Quantitation of residual WBCs in filtered blood components by high-throughput, real-time kinetic PCR

被引:15
|
作者
Lee, TH
Wen, L
Chrebtow, V
Higuchi, R
Watson, RM
Sninsky, JJ
Busch, MP
机构
[1] Irwin Ctr, Mol Biol Blood Ctr Pacific, Div Res, San Francisco, CA 94118 USA
[2] Roche Mol Syst Inc, Alameda, CA USA
[3] Blood Syst Inc, Scottsdale, AZ USA
[4] Univ Calif San Francisco, Dept Lab Med, San Francisco, CA 94143 USA
关键词
D O I
10.1046/j.1537-2995.2002.00009.x
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
BACKGROUND: The effort to eliminate transfusion complications associated with WBCs has led to the widespread use of filters able to reduce WBC concentrations to less than or equal to 0.1 WBC per muL blood. This has necessitated sensitive QC methods to quantitate residual WBCs in filtered units. One fast, effective method is DNA amplification using real-time kinetic PCR (kPCR). STUDY DESIGN AND METHODS: Two methods of preparation of standards were compared and used for the optimization of quantitative kPCR. The first involved spiking genomic DNA cell lysate into a diluent, followed by a series of 1 in 10 dilutions. The second involved spiking serial 1 in 10 dilutions of WBCs into twice-filtered fresh whole blood. Two hundred fifty filtered frozen whole-blood samples were amplified in duplicate to show the kPCR assay's reproducibility. Another 359 filtered frozen whole blood samples were used to compare data from kPCR with data from a standard PCR protocol using P-32-labeled probe and autoradiography. All specimens were amplified for conserved HLA DQalpha sequences. RESULTS: Standards prepared by both methods gave reproducible and equivalent results. Quantitation of standards representing a dynamic range of 8 x 10(0) to 8 x 10(5) WBCs per mL, yielded standard deviations ranging from 0.59 cycle to 1.04 cycles (a one-cycle increase is equivalent to a twofold increase in WBC concentration). The scatter graph of the 250 samples tested in duplicate by kPCR generated a slope of 1.0122 and an R-2 value of 0.9265. The comparison of kPCR and P-32-probe hybridization results on 359 clinical samples gave a scatter-graph slope of 0.9428 and an R 2 value of 0.8718, indicating excellent agreement of the methods over a 4-log dynamic range. CONCLUSION: kPCR is a high-throughput, sensitive assay that could prove useful in routine quality assurance of the WBC reduction process.
引用
收藏
页码:87 / 93
页数:7
相关论文
共 50 条
  • [1] Quantitation of residual white blood cells (WBC) in filtered blood components by high throughput, real time kinetic PCR
    Lee, T
    Wen, L
    Chrebtow, V
    Sninsky, JJ
    Higuchi, R
    Busch, MP
    TRANSFUSION, 1999, 39 (10) : 88S - 88S
  • [2] Automated high-throughput quantitation of residual Wbcs in filtered components by capillary cytometry
    Roback, JD
    Barclay, S
    Hillyer, CD
    TRANSFUSION, 2004, 44 (09) : 15A - 15A
  • [3] High-throughput real-time PCR for early detection and quantitation of arenavirus Tacaribe
    Grajkowska, Lucja T.
    Pedras-Vasconcelos, Joao A.
    Sauder, Christian
    Verthelyi, Daniela
    Puig, Montserrat
    JOURNAL OF VIROLOGICAL METHODS, 2009, 159 (02) : 239 - 243
  • [4] High-throughput real-time reverse transcription PCR quantitation of hepatitis C virus RNA
    Martell, M
    Gómez, J
    Esteban, JI
    Sauleda, S
    Quer, J
    Cabot, B
    Esteban, R
    Guardia, J
    JOURNAL OF CLINICAL MICROBIOLOGY, 1999, 37 (02) : 327 - 332
  • [5] A high-throughput pipeline for the design of real-time PCR signatures
    Ravi Vijaya Satya
    Kamal Kumar
    Nela Zavaljevski
    Jaques Reifman
    BMC Bioinformatics, 11
  • [6] A high-throughput pipeline for the design of real-time PCR signatures
    Satya, Ravi Vijaya
    Kumar, Kamal
    Zavaljevski, Nela
    Reifman, Jaques
    BMC BIOINFORMATICS, 2010, 11
  • [7] Detection of various blood group genotypes based on high-throughput real-time PCR technology
    Polin, H.
    Danzer, M.
    Proell, J.
    Hofer, K.
    Heilinger, U.
    Zopf, A.
    Nikolai, C.
    Gabriel, C.
    TRANSFUSION, 2007, 47 (03) : 178A - 178A
  • [8] Evaluation of the LightCycler® 1536 Instrument for high-throughput quantitative real-time PCR
    Schlesinger, Jenny
    Toenjes, Martje
    Schueler, Markus
    Zhang, Qin
    Dunkel, Ilona
    Sperling, Silke R.
    METHODS, 2010, 50 (04) : S19 - S22
  • [9] Residual subset population analysis in WBC-reduced blood components using real-time PCR quantitation of specific mRNA
    Pennington, J
    Garner, SF
    Sutherland, J
    Williamson, LM
    TRANSFUSION, 2001, 41 (12) : 1591 - 1600
  • [10] High-throughput detection, genotyping and quantification of the human papillomavirus using real-time PCR
    Micalessi, Isabel M.
    Boulet, Gaelle A. V.
    Bogers, Johannes J.
    Benoy, Ina H.
    Depuydt, Christophe E.
    CLINICAL CHEMISTRY AND LABORATORY MEDICINE, 2012, 50 (04) : 655 - 661