Signal-to-Noise Ratio Equalized Filtered Back-Projection for Positron Emission Tomography

被引:2
|
作者
Watson, Charles C. [1 ]
机构
[1] Siemens Med Solut Mol Imaging, Knoxville, TN 37932 USA
关键词
FBP; image reconstruction; PET; SNR; RECONSTRUCTION; SIMULATION; RESOLUTION; VARIANCE;
D O I
10.1109/TNS.2008.2006267
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We describe a new, noise-adaptive, quasi-linear image reconstruction algorithm for positron emission tomography that seeks to equalize the signal-to-noise ratio (SNR) across an image by applying spatially varying smoothing. It is based on the fact that for linear reconstruction algorithms such as filtered back-projection (FBP), operating on uncorrelated Poisson distributed data, it is possible to directly compute the corresponding noise variance image, and thus the SNR, at all points, for any smoothing kernel (or filter function). Increased smoothing generally results in higher SNR. Therefore, by varying the amount of smoothing locally, one can tune the image to achieve a target SNR at most points. The resulting image appears to share some of the advantages of maximum likelihood reconstruction (e.g., improved hot spot contrast versus noise trade-off) while retaining the quantitative advantages of FBP (biased only by the known smoothing kernel). Examples for clinical time-of-flight (TOF) and non-TOF reconstructions are shown.
引用
收藏
页码:108 / 115
页数:8
相关论文
共 50 条
  • [1] Signal-to-noise ratio equalized filtered back-projection for emission tomography
    Watson, Charles C.
    [J]. 2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 2776 - 2781
  • [2] Signal-to-noise ratio of arbitrarily filtered spontaneous emission
    Sprem, Marko
    Bosiljevac, Marko
    Babic, Dubravko
    [J]. PHYSICS AND SIMULATION OF OPTOELECTRONIC DEVICES XXVI, 2018, 10526
  • [3] Count rate dependence of local signal-to-noise ratio in positron emission tomography
    Watson, CC
    [J]. IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2004, 51 (05) : 2670 - 2680
  • [4] Parallelization of filtered back-projection algorithm for computed tomography
    Boukhamla, Akram
    Merouani, Hayet Farida
    Sissaoui, Hocine
    [J]. EVOLVING SYSTEMS, 2016, 7 (03) : 197 - 205
  • [5] Effects of size, contrast, and signal-to-noise ratio on tumor detection in positron emission tomography.
    Farquhar, TH
    Llacer, J
    Sayre, J
    Tai, YC
    Chatziioannou, A
    Czernin, J
    Dahlbom, M
    Gambhir, S
    Hoh, CK
    Huang, SC
    Levin, C
    MacDonald, LR
    Hoffman, EJ
    [J]. JOURNAL OF INVESTIGATIVE MEDICINE, 1999, 47 (02) : 82A - 82A
  • [6] Weighted Filtered Back-Projection for Source Translation Computed Tomography Reconstruction
    Chen, Jie
    Yu, Haijun
    Ni, Song
    Liu, Chuanjiang
    Ge, Wenjie
    Huang, Yixing
    Liu, Fenglin
    [J]. IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2023, 72
  • [7] POSITRON EMISSION TOMOGRAPHY WITH A LARGE AXIAL ACCEPTANCE ANGLE - SIGNAL-TO-NOISE CONSIDERATIONS
    KARP, JS
    KINAHAN, PE
    MANKOFF, DA
    [J]. IEEE TRANSACTIONS ON MEDICAL IMAGING, 1991, 10 (03) : 249 - 255
  • [8] Space Carving and Filtered Back-Projection as Preconditioners for Proton Computed Tomography Reconstruction
    Schultze, Blake
    Witt, Micah
    Schubert, Keith E.
    Hurley, Robert F.
    Bashkirov, Vladimir
    Schulte, Reinhard W.
    Gomez, Ernesto
    [J]. 2012 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE RECORD (NSS/MIC), 2012, : 4335 - 4340
  • [9] Optimization of Filtered Back-Projection for a Rayleigh Task
    Sanchez, Adrian A.
    Sidky, Emil Y.
    Pan, Xiaochuan
    [J]. 2013 IEEE NUCLEAR SCIENCE SYMPOSIUM AND MEDICAL IMAGING CONFERENCE (NSS/MIC), 2013,
  • [10] Filtered back-projection reconstruction technique for coherent-scatter computed tomography
    van Stevendaal, U
    Schlomka, JP
    Grass, M
    [J]. MEDICAL IMAGING 2003: IMAGE PROCESSING, PTS 1-3, 2003, 5032 : 1810 - 1819