Power Quality Improvement Using Shunt Active Power Filter

被引:0
|
作者
Patil, Sagar S. [1 ]
Metri, R. A. [2 ]
机构
[1] Rajarambapu Inst Technol, Dept Elect Engn, Elect Power Syst, Islampur 415414, India
[2] Rajarambapu Inst Technol, Dept Elect Engn, Islampur 415414, India
关键词
Eliminating the harmonics; Shunt Active Power Filter (SAPF); hysteresis current controller;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
In recent years, power electronics devices have evolved, and used for varies applications. Also, this device caused the problem of power quality in electrical system. In the utility side arc furnaces, variable frequency drives (VFD), personal computer, fluorescent lamp such non-linear load produces current harmonics. For consumer and distributed side the power quality is an important issue. The active power filter which is capable for improving the power quality and reactive power compensation. In this paper the harmonics problem which is created by non-linear load is discussed. Shunt active filter is used for eliminating the harmonics from non-linear load and in the retrieval technique for controlling the current hysteresis current controller is used. In this paper for producing the reference current instantaneous reactive power (PQ) theory is used. The simulation result of shunt active filter using PQ theory is carried out using matlab-simulink toolbox.
引用
收藏
页码:152 / 156
页数:5
相关论文
共 50 条
  • [1] Power Quality Improvement using Shunt Active Filter
    Archana, K.
    Sumukha, M. S.
    Thousif, Mohammed M.
    [J]. 2017 INTERNATIONAL CONFERENCE ON CURRENT TRENDS IN COMPUTER, ELECTRICAL, ELECTRONICS AND COMMUNICATION (CTCEEC), 2017, : 622 - 626
  • [2] Power Quality Improvement by using Shunt Hybrid Active Power Filter
    Tahmid, Rashik
    Ahmad, Shameem
    [J]. 2017 INTERNATIONAL CONFERENCE ON ELECTRICAL, COMPUTER AND COMMUNICATION ENGINEERING (ECCE), 2017, : 381 - 386
  • [3] Improvement. of power quality using adaptive shunt active filter
    Tey, LH
    So, PL
    Chu, YC
    [J]. IEEE TRANSACTIONS ON POWER DELIVERY, 2005, 20 (02) : 1558 - 1568
  • [4] A PV powered shunt active power filter for power quality improvement
    Ayoub Benzahia
    Rabhi Boualaga
    Ammar Moussi
    Laeid Zellouma
    Memich Meriem
    Bouziane Chaima
    [J]. Global Energy Interconnection, 2019, 2 (02) : 143 - 149
  • [5] Power Quality Improvement of Microgrid Using Double Bridge Shunt Active Power Filter (DBSAPF)
    Meena, Rajesh Kumar
    Kumar, Dheeraj
    Jadoun, Vinay Kumar
    Pandey, Saurabh Kumar
    [J]. INTELLIGENT COMPUTING TECHNIQUES FOR SMART ENERGY SYSTEMS, 2020, 607 : 475 - 483
  • [6] Power Quality Improvement Features for a Distributed Generation System using Shunt Active Power Filter
    Premalatha, S.
    Dash, Subhransu Sekhar
    Babu, Paduchuri Chandra
    [J]. INTERNATIONAL CONFERENCE ON DESIGN AND MANUFACTURING (ICONDM2013), 2013, 64 : 265 - 274
  • [7] Improvement of Power Quality in an Electric Arc Furnace Using Shunt Active Filter
    Vinayaka, K. U.
    Puttaswamy, P. S.
    [J]. EMERGING RESEARCH IN ELECTRONICS, COMPUTER SCIENCE AND TECHNOLOGY, ICERECT 2018, 2019, 545 : 1255 - 1269
  • [8] Fuzzy Logic Control of Shunt Active Power Filter for Power Quality Improvement
    Anjana, S.
    Maya, P.
    [J]. PROCEEDINGS OF THE INTERNATIONAL CONFERENCE ON SOFT COMPUTING SYSTEMS, ICSCS 2015, VOL 1, 2016, 397 : 975 - 985
  • [9] Indirect current controlled shunt active power filter for power quality improvement
    Mahanty, R.
    [J]. INTERNATIONAL JOURNAL OF ELECTRICAL POWER & ENERGY SYSTEMS, 2014, 62 : 441 - 449
  • [10] Fuzzy logic controlled shunt active power filter for power quality improvement
    Jain, SK
    Agrawal, P
    Gupta, HO
    [J]. IEE PROCEEDINGS-ELECTRIC POWER APPLICATIONS, 2002, 149 (05): : 317 - 328