Automated Calibration for Optical See-Through Head Mounted Display Using Display Screen Space Based Eye Tracking

被引:0
|
作者
Bin Tomi, Azfar [1 ]
Rambli, Dayang Rohaya Awang [1 ]
机构
[1] Univ Teknol PETRONAS, Dept Comp Informat Sci, Bandar Seri Iskandar, Perak, Malaysia
关键词
Augmented Reality; Optical See-Through Head Mounted Display; Automated Calibration;
D O I
暂无
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
A crucial problem in Augmented Reality (AR) applications that used optical see-through head mounted display (OST HMD) is frequent (re) calibrations. It is considered time consuming and distract users from their application if each such frequent (re) calibrations involve user interactions. Furthermore, it will be prone to user-dependent errors into the system setup thus leads to reduce user's acceptance on OST HMD in AR applications. Nowadays, a few studies toward interaction-free calibration implementation on OST HMD have been done. Recent implementation on interaction-free calibration issues are associated with the virtual display calibration which is related to the eye and world camera relation with display screen. Thus, we propose a novel approach that utilizes a display screen space based eye tracking into OST HMD calibration. By simultaneously measuring eye movements and map the tracked eye coordinate into a 2D display screen space, a calibration formulation can be done without involving the eye tracker properties. This work is expected to be established for efficient and high accuracy interaction-free OST HMD calibration which will be beneficial in AR applications that used OST HMD.
引用
收藏
页码:448 / 453
页数:6
相关论文
共 50 条
  • [1] Spatial calibration of an optical see-through head-mounted display
    Gilson, Stuart J.
    Fitzgibbon, Andrew W.
    Glennerster, Andrew
    [J]. JOURNAL OF NEUROSCIENCE METHODS, 2008, 173 (01) : 140 - 146
  • [2] A structure of optical see-through head mounted display
    Kim, Jihyung
    Park, Sungeun
    Kim, Wooksung
    [J]. 2020 INTERNATIONAL CONFERENCE ON ELECTRONICS, INFORMATION, AND COMMUNICATION (ICEIC), 2020,
  • [3] Calibration of a stereo see-through head-mounted display
    Ghanai, S
    Eggers, G
    Muehling, J
    Marmulla, R
    Hassfeld, S
    Salb, T
    Dillmann, R
    [J]. PERSPECTIVE IN IMAGE-GUIDED SURGERY, 2004, : 461 - 467
  • [4] Display-relative calibration for optical see-through head-mounted displays
    Owen, CB
    Zhou, J
    Tang, A
    Xiao, F
    [J]. ISMAR 2004: THIRD IEEE AND ACM INTERNATIONAL SYMPOSIUM ON MIXED AND AUGMENTED REALITY, 2004, : 70 - 78
  • [5] Assessment of Optical See-Through Head Mounted Display Calibration for Interactive Augmented Reality
    Ballestin, Giorgio
    Chessa, Manuela
    Solari, Fabio
    [J]. 2019 IEEE/CVF INTERNATIONAL CONFERENCE ON COMPUTER VISION WORKSHOPS (ICCVW), 2019, : 4452 - 4460
  • [6] A Practical See-Through Head Mounted Display Using a Holographic Optical Element
    Ichiro KASAI
    Yasushi TANIJIRI
    Takeshi ENDO
    Hiroaki UEDA
    [J]. Optical Review, 2001, 8 : 241 - 244
  • [7] A practical see-through head mounted display using a holographic optical element
    Kasai, I
    Tanijiri, Y
    Endo, T
    Ueda, H
    [J]. OPTICAL REVIEW, 2001, 8 (04) : 241 - 244
  • [8] Evaluating Optical See-Through Head-Mounted Display Calibration via Frustum Visualization
    Moser, Kenneth R.
    Swan, J. Edward, II
    [J]. 2015 IEEE VIRTUAL REALITY CONFERENCE (VR), 2015, : 371 - 371
  • [9] A compact eyetracked optical see-through head-mounted display
    Hua, Hong
    Gao, Chunyu
    [J]. STEREOSCOPIC DISPLAYS AND APPLICATIONS XXIII, 2012, 8288
  • [10] Optical See-Through Head-Mounted Display with Occlusion Capability
    Gao, Chunyu
    Lin, Yuxiang
    Hua, Hong
    [J]. HEAD- AND HELMET-MOUNTED DISPLAYS XVIII: DESIGN AND APPLICATIONS, 2013, 8735