Pulmonary Venous Anatomy Imaging With Low-Dose, Prospectively ECG-Triggered, High-Pitch 128-Slice Dual-Source Computed Tomography

被引:22
|
作者
Thai, Wai-ee [1 ,2 ]
Wai, Bryan [1 ,2 ]
Lin, Kaity [3 ]
Cheng, Teresa [1 ,2 ]
Heist, E. Kevin [3 ]
Hoffmann, Udo [1 ,2 ]
Singh, Jagmeet P. [3 ]
Truong, Quynh A. [1 ,2 ]
机构
[1] Harvard Univ, Div Cardiol, Cardiac MR PET CT Program, Massachusetts Gen Hosp,Med Sch, Boston, MA 02114 USA
[2] Harvard Univ, Dept Radiol, Sch Med, Massachusetts Gen Hosp, Boston, MA 02114 USA
[3] Harvard Univ, Cardiac Arrhythmia Serv, Sch Med, Massachusetts Gen Hosp, Boston, MA 02114 USA
来源
基金
美国国家卫生研究院;
关键词
arrhythmia (heart rhythm disorders); atrial fibrillation; computed tomography; imaging; pulmonary vein isolation; RADIOFREQUENCY CATHETER ABLATION; ATRIAL-FIBRILLATION; CT ANGIOGRAPHY; VEIN ISOLATION; FOLLOW-UP; RADIATION;
D O I
10.1161/CIRCEP.111.968313
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background-The efforts to reduce radiation from cardiac computed tomography (CT) are essential. Using a prospectively triggered, high-pitch dual-source CT protocol, we aim to determine the radiation dose and image quality in patients undergoing pulmonary vein (PV) imaging. Methods and Results-In 94 patients (61 +/- 9 years; 71% male) who underwent 128-slice dual-source CT (pitch 3.4), radiation dose and image quality were assessed and compared between 69 patients with sinus rhythm and 25 patients with atrial fibrillation. Radiation dose was compared in a subset of 19 patients with prior retrospective or prospectively triggered CT PV scans without high pitch. In a subset of 18 patients with prior magnetic resonance imaging for PV assessment, PV anatomy and scan duration were compared with high-pitch CT. Using the high-pitch protocol, total effective radiation dose was 1.4 (1.3, 1.9) mSv, with no difference between sinus rhythm and atrial fibrillation (1.4 versus 1.5 mSv; P=0.22). No high-pitch CT scans were nondiagnostic or had poor image quality. Radiation dose was reduced with high-pitch (1.6 mSv) compared with standard protocols (19.3 mSv; P<0.0001). This radiation dose reduction was seen with sinus rhythm (1.5 versus 16.7 mSv; P<0.0001) but was more profound with atrial fibrillation (1.9 versus 27.7 mSv; P=0.039). There was excellent agreement of PV anatomy (. 0.84; P<0.0001) and a shorter CT scan duration (6 minutes) compared with magnetic resonance imaging (41 minutes; P<0.0001). Conclusions-Using a high-pitch dual-source CT protocol, PV imaging can be performed with minimal radiation dose, short scan acquisition, and excellent image quality in patients with sinus rhythm or atrial fibrillation. This protocol highlights the success of new cardiac CT technology to minimize radiation exposure, giving clinicians a new low-dose imaging alternative to assess PV anatomy. (Circ Arrhythm Electrophysiol. 2012;5:521-530.)
