Neutron spectra and the ambient dose equivalent were estimated inside the radiotherapy hall with an 18 MV linac. Estimations were carried out using Monte Carlo methods where a realist hall was modeled including a phantom made of equivalent tissue. The source term for photoneutrons was calculated using the Tosi et al. function that account for evaporation and knock-on neutrons. The spectra were estimated using two different energy distributions. Detectors were located in several sites inside the hall including the maze and outside the hall door, all detectors were located at the plane were the isocenter is located. In the treatment hall, as the distance respect to the isocenter is increased, the amount of neutrons and the H*(10) are reduced, neutrons in the high-energy region are shifted to lower region peaking around 0.1 MeV, however the epithermal and thermal neutrons remain constant due to the room-return effect. In the maze the spectra are dominated by epithermal and thermal neutrons that contributes to produce activation and the production of prompt gamma-rays.
引用
收藏
页码:192 / 194
页数:3
相关论文
共 50 条
  • [1] Neutron Spectra and H*(10) in a 15 MV Linac
    Benites, J.
    Vega-Carrillo, H. R.
    Hernandez-Davila, V. M.
    Rivera, T.
    Carrillo, A.
    Mondragon, R.
    [J]. ELEVENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2010, 1310 : 44 - +
  • [2] Neutron H*(10) estimation and measurements around 18 MV linac
    Ceron Ramirez, Pablo Victor
    Diaz Gongora, Jose Antonio Iran
    Paredes Gutierrez, Lydia Concepcion
    Rivera Montalvo, Teodoro
    Vega Carrillo, Hector Rene
    [J]. APPLIED RADIATION AND ISOTOPES, 2016, 117 : 2 - 7
  • [3] Spectra and neutron dosimetry inside a PET cyclotron vault room
    Vega-Carrillo, Hector Rene
    Mendez, Roberto
    Iniguez, Maria Pilar
    Marti-Climent, Joseph
    Penuelas, Ivan
    Barquero, Raquel
    [J]. MEDICAL PHYSICS, 2006, 854 : 203 - +
  • [4] Neutron energy spectra inside a PET cyclotron vault room
    Vega-Carrillo, HR
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 463 (1-2): : 375 - 386
  • [5] Neutron Spectra in a 15 MV LINAC
    Vega-Carrillo, H. R.
    Chu, Wei-Han
    Tung, Chuan-Jong
    Lan, Jen-Hong
    [J]. ELEVENTH MEXICAN SYMPOSIUM ON MEDICAL PHYSICS, 2010, 1310 : 158 - +
  • [6] Neutron spectra and dosimetric features around an 18 MV Linac accelerator
    Barquero, R
    Mendez, R
    Vega-Carrillo, HR
    Iñiguez, MP
    Edwards, TM
    [J]. HEALTH PHYSICS, 2005, 88 (01): : 48 - 58
  • [7] Neutron spectrum and doses in a 18 MV LINAC
    Hector Rene Vega-Carrillo
    Berenice Hernández-Almaraz
    Victor Martin Hernández-Dávila
    Arturo Ortíz-Hernández
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2010, 283 : 261 - 265
  • [8] Neutron spectrum and doses in a 18 MV LINAC
    Rene Vega-Carrillo, Hector
    Hernandez-Almaraz, Berenice
    Martin Hernandez-Davila, Victor
    Ortiz-Hernandez, Arturo
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2010, 283 (01) : 261 - 265
  • [9] Photoneutron spectra around an 18 MV LINAC
    Hector Rene Vega-Carrillo
    Antonio Baltazar-Raigosa
    [J]. Journal of Radioanalytical and Nuclear Chemistry, 2011, 287 : 323 - 327
  • [10] Photoneutron spectra around an 18 MV LINAC
    Rene Vega-Carrillo, Hector
    Baltazar-Raigosa, Antonio
    [J]. JOURNAL OF RADIOANALYTICAL AND NUCLEAR CHEMISTRY, 2011, 287 (01) : 323 - 327