Hysteroscopic Endometrial Polypectomy: Clinical and Economic Data in Decision Making

被引:12
|
作者
Franchini, Mario [1 ]
Lippi, Giuseppe [1 ]
Calzolari, Stefano [1 ]
Giarre, Giovanna [1 ]
Gubbini, Giampietro [2 ]
Catena, Ursula [3 ]
Sardo, Attilio Di Spiezio [3 ]
Florio, Pasquale [4 ]
机构
[1] Hosp Ctr Florence Pietro Palagi, Florence, Italy
[2] Madre Fortunata Toniolo Clin, Bologna, Italy
[3] Univ Naples Federico II, Sch Med, Dept Publ Hlth, Naples, Italy
[4] San Iacopo Hosp, UOC Obstet & Gynecol, Via Ciliegiole, I-51100 Pistoia, Italy
关键词
Cost analysis; Hysteroscopy; Office setting; Operating room; Polyps; INTRAUTERINE MORCELLATOR; OPERATIVE HYSTEROSCOPY; ELECTRICAL RESECTION; COST-ANALYSIS; POLYPS; OUTPATIENT; ANESTHESIA; REMOVAL; RESECTOSCOPY; METAANALYSIS;
D O I
10.1016/j.jmig.2017.08.001
中图分类号
R71 [妇产科学];
学科分类号
100211 ;
摘要
Study Objective: To compare the costs of hysteroscopic polypectomy using mechanical and electrosurgical systems in the hospital operating room and an office-based setting. Design: Retrospective cohort study (Canadian Task Force classification II-2). Setting: Tertiary referral hospital and center for gynecologic care. Patients: Seven hundred and fifty-four women who underwent endometrial polypectomy between January 20, 2015, and April 27, 2016. Interventions: Hysteroscopic endometrial polypectomy performed in the same-day hospital setting or office setting using one of the following: bipolar electrode, loop electrode, mechanical device, or hysteroscopic tissue removal system. Measurements and Main Results: The various costs associated with the 2 clinical settings at Palagi Hospital, Florence, Italy were compiled, and a direct cost comparison was made using an activity-based cost-management system. The costs for using reusable loop electrode resection-16 or loop electrode resection-26 were significantly less expensive than using disposable loop electrode resection-27, the tissue removal system, or bipolar electrode resection (p=.0002). Total hospital costs for polypectomy with all systems were significantly less expensive in an office setting compared with same-day surgery in the hospital setting (p=.0001). Office-based hysteroscopic tissue removal was associated with shorter operative time compared with the other procedures (p=.0002) Conclusion: The total cost of hysteroscopic polypectomy is markedly higher when using disposable equipment compared with reusable equipment, both in the hospital operating room and the office setting. Same-day hospital or office-based surgery with reusable loop electrode resection is the most cost-effective approach in each settings, but requires experienced surgeons. Finally, the shorter surgical time should be taken into consideration for patients undergoing vaginal polypectomy in the office setting, owing more to patient comfort than to cost savings. (C) 2017 AAGL. All rights reserved.
引用
收藏
页码:418 / 425
页数:8
相关论文
共 50 条
  • [1] Pregnancy Rates after Hysteroscopic Endometrial Polypectomy versus Endometrial Curettage Polypectomy: A Retrospective Study
    Nishioka, Mikiko
    Maezawa, Tadashi
    Takeuchi, Hiroki
    Hagiwara, Katsuyuki
    Tarui, Sachiyo
    Sakamoto, Mito
    Takayama, Erina
    Yajima, Hideaki
    Kondo, Eiji
    Kawato, Hiroaki
    Minoura, Hiroyuki
    Sugaya, Ken
    Fukuda, Aisaku
    Ikeda, Tomoaki
    MEDICINA-LITHUANIA, 2023, 59 (10):
  • [2] Hysteroscopic endometrial polypectomy: outpatient versus conventional treatment
    Bergamo, Angela Mendes
    Depes, Daniella de Batista
    Gomes Pereira, Ana Maria
    Duarte de Santana, Taciana Cristina
    Lippi, Umberto Gazi
    Coelho Lopes, Reginaldo Guedes
    EINSTEIN-SAO PAULO, 2012, 10 (03): : 323 - 328
  • [3] Hysteroscopic polypectomy with endometrial resection preventing the recurrence of endometrial polyps: A single-blinded randomized clinical trial
    Vahdat, Mansoureh
    Mousavi, Ashraf Sadat
    Kaveh, Mania
    Sadegi, Kambiz
    Abdolahi, Hoda
    CASPIAN JOURNAL OF INTERNAL MEDICINE, 2022, 13 (02) : 393 - 397
  • [4] Comparison of Excision Results of Endometrial Polyps Hysteroscopic Polypectomy or Curettage
    Ulubay, Mustafa
    Ozturk, Mustafa
    Keskin, Ugur
    Fidan, Ulas
    Alanbay, Ibrahim
    Karasahin, Kazim Emre
    OBSTETRICS AND GYNECOLOGY, 2015, 125 : 30S - 30S
  • [5] Frequency of endometrial cancer and atypical hyperplasia in infertile women undergoing hysteroscopic endometrial polypectomy
    Kuribayshi, Y.
    Nakagawa, K.
    Sugiyama, R.
    Motoyama, H.
    Usui, C.
    Nishi, Y.
    Juen, H.
    Koro, Y.
    Hobo, R.
    Ino, N.
    Valckx, K.
    Inoue, M.
    Nishii, O.
    Akira, S.
    Sugiyama, R.
    HUMAN REPRODUCTION, 2016, 31 : 466 - 467
  • [6] Premalignant and malignant lesions in endometrial polyps in patients undergoing hysteroscopic polypectomy
    Lenci, Marco Antonio
    Lui do Nascimento, Vanessa Alessandra
    Grandini, Ana Beatriz
    Fahmy, Walid Makin
    Depes, Daniella de Batista
    Baracat, Fausto Farah
    Coelho Lopes, Reginaldo Guedes
    EINSTEIN-SAO PAULO, 2014, 12 (01): : 16 - 21
  • [7] The effect of hysteroscopic polypectomy on the concentrations of endometrial implantation factors in uterine flushings
    Ben-Nagi, J.
    Miell, J.
    Yazbek, J.
    Holland, T.
    Jurkovic, D.
    REPRODUCTIVE BIOMEDICINE ONLINE, 2009, 19 (05) : 737 - 744
  • [8] Hysteroscopic Endometrial Polypectomy with Manual Vacuum Aspiration Compared to Mechanical Morcellation
    Baikpour, Maryam
    Hurd, William W.
    JOURNAL OF MINIMALLY INVASIVE GYNECOLOGY, 2019, 26 (06) : 1050 - 1055
  • [9] Factors Influencing the Recurrence Potential of Benign Endometrial Polyps after Hysteroscopic Polypectomy
    Yang, Jehn-Hsiahn
    Chen, Chin-Der
    Chen, Shee-Uan
    Yang, Yu-Shih
    Chen, Mei-Jou
    PLOS ONE, 2015, 10 (12):
  • [10] Treatment outcomes of endometrial polypectomy using hysteroscopic tissue retrieval system (Truclear)
    Elhossamy, H.
    Arutchelvam, S.
    BJOG-AN INTERNATIONAL JOURNAL OF OBSTETRICS AND GYNAECOLOGY, 2021, 128 : 113 - 113