Hit-Time and Hit-Position Reconstruction in Strips of Plastic Scintillators Using Multithreshold Readouts

被引:2
|
作者
Sharma, N. G. [1 ]
Silarski, M. [1 ]
Chhokar, J. [1 ]
Czerwinski, E. [1 ]
Curceanu, C. [2 ]
Dulski, K. [1 ]
Farbaniec, K. [1 ]
Gajos, A. [1 ]
Del Grande, R. [2 ]
Gorgol, M. [3 ]
Hiesmayr, B. C. [4 ]
Jasinska, B. [3 ]
Kacprzak, K. [1 ]
Kaplon, L. [1 ]
Kisielewska, D. [1 ]
Klimaszewski, K. [6 ]
Korcyl, G. [1 ]
Kowalski, P. [6 ]
Krawczyk, N. [1 ]
Krzemien, W. [5 ]
Kozik, T. [1 ]
Kubicz, E. [1 ]
Mohammed, M. [1 ,7 ]
Niedzwiecki, Sz [1 ]
Palka, M. [1 ]
Pawlik-Niedzwiecka, M. [1 ]
Raczynski, L. [6 ]
Raj, J. [1 ]
Sharma, S. [1 ]
Shivani, S. [1 ]
Shopa, R. Y. [6 ]
Skurzok, M. [1 ]
Wislicki, W. [6 ]
Zgardzinska, B. [3 ]
Moskal, P. [1 ]
机构
[1] Jagiellonian Univ, Fac Phys Astron & Appl Comp Sci, PL-30348 Krakow, Poland
[2] Ist Nazl Fis Nucl, Lab Nazl Frascati, I-00044 Frascati, Italy
[3] Marie Curie Sklodowska Univ, Inst Phys, PL-20031 Lublin, Poland
[4] Univ Vienna, Fac Phys, A-1090 Vienna, Austria
[5] Natl Ctr Nucl Res, High Energy Phys Div, PL-05400 Otwock, Poland
[6] Natl Ctr Nucl Res, Dept Complex Syst, PL-05400 Otwock, Poland
[7] Univ Mosul, Coll Educ Pure Sci, Dept Phys, Mosul 41002, Iraq
基金
奥地利科学基金会;
关键词
J-PET detector; Mahalanobis distance; medical imaging; spatial resolution; TOF resolution; J-PET; RESOLUTION; SIGNALS; SENSITIVITY; DETECTORS; DIGITIZER; LIBRARY;
D O I
10.1109/TRPMS.2020.2990621
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
In this article, a new method for the reconstruction of hit-position and hit-time of photons in long scintillator detectors is investigated. This article is motivated by the recent development of the positron emission tomography scanners based on plastic scintillators. The proposed method constitutes a new way of signal processing in multivoltage-technique. It is based on the determination of the degree of similarity between the registered signals and the synchronized model signals stored in a library. The library was established for a set of well-defined hit-positions along the length of the scintillator. The Mahalanobis distance was used as a measure of similarity between the two compared signals. The method was validated on the experimental data measured using two-strips J-PET prototype with dimensions of 5 x 9 x 300 mm(3). The obtained time-of-flight (TOF) and spatial resolutions amount to 325 ps (FWHM) and 25 mm (FWHM), respectively. The TOF resolution was also compared to the results of an analogous study done using the linear fitting method. The best TOF resolution was obtained with this method at four predefined threshold levels which was comparable to the resolution achieved from the Mahalanobis distance at two predefined threshold levels. Although the algorithm of the linear fitting method is much simpler to apply than the Mahalanobis method, the application of the Mahalanobis distance requires a lower number of applied threshold levels and, hence, decreases the costs of electronics used in PET scanner.
引用
收藏
页码:528 / 537
页数:10
相关论文
共 4 条
  • [1] Novel method for hit-position reconstruction using voltage signals in plastic scintillators and its application to Positron Emission Tomography
    Raczynski, L.
    Moskal, P.
    Kowalski, P.
    Wislicki, W.
    Bednarski, T.
    Bialas, P.
    Czerwinski, E.
    Kaplon, L.
    Kochanowski, A.
    Korcyl, G.
    Kowal, J.
    Kozik, T.
    Krzemien, W.
    Kubicz, E.
    Molenda, M.
    Moskal, I.
    Niedzwiecki, Sz.
    Palka, M.
    Pawlik-Niedzwiecka, M.
    Rudy, Z.
    Salabura, R.
    Sharma, N. G.
    Silarski, M.
    Slomski, A.
    Smyrski, J.
    Strzelecki, A.
    Wieczorek, A.
    Zielinski, M.
    Zon, N.
    [J]. NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2014, 764 : 186 - 192
  • [2] Reconstruction of hit time and hit position of annihilation quanta in the J-PET detector using the Mahalanobis distance
    Sharma, Neha Gupta
    Silarski, Michal
    Bednarski, Tomasz
    Bialas, Piotr
    Czerwinski, Eryk
    Gajos, Aleksander
    Gorgol, Marek
    Jasinska, Bozena
    Kaminska, Daria
    Kaplon, Lukasz
    Korcyl, Grzegorz
    Kowalski, Pawel
    Kozik, Tomasz
    Krzemien, Wojciech
    Kubicz, Ewelina
    Niedzwiecki, Szymon
    Palka, Marek
    Raczynski, Lech
    Rudy, Zbigniew
    Rundel, Oleksandr
    Slomski, Artur
    Strzelecki, Adam
    Wieczorek, Anna
    Wislicki, Wojciech
    Zielinski, Marcin
    Zgardzinska, Bozena
    Moskal, Pawel
    [J]. NUKLEONIKA, 2015, 60 (04) : 765 - 769
  • [3] Hit Time and Hit Position Reconstruction in the J-PET Detector Based on a Library of Averaged Model Signals
    Moskal, P.
    Sharma, N. G.
    Silarski, M.
    Bednarski, T.
    Bialas, P.
    Bulka, J.
    Czerwinski, E.
    Gajos, A.
    Kaminska, D.
    Kaplon, L.
    Kochanowski, A.
    Korcyl, G.
    Kowal, J.
    Kowalski, P.
    Kozik, T.
    Krzemien, W.
    Kubicz, E.
    Niedzwiecki, Sz
    Palka, M.
    Raczynski, L.
    Rudy, Z.
    Rundel, O.
    Salabura, P.
    Slomski, A.
    Smyrski, J.
    Strzelecki, A.
    Wieczorek, A.
    Wislicki, W.
    Wochlik, I.
    Zielinski, M.
    Zon, N.
    [J]. ACTA PHYSICA POLONICA A, 2015, 127 (05) : 1495 - 1499
  • [4] Multi-hit, position-sensitive, time-of-flight spectrometry using a modified-backgammon-weighed-capacitor anode
    Rajgara, FA
    Mathur, D
    Nishide, T
    Kitamura, T
    Shiromaru, H
    Achiba, Y
    Kobayashi, N
    [J]. INTERNATIONAL JOURNAL OF MASS SPECTROMETRY, 2002, 215 (1-3) : 151 - 162