Determination of inorganic antimony species in seawater by differential pulse anodic stripping voltammetry: stability of the trivalent state

被引:84
|
作者
Quentel, F
Filella, M
机构
[1] Univ Bretagne Occidentale, CNRS, UMR 6521, Lab Chim Anal, F-29285 Brest, France
[2] Univ Geneva, Dept Chim Minerale Anal & Appl, CH-1211 Geneva 4, Switzerland
关键词
differential pulse anodic stripping voltammetry antimony species; seawater;
D O I
10.1016/S0003-2670(01)01474-X
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
A simple method is described for the rapid and reliable determination of ultratrace concentrations of Sb(III) and Sb(V) in seawater by differential pulse anodic stripping voltammetry. It is based on the well-known dependence of Sb(III)/Sb(V) voltammetric response on acidity conditions. Under our optimised conditions (0.5 mol l(-1) HCl for Sb(III) and 5 mol l(-1) HCI for total Sb, respectively): (i) a detection limit of 11 ng l(-1) is obtained for a 10 min deposition time; (ii) no prior elimination of organic matter is needed; and (iii) antimony can be determined in the presence of natural copper levels. Particular care has been taken in order to understand the chemical processes taking place in all the solutions and reactions involved in the sampling and measuring procedures. Our results revealed the need to consider (i) the effect of photooxydation of synthetic and seawater samples on Sb speciation; and (ii) the stability of Sb(III) both in seawater samples and in the analytical solutions. (C) 2002 Elsevier Science B.V. All rights reserved.
引用
收藏
页码:237 / 244
页数:8
相关论文
共 50 条
  • [1] DETERMINATION OF ARSENIC BY ANODIC STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY
    OLAUGHLI.JW
    FORSBERG, G
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1973, (AUG26): : 34 - 34
  • [2] DETERMINATION OF ANTIMONY(III) AND ANTIMONY(V) BY DIFFERENTIAL-PULSE ANODIC-STRIPPING VOLTAMMETRY
    WALLER, PA
    PICKERING, WF
    TALANTA, 1995, 42 (02) : 197 - 204
  • [3] DETERMINATION OF ARSENIC BY ANODIC-STRIPPING VOLTAMMETRY AND DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY
    FORSBERG, G
    OLAUGHLIN, JW
    MEGARGLE, RG
    KOIRTYOHANN, SR
    ANALYTICAL CHEMISTRY, 1975, 47 (09) : 1586 - 1592
  • [4] Determination of thallium by differential pulse anodic stripping voltammetry
    Karbowska, Bozena
    Zembrzuski, Wlodzimierz
    Wojtkowiak, Tomasz
    Lukaszewski, Zenon
    PRZEMYSL CHEMICZNY, 2014, 93 (06): : 978 - 982
  • [5] DIFFERENTIAL PULSE ANODIC STRIPPING VOLTAMMETRY FOR MERCURY DETERMINATION
    Verestiuc, Paul C.
    Tucaliuc, Oana-Maria
    Breaban, Iuliana G.
    Cretescu, Igor
    Nemtoi, Gheorghe
    ACTA CHEMICA IASI, 2015, 23 (01) : 13 - 24
  • [6] Differential pulse anodic stripping voltammetry of lead and antimony in gunshot residues
    Woolever, CA
    Starkey, DE
    Dewald, HD
    FORENSIC SCIENCE INTERNATIONAL, 1999, 102 (01) : 45 - 50
  • [7] Determination of Antimony in Steel by Differential Pulse Anodic Stripping Voltammetry at a Rotating Gold Film Electrode
    Tatsuhiko Tanaka
    Takashi Ishiyama
    Kumi Okamoto
    Analytical Sciences, 2000, 16 : 19 - 24
  • [8] Determination of antimony in steel by differential pulse anodic stripping voltammetry at a rotating gold film electrode
    Tanaka, T
    Ishiyama, T
    Okamoto, K
    ANALYTICAL SCIENCES, 2000, 16 (01) : 19 - 23
  • [9] DETERMINATION OF ANTIMONY(III) ANTIMONY(V) BY DIFFERENTIAL PULSE ANODIC-STRIPPING VOLTAMMETRY AFTER EXTRACTION INTO ACETONITRILE
    NAGAOSA, Y
    SANA, T
    BUNSEKI KAGAKU, 1984, 33 (01) : 22 - 26
  • [10] Determination of Iodine Ion by Differential Pulse Anodic Stripping Voltammetry
    Tian, Yuan
    Song, Wen-Bo
    Jiang, Yan-Xia
    Liu, Ying
    Chen, Xu
    Xu, Hong-Ding
    Kao Teng Hsueh Hsiao Hua Heush Hsueh Pao/ Chemical Journal of Chinese Universities, 20 (01): : 30 - 31