Open-Circuit Fault Diagnosis in PMSG Drives for Wind Turbine Applications

被引:234
|
作者
Freire, Nuno M. A. [1 ,2 ]
Estima, Jorge O. [1 ,2 ]
Marques Cardoso, Antonio J. [2 ,3 ]
机构
[1] Univ Coimbra, Fac Sci & Technol, Dept Elect & Comp Engn, P-3030290 Coimbra, Portugal
[2] Inst Telecomunicacoes, P-3030290 Coimbra, Portugal
[3] Univ Beira Interior, Dept Electromech Engn, P-6201001 Covilha, Portugal
关键词
Condition monitoring; fault diagnosis; multiple power switch open-circuit faults; permanent magnet machines; semiconductor device reliability; wind power generation; OPEN-SWITCH FAULTS; PWM INVERTER; POWER ELECTRONICS; RELIABILITY; SCHEME;
D O I
10.1109/TIE.2012.2207655
中图分类号
TP [自动化技术、计算机技术];
学科分类号
0812 ;
摘要
Condition monitoring and fault diagnosis are currently considered crucial means to increase the reliability and availability of wind turbines and, consequently, to reduce the wind energy cost. With similar goals, direct-drive wind turbines based on permanent magnet synchronous generators (PMSGs) with full-scale power converters are an emerging and promising technology. Numerous studies show that power converters are a significant contributor to the overall failure rate of modern wind turbines. In this context, open-circuit fault diagnosis in the two power converters of a PMSG drive for wind turbine applications is addressed in this paper. A diagnostic method is proposed for each power converter, allowing real-time detection and localization of multiple open-circuit faults. The proposed methods are suitable for integration into the drive controller and triggering remedial actions. In order to prove the reliability and effectiveness of the proposed fault diagnostic methods, several simulation and experimental results are presented.
引用
收藏
页码:3957 / 3967
页数:11
相关论文
共 50 条
  • [1] Converters Fault-Diagnosis in PMSG Drives for Wind Turbine Applications
    Freire, Nuno M. A.
    Estima, Jorge O.
    Marques Cardoso, A. J.
    [J]. IECON 2010: 36TH ANNUAL CONFERENCE OF THE IEEE INDUSTRIAL ELECTRONICS SOCIETY, 2010,
  • [2] Multiple Open-Circuit Faults Diagnosis in Back-to-Back Converters of PMSG Drives for Wind Turbine Systems
    Jlassi, Imed
    Estima, Jorge O.
    El Khil, Sejir Khojet
    Bellaaj, Najiba Mrabet
    Marques Cardoso, Antonio J.
    [J]. IEEE TRANSACTIONS ON POWER ELECTRONICS, 2015, 30 (05) : 2689 - 2702
  • [3] Open-circuit faults diagnosis in direct-drive PMSG wind turbine converter
    Zhang, Wei
    Ling, Qihui
    Zhao, Qiancheng
    Wu, Hushu
    [J]. Energy Engineering: Journal of the Association of Energy Engineering, 2021, 118 (05): : 1515 - 1535
  • [4] Inverter open-circuit fault diagnosis method in PMSG based wind energy conversion system
    Hedi Ben Mahdhi
    Hechmi Ben Azza
    Mohamed Jemli
    [J]. Electrical Engineering, 2022, 104 : 1317 - 1330
  • [5] Inverter open-circuit fault diagnosis method in PMSG based wind energy conversion system
    Ben Mahdhi, Hedi
    Ben Azza, Hechmi
    Jemli, Mohamed
    [J]. ELECTRICAL ENGINEERING, 2022, 104 (03) : 1317 - 1330
  • [6] Fault Tolerant Control in Direct-Drive PMSG Wind Turbine Systems under Open-Circuit Faults
    Bolbolnia, Rouhollah
    Heydari, Elham
    Abbaszadeh, Karim
    [J]. 2020 11TH POWER ELECTRONICS, DRIVE SYSTEMS, AND TECHNOLOGIES CONFERENCE (PEDSTC), 2020,
  • [7] Open-circuit and inter-turn short-circuit detection in PMSG for wind turbine applications using fuzzy logic
    Bechkaoui, A.
    Ameur, A.
    Bouras, S.
    Hadjadj, A.
    [J]. INTERNATIONAL CONFERENCE ON TECHNOLOGIES AND MATERIALS FOR RENEWABLE ENERGY, ENVIRONMENT AND SUSTAINABILITY -TMREES15, 2015, 74 : 1323 - 1336
  • [8] Simulation Study of DFIG Wind Turbine under Grid Fault Open-Circuit
    Abulizi, Maimaitireyimu
    Xie, Lirong
    Wang, Kaifeng
    [J]. 2019 IEEE 3RD INTERNATIONAL CONFERENCE ON GREEN ENERGY AND APPLICATIONS (ICGEA 2019), 2019, : 89 - 94
  • [9] Research of open-circuit fault simulation and diagnosis for wind power converter
    Zhang, Wei
    Ling, Qihui
    Zhao, Qiancheng
    Wang, Xian
    Zeng, Bing
    [J]. NINTH INTERNATIONAL SYMPOSIUM ON PRECISION MECHANICAL MEASUREMENTS, 2019, 11343
  • [10] Diagnosis of switch open-circuit fault in PM brushless DC motor drives
    Awadallah, MA
    Morcos, AA
    [J]. LESCOPE'03 : 2003 LARGE ENGINEERING SYSTEMS CONFERENCE ON POWER ENGINEERING, CONFERENCE PROCEEDINGS: ENERGY FOR THE FUTURE, 2003, : 69 - 73