引用
收藏
页码:521 / 530
页数:10
相关论文
共 50 条
  • [1] Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography
    Blanke, Philipp
    Baumann, Tobias
    Langer, Mathias
    Pache, Gregor
    [J]. EUROPEAN RADIOLOGY, 2010, 20 (08) : 1851 - 1855
  • [2] Imaging of pulmonary vein anatomy using low-dose prospective ECG-triggered dual-source computed tomography
    Philipp Blanke
    Tobias Baumann
    Mathias Langer
    Gregor Pache
    [J]. European Radiology, 2010, 20 : 1851 - 1855
  • [3] Low-Concentration Contrast Medium for 128-Slice Dual-Source CT Coronary Angiography at a Very Low Radiation Dose Using Prospectively ECG-Triggered High-Pitch Spiral Acquisition
    Zheng, Minwen
    Wu, Yongjie
    Wei, Mengqi
    Liu, Ying
    Zhao, Hongliang
    Li, Jian
    [J]. ACADEMIC RADIOLOGY, 2015, 22 (02) : 195 - 202
  • [4] Evaluation of high-pitch flash scan for pulmonary venous CTA on a 128-slice dual source CT: compared with prospective ECG-triggered sequence scan
    Li Xiu Cao
    Huan Zhang
    Bo Liu
    Wen Jie Yang
    Yan Yan Zhang
    Zi Lai Pan
    Fu Hua Yan
    Ke Min Chen
    [J]. The International Journal of Cardiovascular Imaging, 2013, 29 : 1557 - 1564
  • [5] Evaluation of high-pitch flash scan for pulmonary venous CTA on a 128-slice dual source CT: compared with prospective ECG-triggered sequence scan
    Cao, Li Xiu
    Zhang, Huan
    Liu, Bo
    Yang, Wen Jie
    Zhang, Yan Yan
    Pan, Zi Lai
    Yan, Fu Hua
    Chen, Ke Min
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2013, 29 (07): : 1557 - 1564
  • [6] Coronary computed tomography angiography during arrhythmia: Radiation dose reduction with prospectively ECG-triggered axial and retrospectively ECG-gated helical 128-slice dual-source CT
    Lee, Ashley M.
    Engel, Leif-Christopher
    Shah, Baiju
    Liew, Gary
    Sidhu, Manavjot S.
    Kalra, Mannudeep
    Abbara, Suhny
    Brady, Thomas J.
    Hoffmann, Udo
    Ghoshhajra, Brian B.
    [J]. JOURNAL OF CARDIOVASCULAR COMPUTED TOMOGRAPHY, 2012, 6 (03) : 172 - 183
  • [7] Benefits of High-Pitch 128-Slice Dual-Source Computed Tomography for Planning of Transcatheter Aortic Valve Implantation
    Plank, Fabian
    Friedrich, Guy
    Bartel, Thomas
    Mueller, Silvana
    Bonaros, Nikolaos
    Heinz, Anneliese
    Klauser, Andrea
    Cartes-Zumelzu, Fabiola
    Grimm, Michael
    Feuchtner, Gudrun
    [J]. ANNALS OF THORACIC SURGERY, 2012, 94 (06): : 1961 - 1966
  • [8] Low Dose High-Pitch Spiral Acquisition 128-Slice Dual-Source Computed Tomography for the Evaluation of Coronary Artery Bypass Graft Patency
    Goetti, Robert
    Leschka, Sebastian
    Baumueller, Stephan
    Plass, Andre
    Wieser, Monika
    Desbiolles, Lotus
    Stolzmann, Paul
    Falk, Volkmar
    Marincek, Borut
    Alkadhi, Hatem
    Feuchtner, Gudrun
    [J]. INVESTIGATIVE RADIOLOGY, 2010, 45 (06) : 324 - 330
  • [9] Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition
    Ghadri, Jelena R.
    Kueest, Silke M.
    Goetti, Robert
    Fiechter, Michael
    Pazhenkottil, Aju P.
    Nkoulou, Rene N.
    Kuhn, Felix P.
    Pietsch, Carsten
    von Schulthess, Patrick
    Gaemperli, Oliver
    Templin, Christian
    Kaufmann, Philipp A.
    [J]. INTERNATIONAL JOURNAL OF CARDIOVASCULAR IMAGING, 2012, 28 (05): : 1217 - 1225
  • [10] Image quality and radiation dose comparison of prospectively triggered low-dose CCTA: 128-slice dual-source high-pitch spiral versus 64-slice single-source sequential acquisition
    Jelena R. Ghadri
    Silke M. Küest
    Robert Goetti
    Michael Fiechter
    Aju P. Pazhenkottil
    Rene N. Nkoulou
    Felix P. Kuhn
    Carsten Pietsch
    Patrick von Schulthess
    Oliver Gaemperli
    Christian Templin
    Philipp A. Kaufmann
    [J]. The International Journal of Cardiovascular Imaging, 2012, 28 : 1217 - 1225