The two-year outcome of the I-Stop TOMSTm transobturator sling in the treatment of male stress urinary incontinence in a single centre and prediction of outcome

被引:14
|
作者
Drai, J. [1 ]
Caremel, R. [1 ]
Riou, J. [2 ]
Grise, P. [1 ]
机构
[1] Univ Rouen, Hosp Charles Nicolle, Dept Urol, F-76031 Rouen, France
[2] Univ Hosp Bicetre Univ Hosp, Biostat Unit, F-94275 Le Kremlin Bicetre, France
来源
PROGRES EN UROLOGIE | 2013年 / 23卷 / 17期
关键词
Male urinary incontinence; Male sling; Transobturator sling; Prostatectomy; POSTPROSTATECTOMY INCONTINENCE; SPHINCTER; PROSTATECTOMY; EXPERIENCE; CONTINENCE;
D O I
10.1016/j.purol.2013.08.308
中图分类号
R5 [内科学]; R69 [泌尿科学(泌尿生殖系疾病)];
学科分类号
1002 ; 100201 ;
摘要
Purpose. - The aim of this study was to present the results of the 2 year outcome of I-Stop TOMSTm transobturator sling for post-prostatectomy (UIPP) minor to moderate male urinary incontinence treatment. Materials and methods. - A prospective, single center study, including 26 patients with minor to moderate IUPP and operated on using a suburethral sling (MS) TOMSTm (four arms) was performed. UIPP assessment was made preoperatively and 1 year postoperatively, using validated questionnaires (SF36 and ICIQ), number of pads daily, and the 24 hours Pad-test (LPT). Telephone follow-up evaluation was performed in 21 patients over a 2 years period following surgery. Results. - Radical prostatectomy was performed 48.4 months earlier and average patient age was 67.3 years. Preoperatively, the mean number of pads used daily was 2.3 with an average weight loss of 207.1 grams at LPT. At 1 year, ICIQ and SF36 scores significantly improved. Weight loss in the LPT as well as the number of pads significantly decreased (P<0.05). At 1 year, 13 patients were cured, 12 were improved, one reached improvement criteria, and 96.2% using a pad daily maximum. With more than a 2 year follow-up, 10/21 patients were dry, nine improved and two failed, and 90.5% using 0 to 1 pad per day. Conclusions. - The transobturator TOMSTm male sling is a simple and well-tolerated procedure permitting a significant improvement of UIPP, with 50% of patients achieving complete continence at 1 year postoperatively, these good results continued beyond 2 years. Level of evidence. - 4. (C) 2013 Elsevier Masson SAS. All rights reserved.
引用
收藏
页码:1494 / 1499
页数:6
相关论文
共 50 条
  • [1] Postoperative male stress urinary incontinence: Outcomes of treatment by I-STOP TOMS® transobturator sling
    Ej-Jennane, A.
    Mouracade, P.
    Lang, H.
    Jacqmin, D.
    Saussine, C.
    PROGRES EN UROLOGIE, 2014, 24 (02): : 127 - 131
  • [2] TWO YEAR OUTCOME OF THE TRANSOBTURATOR RETROLUMINAL REPOSITIONING SLING IN THE TREATMENT OF MALE STRESS URINARY INCONTINENCE
    Rehder, P.
    Pichler, R.
    Schachtner, L.
    Kerschbaumer, A.
    Glodny, B.
    EUROPEAN UROLOGY SUPPLEMENTS, 2011, 10 (02) : 309 - 309
  • [3] The 1 year outcome of the transobturator retroluminal repositioning sling in the treatment of male stress urinary incontinence
    Rehder, Peter
    Mitterberger, Michael J.
    Pichler, Renate
    Kerschbaumer, Andrea
    Glodny, Bernhard
    BJU INTERNATIONAL, 2010, 106 (11) : 1668 - 1671
  • [4] OUTCOME OF THE TRANSOBTURATOR RETROLUMINAL REPOSITIONING SLING IN THE TREATMENT OF MALE STRESS URINARY INCONTINENCE
    Redher, Peter
    Pichler, Renate
    Mitterberger, Michael
    Kerschbaumer, Andrea
    JOURNAL OF UROLOGY, 2010, 183 (04): : E427 - E427
  • [5] The 1 year outcome of the transobturator retroluminal repositioning sling in the treatment of male stress urinary incontinence EDITORIAL COMMENT
    Cornu, Jean-Nicolas
    Haab, Francois
    BJU INTERNATIONAL, 2010, 106 (11) : 1671 - 1672
  • [6] THE 1-YEAR OUTCOME OF THE TRANSOBTURATOR RETROLUMINAL REPOSITIONING SLING IN THE TREATMENT OF MALE STRESS URINARY INCONTINENCE REPLY
    Rehder, Peter
    Glodny, Bernhard
    BJU INTERNATIONAL, 2010, 106 (07) : 1091 - 1092
  • [7] The 1 Year Outcome of the Transobturator Retroluminal Repositioning Sling in the Treatment of Male Stress Urinary Incontinence Editorial Comment
    Morey, Allen F.
    JOURNAL OF UROLOGY, 2011, 186 (02): : 584 - 584
  • [8] Seven-year follow-up of 331 I-Stop transobturator sling cases in female urinary incontinence treatment
    Lienhart, J.
    Vautherin, R.
    Grisard-Anaf, M.
    Frobert, J. -L.
    PROGRES EN UROLOGIE, 2014, 24 (12): : 750 - 756
  • [9] I-Stop TOMS Transobturator Male Sling, a Minimally Invasive Treatment for Postprostatectomy Incontinence: Continence Improvement and Tolerability
    Grise, Philippe
    Vautherin, Renaud
    Njinou-Ngninkeu, Bertin
    Bochereau, Ghislain
    Lienhart, Jean
    Saussine, Christian
    UROLOGY, 2012, 79 (02) : 458 - 463
  • [10] Urinary retention post Transobturator sling placement as a prognostic factor for continence outcome in the treatment of male stress incontinence
    Chung, A.
    Zuckerman, J.
    Suarez, O.
    Virasoro, R.
    Tonkin, J.
    Delong, J.
    McCammon, K.
    BJU INTERNATIONAL, 2018, 121 : 58 - 58