Ultrasound Cyclo-Plasty in Patients with Glaucoma: 1-Year Results from a Multicentre Prospective Study

被引:32
|
作者
Giannaccare, Giuseppe [1 ]
Vagge, Aldo [2 ]
Sebastiani, Stefano [1 ]
Urbini, Lara E. [3 ]
Corazza, Paolo [2 ]
Pellegrini, Marco [1 ]
Carmassi, Luciana [3 ]
Bergamini, Fulvio [3 ]
Traverso, Carlo E. [2 ]
Campos, Emilio C. [1 ]
机构
[1] Univ Bologna, S Orsola Malpighi Univ Hosp, DIMES, Ophthalmol Unit, Bologna, Italy
[2] Univ Genoa, Eye Clin, DiNOGMI, Genoa, Italy
[3] Ist Auxol Italiano, IRCCS Fdn, Sci Inst Capitanio Hosp, Dept Ophthalmol, Milan, Italy
关键词
Glaucoma; Ultrasound cyclo-plasty; High-intensity focused ultrasound; Intraocular pressure; Ciliary body; INTENSITY FOCUSED ULTRASOUND; REFRACTORY GLAUCOMA; CILIARY BODY; DEVICE; LASER; CYCLOPHOTOCOAGULATION; CYCLOCOAGULATION;
D O I
10.1159/000487953
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
Purpose: The aim of this study was to evaluate the safety and efficacy of ultrasound cyclo-plasty (UCP) for reducing intraocular pressure (IOP) in patients with glaucoma. Methods: This is a multicentre prospective study conducted in 3 Italian glaucoma centres. UCP was performed by EyeOP1, which delivers ultrasound beams using 6 piezoelectric transducers activated for 4/6 s (first generation) or 8 s (second generation). Primary outcomes were the mean IOP reduction and the rates of success after 1 year. Secondary outcomes were the mean IOP reduction at each follow-up, and the reduction of the number of hypotensive medications. Results: In total, 49 eyes from 47 patients were treated. One year postoperatively, the mean IOP had decreased from 27.7 +/- 9.2 to 19.8 +/- 6.9 mm Hg (p < 0.001), and the mean number of hypotensive drops and tablets had decreased from 3.2 and 0.5 to 2.3 and 0.2, respectively (p < 0.05). Postoperative IOP reduction was significantly related to preoperative IOP (r(2) = 0.5034; p < 0.0001). Second-generation probes determined a significantly higher IOP reduction (p < 0.05). Qualified success was achieved in 25 eyes (51.1%) and complete success in 21 (42.9%), while failure was recorded in 12 (24.5%). Conclusions: UCP is safe and effective for reducing IOP. The procedure determines a greater IOP reduction in patients with higher preoperative IOP. Second-generation probes improve outcomes without detrimental effects on safety. (C) 2018 S. Karger AG, Basel
引用
收藏
页码:137 / 142
页数:6
相关论文
共 50 条
  • [1] Ultrasound cyclo-plasty for moderate glaucoma: Eighteen-month results from a prospective study
    Wang, Rui-Xue
    Li, Ning
    Chen, Xiao-Ya
    FRONTIERS IN MEDICINE, 2022, 9
  • [2] Efficacy and safety of single Ultrasound Cyclo-Plasty to treat refractory glaucoma: Results at 1 year
    Zhou Longfang
    Hu Die
    Lan Jie
    Liu Yameng
    Lv Mingyuan
    Pan Xiaojing
    EUROPEAN JOURNAL OF OPHTHALMOLOGY, 2022, 32 (01) : 268 - 274
  • [3] A 2-year prospective multicenter study of ultrasound cyclo plasty for glaucoma
    Giuseppe Giannaccare
    Marco Pellegrini
    Federico Bernabei
    Lara Urbini
    Fulvio Bergamini
    Lorenzo Ferro Desideri
    Alessandro Bagnis
    Francesco Biagini
    Paola Cassottana
    Chiara Del Noce
    Adriano Carnevali
    Vincenzo Scorcia
    Carlo E. Traverso
    Aldo Vagge
    Scientific Reports, 11
  • [4] A 2-year prospective multicenter study of ultrasound cyclo plasty for glaucoma
    Giannaccare, Giuseppe
    Pellegrini, Marco
    Bernabei, Federico
    Urbini, Lara
    Bergamini, Fulvio
    Desideri, Lorenzo Ferro
    Bagnis, Alessandro
    Biagini, Francesco
    Cassottana, Paola
    Del Noce, Chiara
    Carnevali, Adriano
    Scorcia, Vincenzo
    Traverso, Carlo E.
    Vagge, Aldo
    SCIENTIFIC REPORTS, 2021, 11 (01)
  • [5] Efficacy and safety of high-intensity focused ultrasound cyclo-plasty in glaucoma
    Chen, Di
    Guo, Xiu-Juan
    Luo, Shu-Ke
    Lu, Yan
    Tang, Xiu-Rong
    BMC OPHTHALMOLOGY, 2022, 22 (01)
  • [6] Efficacy and safety of high-intensity focused ultrasound cyclo-plasty in glaucoma
    Di Chen
    Xiu-Juan Guo
    Shu-Ke Luo
    Yan Lu
    Xiu-Rong Tang
    BMC Ophthalmology, 22
  • [7] Efficacy and safety of high-dose ultrasound cyclo-plasty procedure in refractory glaucoma
    Liu, He-Ting
    Zhang, Qing
    Jiang, Zheng-Xuan
    Xu, Yu-Xin
    Wan, Qian-Qian
    Tao, Li-Ming
    INTERNATIONAL JOURNAL OF OPHTHALMOLOGY, 2020, 13 (09) : 1391 - 1396
  • [8] Efficacy and safety of high-dose ultrasound cyclo-plasty procedure in refractory glaucoma
    He-Ting Liu
    Qing Zhang
    Zheng-Xuan Jiang
    Yu-Xin Xu
    Qian-Qian Wan
    Li-Ming Tao
    International Journal of Ophthalmology, 2020, (09) : 1391 - 1396
  • [9] High intensity focused ultrasound for glaucoma: 1-year results from a prospective pragmatic study
    Raquel E. Marques
    Nuno P. Ferreira
    David C. Sousa
    André Diogo Barata
    Paula Sens
    Carlos Marques-Neves
    Luis Abegão Pinto
    Eye, 2021, 35 : 484 - 489
  • [10] High intensity focused ultrasound for glaucoma: 1-year results from a prospective pragmatic study
    Marques, Raquel E.
    Ferreira, Nuno P.
    Sousa, David C.
    Barata, Andre Diogo
    Sens, Paula
    Marques-Neves, Carlos
    Pinto, Luis Abegao
    EYE, 2021, 35 (02) : 484 - 489