Clinical outcome, functional outcome and patient satisfaction after cruciate retaining total knee arthroplasty for stiff arthritic knee - A short term outcome study

被引:2
|
作者
Purudappa, Prabhudev Prasad [1 ]
Sharma, Om Prakash [2 ]
Chandrasekharan, Jayadev [3 ]
Sudevan, Prasanth Jayakumari [3 ]
Mounasamy, Varatharaj [4 ]
Sambandam, Senthil Nathan [1 ]
机构
[1] Boston Va Med Ctr, 150 S Huntington Ave, Boston, MA 02130 USA
[2] Essentia Hlth St Marys Detroit Lakes Clin, Dept Orthopaed Surg, 1027 Washington Ave, Detroit Lakes, MN 56501 USA
[3] KG Hosp & Postgrad Med Inst, Dept Orthopaed, Arts Coll Rd, Coimbatore 641018, Tamil Nadu, India
[4] Vcu Med Ctr Ambulatory Care Ctr, 417 North 11th St, Richmond, VA USA
关键词
Stiff knee; Cruciate retaining; Posterior stabilized; POSTOPERATIVE FLEXION; RANGE; MOTION;
D O I
10.1016/j.jor.2019.12.001
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Various authors have shown that Cruciate Retaining (CR) Total Knee Arthroplasty (TKA) has better long-term survivorship compared to Posterior Stabilized (PS), however most arthroplasty surgeons tend to use PS knees in patients with severe deformity and stiffness. There is limited data correlating stiffness and CR versus PS design. The aim of our study was to assess the outcome of CR TKA for patients with stiff arthritic knee. Materials & methods: We evaluated the results of 30 knees with osteoarthritis and inflammatory arthritis and preoperative stiffness (ROM 15-90 degrees), who had been treated with CR TKA with a mean follow up of 2 years. The primary outcome variable measures were improvement in the flexion, flexion deformity (FFD) and overall im- provement in the arc of motion. Patients were also evaluated by Knee Society Score (KSS), WOMAC score and 5-point Likert scale for patient satisfaction. Result: At the time of final follow-up, the mean arc of motion improved from 75 degrees preoperatively to 108 degrees post-operatively and it was statistically significant (p < 0.001). Similar improvement was noted for FFD (15.43 degrees to 0.83 degrees (p < 0.001)), maximum flexion from 90.9 degrees to 109.1 degrees (p < 0.001), KSS clinical from 37.67 to 87.47 (p < 0.001), KSS functional from 58.5 to 93.83 (p < 0.001), WOMAC from 76.73 to 7.63 (p < 0.001). Further, the Likert Scale for patient satisfaction was excellent for 90% of the patients. Conclusion: This study clearly shows that the routine use of PS design for complex stiff knees has questionable scientific intent and standard CR TKA design in stiff knees can produce excellent outcome. Since there is slight preponderance of data pointing towards improved longevity with CR design, it would be a better option for the patients with longer life expectancy.
引用
收藏
页码:6 / 11
页数:6
相关论文
共 50 条
  • [1] A SHORT TERM OUTCOME OF STANDARD CRUCIATE RETAINING ARTHROPLASTY IN PRIMARY OSTEOARTHRITIS OF KNEE
    Sankarlingam, P.
    Pandian, Raja R.
    Vijayaragavan, N.
    INTERNATIONAL JOURNAL OF MEDICAL RESEARCH & HEALTH SCIENCES, 2015, 4 (01): : 130 - 134
  • [2] Differences in outcome after cruciate retaining and posterior stabilized total knee arthroplasty
    Singleton, Neal
    Nicholas, Bryden
    Gormack, Nick
    Stokes, Andrew
    JOURNAL OF ORTHOPAEDIC SURGERY, 2019, 27 (02)
  • [3] Expectation, satisfaction and clinical outcome of patients after total knee arthroplasty
    Becker, Roland
    Doering, Carl
    Denecke, Andreas
    Brosz, Mathias
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2011, 19 (09) : 1433 - 1441
  • [4] Expectation, satisfaction and clinical outcome of patients after total knee arthroplasty
    Roland Becker
    Carl Döring
    Andreas Denecke
    Mathias Brosz
    Knee Surgery, Sports Traumatology, Arthroscopy, 2011, 19
  • [5] Evaluation of the Functional Outcome of Total Knee Arthroplasty Posterior Cruciate Ligament Retaining Versus Sacrificing
    Mageswaran, S.
    Krishna, Anoop
    Sanjeev, P.
    Anandan, Heber
    INTERNATIONAL JOURNAL OF SCIENTIFIC STUDY, 2016, 4 (08) : 176 - 178
  • [6] Clinical outcome and patient satisfaction in aseptic and septic revision total knee arthroplasty
    Wang, CJ
    Hsieh, MC
    Huang, TW
    Wang, JW
    Chen, HS
    Liu, CY
    KNEE, 2004, 11 (01): : 45 - 49
  • [7] Outcome after total knee arthroplasty in hemophilic patients with stiff knees
    Strauss, Andreas C.
    Wessling, Martin
    Goldmann, Georg
    Mueller, Marcus C.
    Placzek, Richard
    Seuser, Axel
    Oldenburg, Johannes
    Wirtz, Dieter C.
    Pennekamp, Peter H.
    HAEMOPHILIA, 2014, 20 : 66 - 66
  • [8] Outcome after total knee arthroplasty in haemophilic patients with stiff knees
    Strauss, A. C.
    Schmolders, J.
    Friedrich, M. J.
    Pflugmacher, R.
    Mueller, M. C.
    Goldmann, G.
    Oldenburg, J.
    Pennekamp, P. H.
    HAEMOPHILIA, 2015, 21 (04) : E300 - E305
  • [9] Cemented Total Knee Arthroplasty- A Short Term Clinical, Functional Assessment and Outcome Analysis
    Kandasamy, Meenakshi Sundaram
    Kandaswamy, Kandaswamy Ganesh Shankar
    Rajaram, Sathish Kumar
    Kurup, Vijayan Gopala Krishna
    JOURNAL OF EVOLUTION OF MEDICAL AND DENTAL SCIENCES-JEMDS, 2020, 9 (03): : 138 - 141
  • [10] Asynchronous Bilateral Total Knee Arthroplasty: Predictors of the Functional Outcome and Patient Satisfaction for the Second Knee Replacement
    Clement, Nicholas D.
    Merrie, Katie L.
    Weir, David J.
    Holland, James P.
    Deehan, David J.
    JOURNAL OF ARTHROPLASTY, 2019, 34 (12): : 2950 - 2956