frequency channels and a more compressive map for high-frequency channels, and may improve overall speech recognition for cochlear-implant users. (C) 2002 Acoustical Society of America.
引用
收藏
页码:377 / 386
页数:10
相关论文
共 50 条
  • [1] Improvement of cochlear implant performance: changes in dynamic range
    Khater A.
    El Shennaway A.
    Anany A.
    [J]. The Egyptian Journal of Otolaryngology, 2015, 31 (1) : 36 - 41
  • [2] The Effect of Cochlear Coverage on Auditory and Speech Performance in Cochlear Implant Patients
    Doubi, Aseel
    Almuhawas, Fida
    Alzhrani, Farid
    Doubi, Motaz
    Aljutaili, Hamad
    Hagr, Abdulrahman
    [J]. OTOLOGY & NEUROTOLOGY, 2019, 40 (05) : 602 - 607
  • [3] Optimizing cochlear implant speech performance
    Skinner, MW
    [J]. ANNALS OF OTOLOGY RHINOLOGY AND LARYNGOLOGY, 2003, 112 (09): : 4 - 13
  • [4] Effect of dynamic range and location on temporal pitch perception of cochlear implant users
    Penninger, R. T.
    Limb, C. J.
    Dhooge, I
    Buechner, A.
    [J]. BIOMEDICAL ENGINEERING-BIOMEDIZINISCHE TECHNIK, 2014, 59 : S753 - +
  • [5] Cochlear implant: More hearing better speech performance
    Alhabib, Salman F.
    Abdelsamad, Yassin
    Badghaish, Reem S.
    Alzhrani, Farid
    Hagr, Abdulrahman
    Almuhawas, Fida
    [J]. INTERNATIONAL JOURNAL OF PEDIATRIC OTORHINOLARYNGOLOGY, 2021, 150
  • [6] Speech Performance and Training Effects in the Cochlear Implant Elderly
    Schumann, Annette
    Hast, Anne
    Hoppe, Ulrich
    [J]. AUDIOLOGY AND NEURO-OTOLOGY, 2014, 19 : 45 - 48
  • [7] PROGNOSTICATING SPEECH PERFORMANCE IN MULTICHANNEL COCHLEAR IMPLANT PATIENTS
    PARKIN, JL
    STEWART, BE
    DANKOWSKI, K
    HAAS, LJ
    [J]. OTOLARYNGOLOGY-HEAD AND NECK SURGERY, 1989, 101 (03) : 314 - 319
  • [8] Performance of patients using different cochlear implant systems: Effects of input dynamic range
    Spahr, Anthony J.
    Dorman, Michael F.
    Loiselle, Louise H.
    [J]. EAR AND HEARING, 2007, 28 (02): : 260 - 275
  • [9] The effect of reduced dynamic range on speech understanding: Implications for patients with cochlear implants
    Loizou, PC
    Dorman, M
    Fitzke, J
    [J]. EAR AND HEARING, 2000, 21 (01): : 25 - 31
  • [10] Cochlear function tests in estimation of speech dynamic range
    Han, Jung Ju
    Park, So Young
    Park, Shi Nae
    Na, Mi Sun
    Lee, Philip
    Han, Jae Sang
    [J]. ACTA OTO-LARYNGOLOGICA, 2016, 136 (10) : 1041 - 1045