High resolution in-vivo intraarterial imaging with optical coherence tomography

被引:0
|
作者
Boppart, SA [1 ]
Pitris, C [1 ]
Ghanta, RK [1 ]
Li, XD [1 ]
Drexler, W [1 ]
Fujimoto, JG [1 ]
Brezinski, ME [1 ]
机构
[1] MIT, Elect Res Lab, Dept Elect Engn & Comp Sci, Cambridge, MA 02139 USA
关键词
optical coherence tomography; OCT; atherosclerosis; stent; plaque; coronary artery;
D O I
10.1117/12.350978
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
High resolution imaging of intraarterial structure is necessary for the identification of high risk coronary plaque. Optical Coherence Tomography (OCT), a recently developed technology, is a compact, fiber optic based imaging modality with resolutions between 2 - 20 mu m and real time image acquisition rates. Previous in vitro studies have demonstrated the capability of OCT to identify plaque morphology and distinguish plaques with high lipid content. This work demonstrates the feasibility for OCT imaging of in-vivo intraarterial structures. We demonstrate the detection of microstructural detail and the effects of blood on imaging. Saline injections were required during imaging to reduce the signal attenuation of blood. An axial resolution of 10 mu m was achieved. Microstructure within the arterial wall was sharply defined and correlated with histology. OCT shows potential to assist in the risk stratification of plaques and the guidance of interventional procedures, such as stent deployment.
引用
收藏
页码:324 / 327
页数:4
相关论文
共 50 条
  • [1] High resolution in-vivo imaging of skin with full field optical coherence tomography
    Dalimier, E.
    Bruhat, A.
    Grieve, K.
    Harms, F.
    Martins, F.
    Boccara, C.
    PHOTONIC THERAPEUTICS AND DIAGNOSTICS X, 2014, 8926
  • [2] High-resolution imaging of microvasculature in human skin in-vivo with optical coherence tomography
    Liu, Gangjun
    Jia, Wangcun
    Sun, Victor
    Choi, Bernard
    Chen, Zhongping
    OPTICS EXPRESS, 2012, 20 (07): : 7694 - 7705
  • [3] IN-VIVO RETINAL IMAGING BY OPTICAL COHERENCE TOMOGRAPHY
    SWANSON, EA
    IZATT, JA
    HEE, MR
    HUANG, D
    LIN, CP
    SCHUMAN, JS
    PULIAFITO, CA
    FUJIMOTO, JG
    OPTICS LETTERS, 1993, 18 (21) : 1864 - 1866
  • [4] In-vivo high resolution thoracoscopic Optical Coherence Tomography imaging of induced pleural tumors.
    Armstrong, J
    Matheny, E
    Kreuter, K
    Hanna, N
    Chen, Z
    Guo, S
    Mukai, D
    Mahon, S
    Brenner, M
    JOURNAL OF INVESTIGATIVE MEDICINE, 2005, 53 (01) : S112 - S112
  • [5] HIGH-SPEED IN-VIVO RETINAL IMAGING WITH OPTICAL COHERENCE TOMOGRAPHY
    IZATT, JA
    HEE, MR
    HUANG, D
    SWANSON, EA
    LIN, CP
    SCHUMAN, JS
    PULIAFITO, CA
    FUJIMOTO, JG
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1994, 35 (04) : 1729 - 1729
  • [6] MICROMETER-SCALE RESOLUTION IMAGING OF THE ANTERIOR EYE IN-VIVO WITH OPTICAL COHERENCE TOMOGRAPHY
    IZATT, JA
    HEE, MR
    SWANSON, EA
    LIN, CP
    HUANG, D
    SCHUMAN, JS
    PULIAFITO, CA
    FUJIMOTO, JG
    ARCHIVES OF OPHTHALMOLOGY, 1994, 112 (12) : 1584 - 1589
  • [7] IN-VIVO OPTICAL COHERENCE TOMOGRAPHY
    FERCHER, AF
    HITZENBERGER, CK
    DREXLER, W
    KAMP, G
    SATTMANN, H
    AMERICAN JOURNAL OF OPHTHALMOLOGY, 1993, 116 (01) : 113 - 115
  • [8] Optical coherence tomography for ultrahigh resolution in vivo imaging
    Fujimoto, JG
    NATURE BIOTECHNOLOGY, 2003, 21 (11) : 1361 - 1367
  • [9] Optical coherence tomography for ultrahigh resolution in vivo imaging
    James G Fujimoto
    Nature Biotechnology, 2003, 21 : 1361 - 1367
  • [10] High resolution in vivo intra-arterial imaging with optical coherence tomography
    Fujimoto, JG
    Boppart, SA
    Tearney, GJ
    Bouma, BE
    Pitris, C
    Brezinski, ME
    HEART, 1999, 82 (02) : 128 - 133