Differences in measurement of high-sensitivity troponin in an on-demand and batch-wise setting

被引:4
|
作者
Soerensen, Nils Arne [1 ,2 ]
Neumann, Johannes Tobias [1 ,2 ]
Ojeda, Francisco [1 ]
Renne, Thomas [3 ,4 ]
Karakas, Mahir [1 ,2 ]
Blankenberg, Stefan [1 ,2 ]
Westermann, Dirk [1 ,2 ]
Zeller, Tanja [1 ,2 ]
机构
[1] Univ Heart & Vasc Ctr Hamburg Eppendorf, Dept Cardiol, Hamburg, Germany
[2] German Ctr Cardiovasc Res DZHK, Partner Site Hamburg Kiel Lubeck, Hamburg, Germany
[3] Univ Med Ctr Hamburg Eppendorf, Inst Clin Chem & Lab Med, Hamburg, Germany
[4] Karolinska Inst, Dept Mol Med & Surg, Clin Chem, Stockholm, Sweden
关键词
Troponin I; troponin T; batch; on-demand; clinical routine; high-sensitivity; myocardial infarction; ACUTE MYOCARDIAL-INFARCTION; RULE-OUT; I ASSAY; EMERGENCY-DEPARTMENT; 1-HOUR ALGORITHM; 99TH PERCENTILE; EARLY-DIAGNOSIS; RAPID RULE; VALIDATION; CUTOFF;
D O I
10.1177/2048872620924198
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background: Most studies assessing the diagnostic value of high-sensitivity troponin in the diagnosis of myocardial infarction used batch-wise analyses of frozen samples for high-sensitivity troponin measurements. Whether the accuracy of these batch-wise high-sensitivity troponin measurements described in diagnostic studies is comparable to clinical routine is unknown. Methods: We enrolled 937 patients presenting with suspected myocardial infarction in this prospective cohort study. Measurements of high-sensitivity troponin I (Abbott Architect) and high-sensitivity troponin T (Roche) were performed in two settings: (a) on-demand in clinical routine using fresh blood samples; and (b) in batches using frozen blood samples from the same individuals at three timepoints (0 hours, 1 hour and 3 hours after presentation). Results: Median troponin levels were not different between on-demand and batch-wise measurements. Troponin levels in the range of 0 to 40 ng/L showed a very high correlation between the on-demand and batch setting (Pearson correlation coefficient (r) was 0.92-0.95 for high-sensitivity troponin I and 0.96 for high-sensitivity troponin T). However, at very low troponin levels (0 to 10 ng/L) correlation between the two settings was moderate (rfor high-sensitivity troponin I 0.59-0.66 and 0.65-0.69 for high-sensitivity troponin T). Application of guideline-recommended rapid diagnostic algorithms showed similar diagnostic performance with both methods. Conclusions: Overall on-demand and batch-wise measurements of high-sensitivity troponin provided similar results, but their correlation was moderate, when focusing on very low troponin levels. The application of rapid diagnostic algorithms was safe in both settings.
引用
收藏
页码:302 / 309
页数:8
相关论文
共 50 条
  • [1] SCHEDULING FOR KNOWN BUT IRREGULAR BATCH-WISE DEMAND
    KERNER, H
    [J]. OPERATIONAL RESEARCH QUARTERLY, 1961, 12 (04) : 226 - 243
  • [2] Interference in the measurement of troponin T by a high-sensitivity method
    Aliste Fernandez, M.
    Sole Enrech, G.
    Cano Corres, R.
    Berlanga Escalera, E.
    [J]. CLINICA CHIMICA ACTA, 2019, 493 : S180 - S180
  • [3] Population differences and high-sensitivity troponin values: a narrative review
    Lee, Deborah J. W.
    Aw, Tar-Choon
    [J]. JOURNAL OF LABORATORY AND PRECISION MEDICINE, 2023, 8 : 1 - 13
  • [4] Description of interference in the measurement of troponin T by a high-sensitivity method
    Aliste-Fernandez, Miguel
    Sole-Enrech, Gemma
    Cano-Corres, Ruth
    Teodoro-Marin, Silvia
    Berlanga-Escalera, Eugenio
    [J]. BIOCHEMIA MEDICA, 2019, 29 (02)
  • [5] Evaluation of Age and Sex Differences in Contemporary versus High-Sensitivity Troponin I Measurement in Hospitalized Patients
    Alkhalaileh, Hussam
    Wei, Ruhan
    Rivera, Ashly Cordero
    Goksel, Mustafa
    Lee, Jason K. Y.
    Mazzaferri Jr, Ernest
    Jones, Joanna
    Li, Jieli
    [J]. JOURNAL OF CLINICAL MEDICINE, 2024, 13 (08)
  • [6] Does high-sensitivity troponin measurement aid in the diagnosis of pulmonary embolism?
    Hogg, K.
    Haslam, S.
    Hinchliffe, E.
    Sellar, L.
    Lecky, F.
    Cruickshank, K.
    [J]. JOURNAL OF THROMBOSIS AND HAEMOSTASIS, 2011, 9 (02) : 411 - 412
  • [7] Diagnostic Performance of Serial High-Sensitivity Cardiac Troponin Measurements in the Emergency Setting
    Kavsak, Peter A.
    Hewitt, Mark K.
    Mondoux, Shawn E.
    Cerasuolo, Joshua O.
    Ma, Jinhui
    Clayton, Natasha
    McQueen, Matthew
    Griffith, Lauren E.
    Perez, Richard
    Seow, Hsien
    Ainsworth, Craig
    Ko, Dennis T.
    Worster, Andrew
    [J]. JOURNAL OF CARDIOVASCULAR DEVELOPMENT AND DISEASE, 2021, 8 (08)
  • [8] High-sensitivity cardiac troponin I in the clinical setting: a rapidly developing field
    Kotani, Kazuhiko
    Ishii, Junnichi
    [J]. ANNALS OF CLINICAL BIOCHEMISTRY, 2015, 52 (03) : 414 - 415
  • [9] High-sensitivity troponin in marathon runners
    Fatovich, Daniel M.
    Phillips, Michael R.
    Hubble, Kelley M.
    Vasikaran, Samuel D.
    [J]. MEDICAL JOURNAL OF AUSTRALIA, 2013, 199 (03) : 169 - 170
  • [10] High-Sensitivity Troponin: Time to Implement
    Hollander, Judd E.