Effects of chlorination and combined UV/Cl2 treatment on endotoxin activity and inhalation toxicity of lipopolysaccharide, gram-negative bacteria and reclaimed water

被引:21
|
作者
Xue, Jinling [1 ]
Zhang, Jinshan [1 ,3 ]
Qiao, Juan [2 ]
Lu, Yun [1 ]
机构
[1] Tsinghua Univ, Sch Environm, State Key Joint Lab Environm Simulat & Pollut Con, Beijing 100084, Peoples R China
[2] Tsinghua Univ, Dept Chem, Beijing 100084, Peoples R China
[3] Chengdu Environm Investment Grp Co LTD, Chengdu, Sichuan, Peoples R China
关键词
Endotoxin; Reclaimed water; Chlorination; UV; Inflammation; DEGRADATION; UV; UV/CHLORINE; INACTIVATION; REMOVAL; FEVER; RISK; LUNG;
D O I
10.1016/j.watres.2019.02.021
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Disinfection processes were applied in reclaimed water plant to eliminate pathogens and control the related health risk during water reuse. However, extra problems might emerge such as the released free endotoxins from the ruptured cell wall of gram-negative bacteria. Endotoxins can induce lung inflammatory responses after inhalation, which has been neglected in the water quality regulation, and the removal of endotoxin was not under consideration in the process of reclamation. In the present study, two well-known disinfection processes, chlorination and combined UV/chlorine (UV/Cl-2), were performed to test the removal efficiency of endotoxin activity, as well as the inflammation inducing ability. In the pure LPS solution, UV/Cl-2 treatment significantly reduced both endotoxin activity and lung inflammation responses with better oxidizability of the generated hydroxyl radical. However, its performance on bacteria liquid and real secondary effluent was more complicated. The cell wall-bound LPS have lower endotoxin activities and inflammation inducing ability. Immediately after the cell wall was destroyed, the bound LPS were released to the solution to be free LPS, which dramatically increased both the endotoxin activity and inflammation inducing ability of the water. When these free endotoxins were continuously oxidized, the endotoxin activity and inflammatory response decreased again but not to the background level. Therefore, the inflammation inducing ability of reclaimed water could not be removed efficiently. These results suggest that in spite of its high oxidability, UV/Cl-2 treatment is not capable of removing the endotoxin-based toxicity, and other technologies are necessary to control endotoxin levels in reclaimed water. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页码:124 / 130
页数:7
相关论文
共 11 条
  • [1] Effects of ozonation on the activity of endotoxin and its inhalation toxicity in reclaimed water
    Ren, Yunru
    Kong, Jiayang
    Xue, Jinling
    Shi, Xiaojie
    Li, Huijun
    Qiao, Juan
    Lu, Yun
    WATER RESEARCH, 2019, 154 : 153 - 161
  • [2] UV TREATMENT OF WATER FOR DESTRUCTION OF 5 GRAM-NEGATIVE BACTERIA PATHOGENIC TO FISHES
    BULLOCK, GL
    STUCKEY, HM
    JOURNAL OF THE FISHERIES RESEARCH BOARD OF CANADA, 1977, 34 (08): : 1244 - 1249
  • [3] COMBINED EFFECTS ON ANTIBACTERIAL ACTIVITY OF FATTY-ACIDS AND THEIR ESTERS AGAINST GRAM-NEGATIVE BACTERIA
    SHIBASAKI, I
    KATO, N
    JOURNAL OF THE AMERICAN OIL CHEMISTS SOCIETY, 1978, 55 (03) : A235 - A235
  • [4] The effects of LPS on the activity of Trp-containing antimicrobial peptides against Gram-negative bacteria and endotoxin neutralization
    Shang, Dejing
    Zhang, Qian
    Dong, Weibing
    Liang, Hao
    Bi, Xiaonan
    ACTA BIOMATERIALIA, 2016, 33 : 153 - 165
  • [5] Synergistic effects of a sequential recirculation electrochemical system combined with low-cost UV-LEDs on the gram-negative bacteria inactivation
    Paula Andrea Espinosa-Barrera
    Efraím A. Serna-Galvis
    Ricardo Antonio Torres-Palma
    David Izquierdo-Sandoval
    Félix Hernández
    Diana Martínez-Pachón
    Alejandro Moncayo-Lasso
    Environmental Science and Pollution Research, 2025, 32 (2) : 904 - 924
  • [6] IGG ANTIBODIES TO GRAM-NEGATIVE ENDOTOXIN IN HUMAN SERA .2. OPSONIC ACTIVITY OF CROSS-REACTIVE ANTIBODIES TO ENDOTOXIN CORE FOR ROUGH AND SMOOTH BACTERIA
    SCOTT, BB
    BARCLAY, GR
    SERODIAGNOSIS AND IMMUNOTHERAPY IN INFECTIOUS DISEASE, 1990, 4 (01) : 39 - 51
  • [7] Ultraviolet (Spot)light on Water Treatment: Targeting Inactivation Efficiency and Stress Responses of Gram-Positive and Gram-Negative Bacteria Using UV-B and UV-C LEDs
    Mutschlechner, Mira
    Chiste, Daniela
    Hauptmann, Daniel
    Schoebel, Harald
    WATER, 2024, 16 (14)
  • [8] Shape-dependent bactericidal activity of TiO2 for the killing of Gram-negative bacteria Agrobacterium tumefaciens under UV torch irradiation
    Aminedi, Raghavendra
    Wadhwa, Gunveen
    Das, Niranjan
    Pal, Bonamali
    ENVIRONMENTAL SCIENCE AND POLLUTION RESEARCH, 2013, 20 (09) : 6521 - 6530
  • [9] Shape-dependent bactericidal activity of TiO2 for the killing of Gram-negative bacteria Agrobacterium tumefaciens under UV torch irradiation
    Raghavendra Aminedi
    Gunveen Wadhwa
    Niranjan Das
    Bonamali Pal
    Environmental Science and Pollution Research, 2013, 20 : 6521 - 6530
  • [10] Effects of Aerosol Inhalation Combined with Intravenous Drip of Polymyxin B on Bacterial Clearance, Symptoms Improvement, and Serum Infection Indexes in Patients with Pneumonia Induced by Multidrug-Resistant Gram-Negative Bacteria
    Lin, Hanlu
    Liu, Xiaobo
    Sun, Pengfei
    EMERGENCY MEDICINE INTERNATIONAL, 2022, 2022