Particulate corrosion and wear products of metal implants are increasingly becoming topics of interest, due to the cascade of biological and biomechanical events they induce. The impairment of skeletal muscle microcirculation by fretting corrosion particles may have profound consequences. We therefore studied in vivo leukocyte-endothelial cell interaction in skeletal muscle after confrontation with characterized titanium and stainless steel fretting corrosion particles, and compared these results with those of the bulk materials. Using the hamster dorsal skinfold chamber preparation and intravital microscopy, we could demonstrate that stainless steel induces a more pronounced inflammatory answer in contrast to the implant material titanium. However, we were not able to show a general benefit of bulk vs. debris. Overall, the study suggests that not only the bulk properties of orthopaedic implants, but also the microcirculatory implications of inevitable wear debris, may play a role in determining biocompatibility and ultimately longevity of an implant. The skinfold chamber is a feasible and versatile model for observation of the dynamic process of microvascular response after foreign-body implantation, and offers much perspective. (C) 2001 Kluwer Academic Publishers.
引用
收藏
页码:1057 / 1062
页数:6
相关论文
共 50 条
  • [1] Implications of orthopedic fretting corrosion particles on skeletal muscle microcirculation
    C. N. Kraft
    B. Burian
    O. Diedrich
    M. A. Wimmer
    Journal of Materials Science: Materials in Medicine, 2001, 12 : 1057 - 1062
  • [2] Orthopedic implant fretting corrosion
    Hallab, NJ
    Jacobs, JJ
    CORROSION REVIEWS, 2003, 21 (2-3) : 183 - 213
  • [3] Orthopedic implant fretting corrosion
    Hallab, Nadim James
    Jacobs, Joshua J.
    Corrosion Reviews, 2003, 21 (2-3): : 183 - 213
  • [4] FRETTING CORROSION ON ORTHOPEDIC IMPLANTS
    COHEN, J
    LINDENBA.B
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1968, (61) : 167 - &
  • [5] FRETTING CORROSION IN ORTHOPEDIC ALLOYS
    COOK, SD
    GIANOLI, GJ
    CLEMOW, AJT
    HADDAD, RJ
    BIOMATERIALS MEDICAL DEVICES AND ARTIFICIAL ORGANS, 1983, 11 (04): : 281 - 292
  • [6] INVITRO STUDIES OF FRETTING CORROSION OF ORTHOPEDIC MATERIALS
    BROWN, SA
    HUGHES, PJ
    MERRITT, K
    JOURNAL OF ORTHOPAEDIC RESEARCH, 1988, 6 (04) : 572 - 579
  • [7] Microcirculation in skeletal muscle
    Hudlicka, Olga
    MLTJ-MUSCLES LIGAMENTS AND TENDONS JOURNAL, 2011, 1 (01): : 3 - 11
  • [8] SKELETAL-MUSCLE MICROCIRCULATION
    SLAAF, DW
    TANGELDER, GJ
    RENEMAN, RS
    EXPERIENTIA, 1984, 40 (11): : 1296 - 1296
  • [9] The microcirculation of skeletal muscle in aging
    Payne, GW
    Bearden, SE
    MICROCIRCULATION, 2006, 13 (04) : 275 - 277
  • [10] AN SEM CORROSION CAST STUDY OF PERICYTE LOCALIZATION AND ROLE IN MICROCIRCULATION OF SKELETAL-MUSCLE
    GAUDIO, E
    PANNARALE, L
    MARINOZZI, G
    ANGIOLOGY, 1985, 36 (07) : 458 - 464