Reliability of dual inclinometer for lumbar range of motion using two different Landmarking techniques

被引:1
|
作者
Ahmed, Ishaq [1 ]
Bandpei, Mohammad Ali Mohseni [2 ]
Gilani, Syed Amir [3 ]
Ahmad, Ashfaq [4 ]
Zaidi, Faryal [1 ]
机构
[1] Ibadat Int Univ Islamabad, Univ Inst Phys Therapy, Islamabad, Pakistan
[2] Univ Social Welf & Rehabil Sci, Pediat Neurorehabil Res Ctr, Tehran, Iran
[3] Univ Lahore, Lahore, Pakistan
[4] Univ Lahore, Univ Inst & Clin Phys Therapy, Lahore, Pakistan
关键词
Dual inclinometer; Inter-rater reliability; Intra-rater reliability; Landmarking; SPINAL RANGE; VALIDITY; MOBILITY; FLEXION;
D O I
10.47391/JPMA.4090
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Objective: To measure the intra-rater and inter-rater reliability of active lumbar extension and flexion movements using dual inclinometer with two different landmarking techniques. Method: The reliability study was conducted at the Physical Therapy Department of the University Teaching Hospital, The University of Lahore, Pakistan, in January 2020, and comprised patients of either gender aged >18 years with mild or symptomatic lower back pain, and healthy subjects s controls. Repeated measurements with dual inclinometer were taken by two examiners and data was recorded by two separate observers. A set of three active lumbar extension and flexion movements were performed for an initial warm-up. The examiners repeated a palpation of bony landmarks prior to each trial. The two different landmarking techniques were applied on the lumbar spine to identify the start and end points. Both the examiners measured each participant thrice. For each examiner and each landmarking technique, the three data sets were acquired for active lumbar extension and flexion for a total of 120 sets per session per examiner per landmarking. Each set comprised three alternating active lumbar extension and flexion movements. Data was analysed using SPSS version 26. Results: Of the 40 subjects with mean age 27.8+11.0 years, 19(48%) were males and 21(52%) were females. There were 15(38%) cases; 6(40%) males and 9(60%) females. The remaining 25(62%) were controls. The two landmarking techniques with dual inclinometer produced a high to very high intra-rater reliability (intraclass correlation coefficient:0.73-0.91) for both lumbar extension and flexion movements with moderate to low standard error of measurement values (0.36-1.31), while a high inter-rater reliability (intraclass correlation coefficient: 0.72-0.76; standard error of measurement: 0.52-0.63) for extension measurements and only moderate inter-rater reliability (intraclass correlation coefficient: 0.59-0.65; standard error of measurement: 1.36-1.49) for flexion measurements. Conclusion: Dual inclinometer along with skilled examiners and accurate landmarking methodology provided clinically reliable measurements.
引用
收藏
页码:1994 / 1997
页数:4
相关论文
共 50 条
  • [1] Lumbar range of motion: Reliability and validity of the inclinometer technique in the clinical measurement of trunk flexibility
    Saur, PMM
    Ensink, FBM
    Frese, K
    Seeger, D
    Hildebrandt, J
    [J]. SPINE, 1996, 21 (11) : 1332 - 1338
  • [2] RELIABILITY AND USE OF THE INCLINOMETER FOR CERVICAL RANGE OF MOTION MEASUREMENTS
    BARBEE, JA
    SANDSTEDT, AE
    PANICHELLA, JL
    CRANDELL, CE
    [J]. PHYSICAL THERAPY, 1988, 68 (05): : 826 - 827
  • [3] Reliability of hip internal rotation range of motion measurement using a digital inclinometer
    Krause, David A.
    Hollman, John H.
    Krych, Aaron J.
    Kalisvaart, Michael M.
    Levy, Bruce A.
    [J]. KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2015, 23 (09) : 2562 - 2567
  • [4] Reliability of hip internal rotation range of motion measurement using a digital inclinometer
    David A. Krause
    John H. Hollman
    Aaron J. Krych
    Michael M. Kalisvaart
    Bruce A. Levy
    [J]. Knee Surgery, Sports Traumatology, Arthroscopy, 2015, 23 : 2562 - 2567
  • [5] Comparison of Two Handheld Digital Dual Inclinometry Techniques in the Measurement of Lumbar Flexion Active Range of Motion
    Fletcher, James P.
    Taylor, James David
    Carroll, Chris A.
    Richardson, M. Blake
    [J]. JOURNAL OF SPORT REHABILITATION, 2021, 30 (02) : 339 - 342
  • [6] Reliability of three landmarking methods for dual inclinometry measurements of lumbar flexion and extension
    Joy C MacDermid
    Vanitha Arumugam
    Joshua I Vincent
    Kimberly L Payne
    Aubrey K So
    [J]. BMC Musculoskeletal Disorders, 16
  • [7] Reliability of three landmarking methods for dual inclinometry measurements of lumbar flexion and extension
    MacDermid, Joy C.
    Arumugam, Vanitha
    Vincent, Joshua I.
    Payne, Kimberly L.
    So, Aubrey K.
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2015, 16
  • [8] Reliability of Inclinometer-Derived Passive Range of Motion Measures in Youth with Cerebral Palsy
    Maltais, Desiree B.
    Ferland, Chantal
    Perron, Marc
    Roy, Jean-Sebastien
    [J]. PHYSICAL & OCCUPATIONAL THERAPY IN PEDIATRICS, 2019, 39 (06) : 655 - 668
  • [9] Validity and reliability of smartphone inclinometer applications for measurement of elbow range of motion in paediatric patients
    Koong, Denis P.
    Lee, Jillian
    Cheng, Tegan L.
    Little, David G.
    [J]. JOURNAL OF CHILDRENS ORTHOPAEDICS, 2020, 14 (05) : 488 - 494
  • [10] Validity and Reliability of a Smartphone and Digital Inclinometer in Measuring the Lower Extremity Joints Range of Motion
    Mohammad, Walaa S.
    Elattar, Faten F.
    Elsais, Walaa M.
    AlDajah, Salameh O.
    [J]. MONTENEGRIN JOURNAL OF SPORTS SCIENCE AND MEDICINE, 2021, 10 (02) : 47 - 52