Efficacy of anterior cervical fusion: Comparison of titanium cages, polyetheretherketone (PEEK) cages and autogenous bone grafts

被引:100
|
作者
Chou, Yu-Cheng [1 ,2 ]
Chen, Der-Cherng [2 ]
Hsieh, Wanhua Annie [4 ]
Chen, Wu-Fu [5 ]
Yen, Pao-Sheng [3 ]
Harnod, Tomor [2 ]
Chiou, Tsung-Lang [2 ]
Chang, Yuh-Lin [2 ]
Su, Chain-Fa [2 ]
Lin, Shinn-Zong [1 ,2 ]
Chen, Shin-Yuan [1 ,2 ]
机构
[1] Buddhist Tzu Chi Gen Hosp, Div Funct Neurosci, Hualien, Taiwan
[2] Buddhist Tzu Chi Gen Hosp Univ, Neuromed Sci Ctr, Dept Neurosurg, Hualien, Taiwan
[3] Buddhist Tzu Chi Gen Hosp, Dept Med Imaging, Hualien, Taiwan
[4] Buddhist Tzu Chi Univ, Inst Aboriginal Hlth, Hualien, Taiwan
[5] Chung Gung Mem Hosp, Kaohsiung, Taiwan
关键词
Anterior cervical fusion; Cage; Titanium; PEEK; Tri-cortical autogeneous bone graft;
D O I
10.1016/j.jocn.2007.05.016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
This retrospective study was designed to analyze and compare the efficacy and outcomes of anterior cervical fusion using titanium cages, polyetheretherketone (PEEK) cages and autogenous tricortical bone grafts. Fifty-five patients who underwent segmental anterior discectomy with a follow-up period up to 12 months enrolled in this study. They were divided into three groups: titanium cage with biphasic calcium phosphate ceramic (Triosite; Zimmer, Berlin, Germany) in group A (n = 27); PEEK cage with Triosite in group B (n = 9); and autogenous tricortical iliac crest bone graft in group C (n = 19). The fusion rates after 6 months were 37.21% in group A, 93.3% in group B, and 84.85% in group C. The fusion rates after 6 months were 37.21% in group A, 93.3% in group B, and 84.85% in group C. The fusion rates after 1 year in groups A, B, and C were 46.51% 100% and 100% respectively. The PEEK cage is a viable alternative to autogenous tricortical bone grafts in anterior cervical fusion. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1240 / 1245
页数:6
相关论文
共 50 条
  • [1] Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages
    Mario Cabraja
    Soner Oezdemir
    Daniel Koeppen
    Stefan Kroppenstedt
    [J]. BMC Musculoskeletal Disorders, 13
  • [2] Anterior cervical discectomy and fusion: Comparison of titanium and polyetheretherketone cages
    Cabraja, Mario
    Oezdemir, Soner
    Koeppen, Daniel
    Kroppenstedt, Stefan
    [J]. BMC MUSCULOSKELETAL DISORDERS, 2012, 13
  • [3] Outcomes of Interbody Fusion Cages Used in 1 and 2-levels Anterior Cervical Discectomy and Fusion Titanium Cages Versus Polyetheretherketone (PEEK) Cages
    Niu, Chi-Chien
    Liao, Jen-Chung
    Chen, Wen-Jer
    Chen, Lih-Huei
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2010, 23 (05): : 310 - 316
  • [4] Polyetheretherketone Interbody Cages Versus Autogenous Iliac Crest Bone Grafts With Anterior Fixation for Cervical Disc Disease
    Landriel, Federico A.
    Hem, Santiago
    Goldschmidt, Ezequiel
    Ajler, Pablo
    Vecchi, Eduardo
    Carrizo, Antonio
    [J]. JOURNAL OF SPINAL DISORDERS & TECHNIQUES, 2013, 26 (02): : 61 - 67
  • [5] Radiological and clinical outcomes in patients undergoing anterior cervical discectomy and fusion: Comparing titanium and PEEK (polyetheretherketone) cages
    Junaid, Muhammad
    Rashid, Mamoon Ur
    Bukhari, Syed Sarmad
    Ahmed, Mamoon
    [J]. PAKISTAN JOURNAL OF MEDICAL SCIENCES, 2018, 34 (06) : 1412 - 1417
  • [6] Distractable titanium cages versus PEEK cages versus iliac crest bone grafts for the replacement of cervical vertebrae
    Koenig, Stefan Alexander
    Spetzger, Uwe
    [J]. MINIMALLY INVASIVE THERAPY & ALLIED TECHNOLOGIES, 2014, 23 (02) : 102 - 105
  • [7] Anterior cervical interbody fusion with titanium cages
    Dons, K
    Gjerris, F
    [J]. RIVISTA DI NEURORADIOLOGIA, 1999, 12 : 121 - 123
  • [8] PEEK Cages versus Titanium-Coated PEEK Cages in Single-Level Anterior Cervical Fusion: A Randomized Controlled Study
    Schroeder, Johannes
    Kampulz, Thomas
    Bajaj, Sonunandita K.
    Hellwig, Arnd Georg
    Winking, Michael
    [J]. JOURNAL OF NEUROLOGICAL SURGERY PART A-CENTRAL EUROPEAN NEUROSURGERY, 2024, 85 (03) : 262 - 268
  • [9] Polyetheretherketone (PEEK) cages in cervical applications: a systematic review
    Kersten, Roel Frederik Mark Raymond
    van Gaalen, Steven M.
    de Gast, Arthur
    Oner, F. Cumhur
    [J]. SPINE JOURNAL, 2015, 15 (06): : 1446 - 1460
  • [10] PEEK versus titanium-coated PEEK cervical cages: fusion rate
    Bartosz Godlewski
    Adam Bebenek
    Maciej Dominiak
    Grzegorz Karpinski
    Piotr Cieslik
    Tomasz Pawelczyk
    [J]. Acta Neurochirurgica, 2022, 164 : 1501 - 1507