Effect of the nonlinearity of the CCD in Fourier transform profilometry on spectrum overlapping and measurement accuracy

被引:9
|
作者
Qiao Nao-Sheng [1 ,2 ]
Zou Bei-Ji [1 ]
机构
[1] Cent S Univ, Sch Informat Sci & Engn, Changsha 410083, Hunan, Peoples R China
[2] Hunan Univ Arts & Sci, Sch Phys & Elect, Changde 415000, Peoples R China
基金
中国国家自然科学基金;
关键词
spectra overlapping; measurement accuracy; nonlinearity of CCD; Fourier transform profilometry;
D O I
10.1088/1674-1056/22/1/014203
中图分类号
O4 [物理学];
学科分类号
0702 ;
摘要
In Fourier transform profilometry (FTP), we must restrain spectrum overlapping caused by the nonlinearity of the charge coupled device (CCD) and increase the measurement accuracy of the object shape. Firstly, the causes of producing higher-order spectrum components and inducing spectrum overlapping are analysed theoretically, and a simple physical explanation and analytical deduction are given. Secondly, aiming to suppress spectrum overlapping and improve measurement accuracy, the influence of spatial carrier frequency of projection grating on them is analysed. A method of increasing the spatial carrier frequency of projection grating to restrain or reduce the spectrum overlapping significantly is proposed. We then analyze the mechanism of how the spectrum overlapping is reduced. Finally, the simulation results and experimental measurements verify the correction of the proposed theory and method.
引用
收藏
页数:6
相关论文
共 50 条
  • [1] Effect of the nonlinearity of the CCD in Fourier transform profilometry on spectrum overlapping and measurement accuracy
    乔闹生
    邹北骥
    Chinese Physics B, 2013, 22 (01) : 237 - 242
  • [2] Effect of Fourier transform profilometry by sampling of CCD
    Department of Physics and Electronics, Hunan University of Arts and Science, Changde 415000, China
    不详
    Guangxue Jishu, 2007, 6 (915-917):
  • [3] Error analysis about CCD sampling in Fourier transform profilometry
    Chen, Wenjing
    Li, Manhai
    Su, Xianyu
    OPTIK, 2009, 120 (13): : 652 - 657
  • [4] Fourier transform profilometry of tilted measurement system
    Xu Jian-Liang
    Wang Min
    Pan Hui
    Liu Xiao-Hui
    Qi Xiao-Li
    Xu Si-Xiang
    ACTA PHYSICA SINICA, 2011, 60 (07)
  • [5] Elimination of nonlinearity in modulation measurement profilometry by Wavelet Transform
    Zhong, Min
    Chen, Feng
    Xiao, Chao
    Yang, Yu
    OPTIK, 2018, 168 : 488 - 502
  • [6] Method for eliminating zero spectrum in Fourier transform profilometry
    Chen, WJ
    So, XY
    Cao, Y
    Zhang, Q
    Xiang, L
    OPTICS AND LASERS IN ENGINEERING, 2005, 43 (11) : 1267 - 1276
  • [7] Global measurement of water waves by Fourier transform profilometry
    Pablo Javier Cobelli
    Agnès Maurel
    Vincent Pagneux
    Philippe Petitjeans
    Experiments in Fluids, 2009, 46
  • [8] Global measurement of water waves by Fourier transform profilometry
    Cobelli, Pablo Javier
    Maurel, Agnes
    Pagneux, Vincent
    Petitjeans, Philippe
    EXPERIMENTS IN FLUIDS, 2009, 46 (06) : 1037 - 1047
  • [9] Effect of CCD nonlinearity on spectrum distribution
    Qiao, Naosheng
    OPTIK, 2016, 127 (20): : 8607 - 8612
  • [10] Method for Improving Measurement Accuracy of Wavelet Transform Profilometry
    Zhang Cheng
    Chen Wenjing
    ACTA OPTICA SINICA, 2018, 38 (07)