Comparison of the iScreen and the MTI photoscreeners for the detection of amblyopia risk factors in children

被引:15
|
作者
Silbert, David I. [1 ]
Arnold, Robert W. [2 ]
Matta, Noelle S. [1 ]
机构
[1] Family Eye Grp, Dept Vis Sci, Lancaster, PA 17601 USA
[2] Ophthalm Associates, Anchorage, AK USA
来源
JOURNAL OF AAPOS | 2013年 / 17卷 / 01期
关键词
AMBLYOGENIC FACTORS;
D O I
10.1016/j.jaapos.2012.09.015
中图分类号
R77 [眼科学];
学科分类号
100212 ;
摘要
BACKGROUND The iScreen and Medical Technology and Innovations, Inc, (MTI) photoscreeners objectively screen for amblyopia risk factors in children. The MTI photoscreener has been extensively validated as a device that objectively screens for amblyopia risk factors in children, but limited availability of the instant film it uses may soon render it obsolete. More recently the iScreen photoscreener has been introduced. This device captures images digitally and transmits them electronically to be interpreted. We compared the newer iScreen's ability to detect amblyopia risk factors in children with the established MTI photoscreener. METHODS The medical records of consecutive subjects screened by both the iScreen and MTI photoscreeners on the same day were retrospectively reviewed. The iScreen images were analyzed by the device's central interpretation center; MTI images were analyzed by an expert masked examiner using the delta crescent method. Referrals by both instruments were compared to the results of cycloplegic examination as per the American Association for Pediatric Ophthalmology and Strabismus 2003 referral criteria. RESULTS A total of 169 children were included in the study. Of these, 107 (63%) were found to have amblyopia risk factors. The iScreen was found to have an accuracy rate of 81%, sensitivity of 87%, and specificity of 76%. The MTI was found to have an accuracy rate of 81%, sensitivity of 81%, and specificity of 81%. CONCLUSIONS The iScreen and MTI performed similarly in detecting amblyopia risk factors when compared to a comprehensive pediatric ophthalmology examination. (J AAPOS 2013; 17:34-37)
引用
收藏
页码:34 / 37
页数:4
相关论文
共 50 条
  • [1] Comparison Between the plusoptiX and MTI Photoscreeners
    Matta, Noelle S.
    Arnold, Robert W.
    Singman, Eric L.
    Silbert, David I.
    [J]. ARCHIVES OF OPHTHALMOLOGY, 2009, 127 (12) : 1591 - 1595
  • [2] Cost-Effectiveness of Photoscreeners in Screening at-Risk Amblyopia in Indian Children
    Murali, Kaushik
    Vidhya, C.
    Murthy, Sowmya Raveendra
    Mallapa, Sowmya
    [J]. INDIAN JOURNAL OF PUBLIC HEALTH, 2022, 66 (02) : 171 - 175
  • [3] Comparison of photoscreening and autorefractive screening for the detection of amblyopia risk factors in children under 3 years of age
    Kara, Caner
    Petricli, Ikbal Seza
    [J]. JOURNAL OF AAPOS, 2020, 24 (01): : 20.e1 - 20.e8
  • [4] Performance of the Plusoptix vision screener for the detection of amblyopia risk factors in children
    Matta, Noelle S.
    Singman, Eric L.
    Silbert, David I.
    [J]. JOURNAL OF AAPOS, 2008, 12 (05): : 490 - 492
  • [5] Performance of the Spot vision screener for the detection of amblyopia risk factors in children
    Silbert, David I.
    Matta, Noelle S.
    [J]. JOURNAL OF AAPOS, 2014, 18 (02): : 169 - 172
  • [6] Comparative Validation of PlusoptiX and AI-Optic Photoscreeners in Children with High Amblyopia Risk Factor Prevalence
    Arnold, Robert W.
    [J]. CLINICAL OPHTHALMOLOGY, 2022, 16 : 2639 - 2650
  • [7] Advantages, limitations, and diagnostic accuracy of photoscreeners in early detection of amblyopia: a review
    Sanchez, Irene
    Ortiz-Toquero, Sara
    Martin, Raul
    de Juan, Victoria
    [J]. CLINICAL OPHTHALMOLOGY, 2016, 10 : 1365 - 1373
  • [8] Performance of Four New Photoscreeners on Pediatric Patients With High Risk Amblyopia
    Arnold, Robert W.
    Armitage, M. Diane
    [J]. JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2014, 51 (01) : 46 - 52
  • [9] A Comparison of Three Different Photoscreeners in Children
    Teberik, Kuddusi
    Eski, Mehmet Tahir
    Kaya, Murat
    Ankarali, Handan
    [J]. JOURNAL OF PEDIATRIC OPHTHALMOLOGY & STRABISMUS, 2018, 55 (05) : 306 - +
  • [10] AMBLYOPIA PREVALENCE AND RISK FACTORS IN PRESCHOOL CHILDREN
    Pai, Amy
    Burlutsky, George
    Mitchell, Paul
    [J]. CLINICAL AND EXPERIMENTAL OPHTHALMOLOGY, 2011, 39 : 57 - 57