Design and kinematics in total knee arthroplasty

被引:50
|
作者
Digennaro, Vitantonio [1 ]
Zambianchi, Francesco [1 ]
Marcovigi, Andrea [1 ]
Mugnai, Raffaele [1 ]
Fiacchi, Francesco [1 ]
Catani, Fabio [1 ]
机构
[1] Univ Modena & Reggio Emilia, Azienda Osped Univ Policlin Modena, Dept Orthopaed Surg, Modena, Italy
关键词
TKA design; Kinematics; Fluoroscopy; Clinical result; FLUOROSCOPIC ANALYSIS; ROTATION; FLEXION; REPLACEMENTS; AXIS;
D O I
10.1007/s00264-013-2245-2
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Purpose Posterior stabilised (PS) total knee arthroplasty (TKA) design development that focused on restoring normal knee kinematics was followed by the introduction of reason-guided motion designs. Although all PS fixed-bearing knee designs were thought to have similar kinematics, reports show they have differing incidences and magnitudes of posterior femoral rollback and axial rotation. In this retrospective comparative study between two guided-motion total knee systems, we hypothesised that kinematic pattern has an influence on clinical and functional outcomes. This study represents the continuation of a previously reported clinical and kinematics analysis. We retrospectively reviewed 347 patients treated with two different TKA designs: Scorpio NRG (Stryker Orthopedics) and Journey Bi-Cruciate Stabilised (BCS) knee system (Smith & Nephew). Two hundred and eighty-one patients were assessed clinically. Patients were divided into groups according to implanted TKA. Clinical evaluation with the Knee Injury and Osteoarthritis Outcome Score (KOOS) questionnaire was performed. Fifteen Scorpio NRG and 16 Journey BCS patients underwent video fluoroscopy during stair climbing, chair rising/sitting and step up/down at six months of follow-up. At an average 29 months of clinical follow-up, patients with Journey BCS TKAs reported better clinical results. Stiffness was more frequently reported in the Journey group (5.2 % vs 1.2 %), whereas anterior knee pain was observed in the Scorpio NRG group (1.9 %) only. Both prosthetic models reported different posterior translation of the medial and lateral contact points (CP) in all analysed motor tasks during knee flexion (BCS 10-18 mm; NRG Scorpio 2-3 mm). Both designs produced progressive external rotation of the femoral component relative to the tibia during flexion. Journey BCS showed statistically significant better KOOS results. The higher posterior femoral rollback observed in the kinematic assessment of this design, associated with a better patellofemoral design, may be the reason for better clinical outcome. The reported cases of stiffness and anterolateral joint pain could be attributed to excessive medial and lateral tibiofemoral posterior translation. The NRG group demonstrated good axial rotation, but this was not coupled with physiological kinematic patterns. Patellofemoral pain can be explained by a less friendly femoral-groove design. TKA clinical-functional outcome and complications were highly influenced by the bearing geometry and kinematic pattern of prosthetic designs.
引用
收藏
页码:227 / 233
页数:7
相关论文
共 50 条
  • [1] Design and kinematics in total knee arthroplasty
    Vitantonio Digennaro
    Francesco Zambianchi
    Andrea Marcovigi
    Raffaele Mugnai
    Francesco Fiacchi
    Fabio Catani
    [J]. International Orthopaedics, 2014, 38 : 227 - 233
  • [2] Total Knee Arthroplasty Kinematics
    Angerame, Marc R.
    Holst, David C.
    Jennings, Jason M.
    Komistek, Richard D.
    Dennis, Douglas A.
    [J]. JOURNAL OF ARTHROPLASTY, 2019, 34 (10): : 2502 - 2510
  • [3] Kinematics of the stiff total knee arthroplasty
    Pereira, Gavin C.
    Walsh, Michael
    Wasserman, Bradley
    Banks, Scott
    Jaffe, William L.
    Di Cesare, Paul E.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (06): : 894 - 901
  • [4] Changes in knee kinematics following total knee arthroplasty
    Shandiz, Mohsen Akbari
    Boulos, Paul
    Saevarsson, Stefan Karl
    Yoo, Sam
    Miller, Stephen
    Anglin, Carolyn
    [J]. PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART H-JOURNAL OF ENGINEERING IN MEDICINE, 2016, 230 (04) : 265 - 278
  • [5] Preoperative knee deformity and kinematics impact postoperative knee kinematics in total knee arthroplasty
    Seito, Naoki
    Onodera, Tomohiro
    Kasahara, Yasuhiko
    Kondo, Eiji
    Iwasaki, Norimasa
    Majima, Tokifumi
    [J]. KNEE, 2017, 24 (06): : 1462 - 1468
  • [6] In vivo determination of total knee arthroplasty kinematics
    Komistek, Richard D.
    Mahfouz, Mohamed R.
    Bertin, Kim C.
    Rosenberg, Aaron
    Kennedy, William
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 41 - 50
  • [7] Kinematics of the patellofemoral joint in total knee arthroplasty
    Stiehl, JB
    Komistek, RD
    Dennis, DA
    Keblish, PA
    [J]. JOURNAL OF ARTHROPLASTY, 2001, 16 (06): : 706 - 714
  • [8] Passive knee kinematics before and after total knee arthroplasty
    Mihalko, William M.
    Ali, Mounawar
    Phillips, Matthew J.
    Bayers-Thering, Mary
    Krackow, Kenneth A.
    [J]. JOURNAL OF ARTHROPLASTY, 2008, 23 (01): : 57 - 60
  • [9] Polyethylene damage and knee kinematics after total knee arthroplasty
    Harman, MK
    Banks, SA
    Hodge, WA
    [J]. CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 2001, (392) : 383 - 393
  • [10] Changes in total knee arthroplasty design affect in-vivo kinematics in a redesigned total knee system: A fluoroscopy study
    Zambianchi, Francesco
    Fiacchi, Francesco
    Lombari, Vincenzo
    Venturelli, Luca
    Marcovigi, Andrea
    Giorgini, Andrea
    Catani, Fabio
    [J]. CLINICAL BIOMECHANICS, 2018, 54 : 92 - 102