Mechanical ventilation in critically-ill pregnant women: a case series

被引:29
|
作者
Lapinsky, S. E. [1 ,2 ]
Rojas-Suarez, J. A. [3 ,4 ]
Crozier, T. M. [5 ,6 ]
Vasquez, D. N. [7 ]
Barrett, N. [6 ]
Austin, K. [1 ]
Plotnikow, G. A. [7 ]
Orellano, K. [4 ,8 ]
Bourjeily, G. [9 ,10 ]
机构
[1] Mt Sinai Hosp, Intens Care Unit, Toronto, ON M5G 1X5, Canada
[2] Univ Toronto, Interdept Div Crit Care Med, Toronto, ON, Canada
[3] Gest Salud Clin, Intens Care Unit, Cartagena, Colombia
[4] Univ Cartagena, Gest Salud Clin, GRICIO, Cartagena, Colombia
[5] Monash Med Ctr, Intens Care Unit, Clayton, Vic 3168, Australia
[6] Monash Univ, Sch Clin Sci, Dept Obstet & Gynaecol, Ritchie Ctr, Clayton, Vic, Australia
[7] Sanatorio Anchorena, Buenos Aires, DF, Argentina
[8] Univ Sinu, Cartagena, Colombia
[9] Brown Univ, Dept Med, Warren Alpert Med Sch, Pulm & Crit Care Med, Providence, RI 02912 USA
[10] Miriam Hosp, Providence, RI 02906 USA
关键词
Delivery; Obstetric; Intensive care; Pregnancy complications; Respiration; Artificial; Respiratory insufficiency; RESPIRATORY-DISTRESS-SYNDROME; ACUTE LUNG INJURY; FETAL OXYGENATION; BLOOD-FLOW; DELIVERY; PATIENT;
D O I
10.1016/j.ijoa.2015.06.009
中图分类号
R614 [麻醉学];
学科分类号
100217 ;
摘要
Background: Approximately 0.1-0.2% of pregnancies are complicated by respiratory failure requiring mechanical ventilatory support, but few data exist to inform clinical management. This study aimed to characterize current practice and the effect of delivery on respiratory function. Methods: A retrospective review was perfoinied of pregnant women who received mechanical ventilation for more than 24 h, from four intensive care units in institutions with large-volume obstetric units. Results: Data were collected from 29 patients with a mean gestation at intensive care unit admission of 25.3 +/- 6 weeks. Tidal volumes were 7.7 +/- 1.7 mL/kg predicted body weight. Estimated respiratory system compliance was reduced, but was higher in four patients ventilated for neurological conditions without lung disease. Three maternal and three neonatal deaths occurred. Ten patients delivered while on ventilatory support: one spontaneous delivery, four for obstetric indications and five for worsening maternal condition. Following delivery of these 10 patients, three demonstrated a greater than 50% decrease in oxygenation index and five a greater than 50% increase in compliance. No characteristics identified which patients may benefit from delivery. Conclusions: Review of current practice in four centers suggests that mechanical ventilation in pregnant patients follows usual guidelines applicable to non-pregnant patients. Delivery was associated with modest improvement in maternal respiratory function in some patients. Any potential benefit of delivery in improving maternal physiology must be weighed against the stress of delivery. The risks of premature birth for the fetus must be weighed against continued exposure to maternal hypoxemia and hypotension. (C) 2015 Elsevier Ltd. All rights reserved.
引用
收藏
页码:323 / 328
页数:6
相关论文
共 50 条
  • [1] MECHANICAL VENTILATION IN CRITICALLY ILL PREGNANT WOMEN
    Lapinsky, S. E.
    Austin, K.
    Mehta, S.
    [J]. INTENSIVE CARE MEDICINE, 2014, 40 : S91 - S91
  • [2] Shoshin Beriberi in Critically-Ill patients: case series
    Dabar, George
    Harmouche, Carine
    Habr, Bassem
    Riachi, Moussa
    Jaber, Bertrand
    [J]. NUTRITION JOURNAL, 2015, 14
  • [3] Shoshin Beriberi in Critically-Ill patients: case series
    George Dabar
    Carine Harmouche
    Bassem Habr
    Moussa Riachi
    Bertrand Jaber
    [J]. Nutrition Journal, 14
  • [4] Challenges and pitfalls of extracorporeal membrane oxygenation in critically-ill pregnant and peripartum women with COVID-19: a retrospective case series
    Piwowarczyk, P.
    Porzak, M.
    Szczukocka, M.
    Miturski, A.
    Kazirod, K.
    Kwasniewski, W.
    Czuczwar, M.
    Borys, M.
    [J]. INTERNATIONAL JOURNAL OF OBSTETRIC ANESTHESIA, 2023, 53
  • [5] SAFETY AND EFFICACY OF THE ABCDE BUNDLE IN CRITICALLY-ILL PATIENTS RECEIVING MECHANICAL VENTILATION
    Balas, Michele
    Olsen, Keith
    Gannon, David
    Sisson, Joseph
    Sullivan, James
    Stothert, Joseph
    Jawa, Randeep
    Vasilevskis, Eduard
    Burke, William
    Ely, Wes
    [J]. CRITICAL CARE MEDICINE, 2012, 40 (12) : U18 - U18
  • [6] Implications of a comprehensive clinical approach in the treatment of critically-ill patients requiring mechanical ventilation
    Roche-Campo, F.
    Mancebo, J.
    [J]. MINERVA ANESTESIOLOGICA, 2011, 77 (05) : 477 - 479
  • [7] Tracheal Intubation and Mechanical Ventilation for Critically Ill Patients with Salicylate Poisoning: A Case Series
    Mcdonald, B. A.
    Conlon, M.
    Ulici, A.
    Cole, J.
    Olives, T.
    Kempainen, R. R.
    Prekker, M. E.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2022, 205
  • [8] Editorial: The Pulmonary and extra-pulmonary effects of mechanical ventilation in critically-ill patients
    Gattarello, Simone
    Busana, Mattia
    Cortes-Puentes, Gustavo A.
    [J]. FRONTIERS IN MEDICINE, 2023, 10
  • [9] Neuromuscular Blocking Agents in Critically-Ill COVID-19 Patients Requiring Mechanical Ventilation
    Li Bassi, G.
    Gibbons, K.
    Suen, J.
    Dalton, H. J.
    White, N.
    Barnett, A.
    Fraser, J.
    [J]. AMERICAN JOURNAL OF RESPIRATORY AND CRITICAL CARE MEDICINE, 2021, 203 (09)
  • [10] Mechanical ventilation in critically ill patients
    Levin, BS
    Rosenthal, MH
    [J]. BAILLIERES CLINICAL ANAESTHESIOLOGY, 1996, 10 (01): : 155 - 180